Sonali Energees USA LLC SS-420W-m72H is a 420.0 W STC (392.5 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.0% efficiency, 49.8 V Voc at 25 C, and 54.61 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 392.5 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 19.0%
How Does Sonali Energees USA LLC SS-420W-m72H Compare Against Peer CEC Listings?
Solar engineering breakdown for Sonali Energees USA LLC SS-420W-m72H: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Sonali Energees USA LLC and peers, Sonali Energees USA LLC SS-420W-m72H stands 10.0 W above the 410.0 W Mono-c-Si median and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Sizing 6 kW (15 panels) to 10 kW (24 panels) yields $1,577-$2,523/yr in baseline US bill offset. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Sonali Energees USA LLC SS-420W-m72H Fall Across Listed CEC Models?
Distribution marker showing Sonali Energees USA LLC SS-420W-m72H (420.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Sonali Energees USA LLC SS-420W-m72H?
Dataset percentiles tracking Sonali Energees USA LLC SS-420W-m72H power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Sonali Energees USA LLC SS-420W-m72H?
Benchmark highlights for Sonali Energees USA LLC SS-420W-m72H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.0% Aperture Efficiency
Power density 190.0 W/m2 (0.91 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.61 V at -10 C (546.1 V string) and 55.99 V at -20 C (10 max).
20 Panels = 8,400 W STC
Occupies 44.2 m2 (476 sq ft) producing 7,850 W PTC; NEC 690.8 OCPD floor is 17.58 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.276/100) * (-10 - 25)) = 54.61 V | OCPD = 1.56 * 11.27 = 17.58 A
Inputs from CEC Modules.csv for Sonali Energees USA LLC SS-420W-m72H: Voc=49.8 V, beta_Voc=-0.276%/C, Isc=11.27 A, STC=420.0 W, Area=2.21 m2.
Result: 10 panels max on 600 V (546.1 V); 20 panels for 8 kW (476 sq ft).
What Are the Published CEC Specifications for Sonali Energees USA LLC SS-420W-m72H?
Official CEC datasheet figures for Sonali Energees USA LLC SS-420W-m72H (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 392.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.2 V / 10.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.276 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.0% (2.21 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sonali Energees USA LLC SS-420W-m72H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Sonali Energees USA LLC SS-420W-m72H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 357 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 476 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 571 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Sonali Energees USA LLC Series?
Consolidated Sonali Energees USA LLC wattage variants sharing the Sonali Energees USA LLC SS-420W-m72H mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Sonali Energees USA LLC SS-415W-m72H | 415.0 W | 387.7 W | 49.6 V | 41.15 V | 18.78% |
| Sonali Energees USA LLC SS-420W-m72H | 420.0 W | 392.5 W | 49.8 V | 41.2 V | 19.0% |
How Many Sonali Energees USA LLC SS-420W-m72H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Sonali Energees USA LLC SS-420W-m72H (54.61 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.99 V | 10 panels | 559.9 V | 17 panels |
| -10 C (14 F) | 54.61 V | 10 panels | 546.1 V | 18 panels |
| 0 C (32 F) | 53.24 V | 11 panels | 585.6 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Sonali Energees USA LLC SS-420W-m72H?
Competing CEC solar panels closest to Sonali Energees USA LLC SS-420W-m72H in nameplate wattage and Voc, starting with DualSun SAS DualSun 420M-144-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | -10.0 W | 49.4 V | 21.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Sonali Energees USA LLC SS-420W-m72H?
Evaluate Sonali Energees USA LLC SS-420W-m72H (420.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sonali Energees USA LLC SS-420W-m72H reaches 55.99 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 476 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (476 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sonali Energees USA LLC SS-420W-m72H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sonali Energees USA LLC SS-420W-m72H 8 kW Residential Fit
Needs 20 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 392.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sonali Energees USA LLC SS-420W-m72H by Sonali Energees USA LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sonali Energees USA LLC SS-420W-m72H?
Multiplying Sonali Energees USA LLC SS-420W-m72H's 11.27 A short-circuit current by 1.56 equals 17.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Sonali Energees USA LLC SS-420W-m72H pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.61 V cold Voc at 14 F and handles 11.27 A Isc; string inverters cap Sonali Energees USA LLC SS-420W-m72H at 10 panels on 600 V.
Is Sonali Energees USA LLC SS-420W-m72H eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sonali Energees USA LLC SS-420W-m72H rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)