Sungen Power LLC SS-455-60IIMJ is a 455.0 W STC (428.1 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 20.97% efficiency, 41.38 V Voc at 25 C, and 45.06 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 428.1 W
- Voc @ 25C
- 41.38 V
- Efficiency
- 20.97%
How Does Sungen Power LLC SS-455-60IIMJ Compare Against Peer CEC Listings?
Engineering position of Sungen Power LLC SS-455-60IIMJ (455.0 W STC) vs. CertainTeed CTM10455HC11-06 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Sungen Power LLC SS-455-60IIMJ pairs strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677) with 41.38 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,706 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CTM10455HC11-06 offers a 455.0 W alternative.
Where Does Sungen Power LLC SS-455-60IIMJ Fall Across Listed CEC Models?
Plots Sungen Power LLC SS-455-60IIMJ at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Sungen Power LLC SS-455-60IIMJ?
Benchmarks Sungen Power LLC SS-455-60IIMJ on STC wattage, thermal PTC/STC retention, and 20.97 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Sungen Power LLC SS-455-60IIMJ?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Sungen Power LLC SS-455-60IIMJ by Sungen Power LLC.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.97% Aperture Efficiency
Power density 209.7 W/m2 (1.06 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.06 V at -10 C (585.8 V string) and 46.11 V at -20 C (13 max).
18 Panels = 8,190 W STC
Occupies 39.1 m2 (420 sq ft) producing 7,706 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.38 * (1 + (-0.254/100) * (-10 - 25)) = 45.06 V | OCPD = 1.56 * 13.92 = 21.72 A
Inputs from CEC Modules.csv for Sungen Power LLC SS-455-60IIMJ: Voc=41.38 V, beta_Voc=-0.254%/C, Isc=13.92 A, STC=455.0 W, Area=2.17 m2.
Result: 13 panels max on 600 V (585.8 V); 18 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Sungen Power LLC SS-455-60IIMJ?
Laboratory test ratings recorded for Sungen Power LLC SS-455-60IIMJ (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 428.1 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.38 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.56 V / 13.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.97% (2.17 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sungen Power LLC SS-455-60IIMJ Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for Sungen Power LLC SS-455-60IIMJ.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 327 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 420 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 514 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Sungen Power LLC Series?
Sibling wattage bins and frame colors grouped with Sungen Power LLC SS-455-60IIMJ under Sungen Power LLC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Sungen Power LLC SS-450-60IIMJ | 450.0 W | 423.2 W | 41.13 V | 34.38 V | 20.74% |
| Sungen Power LLC SS-455-60IIMJ | 455.0 W | 428.1 W | 41.38 V | 34.56 V | 20.97% |
| Sungen Power LLC SS-460-60IIMJ | 460.0 W | 432.9 W | 41.61 V | 34.82 V | 21.2% |
How Many Sungen Power LLC SS-455-60IIMJ Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Sungen Power LLC SS-455-60IIMJ (beta_Voc -0.254%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.11 V | 13 panels | 599.4 V | 21 panels |
| -10 C (14 F) | 45.06 V | 13 panels | 585.8 V | 22 panels |
| 0 C (32 F) | 44.01 V | 13 panels | 572.1 V | 22 panels |
| 25 C (77 F STC) | 41.38 V | 14 panels | 579.3 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Sungen Power LLC SS-455-60IIMJ?
Closest cross-brand CEC competitors to Sungen Power LLC SS-455-60IIMJ matched near 455.0 W STC and 41.38 V Voc, led by CertainTeed CTM10455HC11-06.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10455HC11-06 CertainTeed |
455.0 W | Tie (0 W) | 41.33 V | 21.06% | 93.8% |
| Energate Energy Inc EG-120L455W Energate Energy Inc |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| Energate Enerji retim San A EG-120L455W Energate Enerji retim San A |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | Tie (0 W) | 41.3 V | 21.26% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Sungen Power LLC SS-455-60IIMJ?
Evaluate Sungen Power LLC SS-455-60IIMJ (455.0 W STC, 41.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sungen Power LLC SS-455-60IIMJ reaches 46.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sungen Power LLC SS-455-60IIMJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sungen Power LLC SS-455-60IIMJ 8 kW Residential Fit
Needs 18 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10455HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 428.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sungen Power LLC SS-455-60IIMJ by Sungen Power LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sungen Power LLC SS-455-60IIMJ?
Multiplying Sungen Power LLC SS-455-60IIMJ's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Sungen Power LLC SS-455-60IIMJ pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.06 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap Sungen Power LLC SS-455-60IIMJ at 13 panels on 600 V.
Is Sungen Power LLC SS-455-60IIMJ eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sungen Power LLC SS-455-60IIMJ rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)