Manufacturer: SunSpark Technology Inc Registry: CEC Verified Engineering Specification

SunSpark Technology Inc SST-285M is a 285.0 W STC (257.5 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.32% efficiency, 39.28 V Voc at 25 C, and 43.97 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
257.5 W
Voc @ 25C
39.28 V
Efficiency
17.32%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunSpark Technology Inc SST-285M Compare Against Peer CEC Listings?

Solar engineering breakdown for SunSpark Technology Inc SST-285M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from SunSpark Technology Inc and peers, SunSpark Technology Inc SST-285M stands 125.0 W below the 410.0 W Mono-c-Si median and typical 90.4% PTC-to-STC thermal output (257.5 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Lower 39.28 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does SunSpark Technology Inc SST-285M Fall Across Listed CEC Models?

Distribution marker showing SunSpark Technology Inc SST-285M (285.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunSpark Technology Inc SST-285M (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunSpark Technolog: 285.0 W

What Dataset Percentiles Define SunSpark Technology Inc SST-285M?

Dataset percentiles tracking SunSpark Technology Inc SST-285M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

SunSpark Technology Inc SST-285M Engineering BenchmarksPercentile comparison of SunSpark Technology Inc SST-285M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.4%Module Efficiency17.32%

What Do the Dataset Ranks Show for SunSpark Technology Inc SST-285M?

Benchmark highlights for SunSpark Technology Inc SST-285M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,025

17.32% Aperture Efficiency

Power density 173.3 W/m2 (2.59 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.97 V at -10 C (571.6 V string) and 45.31 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 47.7 m2 (513 sq ft) producing 7,468 W PTC; NEC 690.8 OCPD floor is 14.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.28 * (1 + (-0.341/100) * (-10 - 25)) = 43.97 V | OCPD = 1.56 * 9.44 = 14.73 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-285M: Voc=39.28 V, beta_Voc=-0.341%/C, Isc=9.44 A, STC=285.0 W, Area=1.645 m2.

Result: 13 panels max on 600 V (571.6 V); 29 panels for 8 kW (513 sq ft).

What Are the Published CEC Specifications for SunSpark Technology Inc SST-285M?

Official CEC datasheet figures for SunSpark Technology Inc SST-285M (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-285M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 257.5 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.28 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.44 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.92 V / 8.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.341 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.32% (1.645 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many SunSpark Technology Inc SST-285M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SunSpark Technology Inc SST-285M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 390 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 513 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 637 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

Consolidated SunSpark Technology Inc wattage variants sharing the SunSpark Technology Inc SST-285M mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SunSpark Technology Inc SST-285M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunSpark Technology Inc SST-275M 275.0 W 248.1 W 38.88 V 31.7 V 16.72%
SunSpark Technology Inc SST-280M 280.0 W 252.8 W 39.08 V 31.81 V 17.02%
SunSpark Technology Inc SST-285M 285.0 W 257.5 W 39.28 V 31.92 V 17.32%
SunSpark Technology Inc SST-290M 290.0 W 262.1 W 39.46 V 32.03 V 17.63%
SunSpark Technology Inc SST-295M 295.0 W 266.8 W 39.64 V 32.14 V 17.93%

How Many SunSpark Technology Inc SST-285M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SunSpark Technology Inc SST-285M (43.97 V at 14 F).

Computed from Voc=39.28V and beta_Voc=-0.341%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.31 V 13 panels 589.0 V 22 panels
-10 C (14 F) 43.97 V 13 panels 571.6 V 22 panels
0 C (32 F) 42.63 V 14 panels 596.8 V 23 panels
25 C (77 F STC) 39.28 V 15 panels 589.2 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-285M?

Competing CEC solar panels closest to SunSpark Technology Inc SST-285M in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM285M-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM285M-60
Bluesun Solar Energy Tech CoLtd
285.0 W Tie (0 W) 39.25 V 17.52% 90.1%
DuCal Solar Technology LLC DST285M-60
DuCal Solar Technology LLC
285.0 W Tie (0 W) 39.25 V 17.52% 90.1%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
285.0 W Tie (0 W) 39.18 V 17.69% 91.4%
Centrosolar America EM60 285BW
Centrosolar America
285.0 W Tie (0 W) 39.18 V 17.69% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-285M?

Evaluate SunSpark Technology Inc SST-285M (285.0 W STC, 39.28 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-285M reaches 45.31 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 513 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (513 sq ft).
  • 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-285M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunSpark Technology Inc SST-285M 8 kW Residential Fit

Needs 29 modules (513 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM285M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 257.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-285M by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SunSpark Technology Inc SST-285M?

Multiplying SunSpark Technology Inc SST-285M's 9.44 A short-circuit current by 1.56 equals 14.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can SunSpark Technology Inc SST-285M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.97 V cold Voc at 14 F and handles 9.44 A Isc; string inverters cap SunSpark Technology Inc SST-285M at 13 panels on 600 V.

Is SunSpark Technology Inc SST-285M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunSpark Technology Inc SST-285M rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.