Manufacturer: SOLEX ENERGY LTD Registry: CEC Verified Engineering Specification

SOLEX ENERGY LTD SMFB60HM10-440 is a 440.0 W STC (410.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.28% efficiency, 41.67 V Voc at 25 C, and 45.01 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
410.6 W
Voc @ 25C
41.67 V
Efficiency
20.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLEX ENERGY LTD SMFB60HM10-440 Compare Against Peer CEC Listings?

How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB60HM10-440 handles rooftop heat (410.6 W PTC), 8 kW sizing, and cold winter string voltage.

SOLEX ENERGY LTD builds the SOLEX ENERGY LTD SMFB60HM10-440 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 (440.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Mid-range 41.67 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 20.81 A overcurrent floor served by a 25 A breaker.

Where Does SOLEX ENERGY LTD SMFB60HM10-440 Fall Across Listed CEC Models?

Where SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLEX ENERGY LTD S: 440.0 W

What Dataset Percentiles Define SOLEX ENERGY LTD SMFB60HM10-440?

Percentile placement of SOLEX ENERGY LTD SMFB60HM10-440 across power density (202.8 W/m2), thermal retention, and nameplate STC wattage.

SOLEX ENERGY LTD SMFB60HM10-440 Engineering BenchmarksPercentile comparison of SOLEX ENERGY LTD SMFB60HM10-440 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention93.3%Module Efficiency20.28%

What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB60HM10-440?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB60HM10-440 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,406

20.28% Aperture Efficiency

Power density 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.01 V at -10 C (585.1 V string) and 45.96 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,801 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.67 * (1 + (-0.229/100) * (-10 - 25)) = 45.01 V | OCPD = 1.56 * 13.34 = 20.81 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB60HM10-440: Voc=41.67 V, beta_Voc=-0.229%/C, Isc=13.34 A, STC=440.0 W, Area=2.17 m2.

Result: 13 panels max on 600 V (585.1 V); 19 panels for 8 kW (444 sq ft).

What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB60HM10-440?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB60HM10-440.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMFB60HM10-440.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 410.6 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.67 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.57 V / 12.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.28% (2.17 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many SOLEX ENERGY LTD SMFB60HM10-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 327 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 444 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 537 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB60HM10-440 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMFB60HM10-440 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLEX ENERGY LTD SMFB60HM10-430 430.0 W 401.1 W 41.33 V 34.23 V 19.82%
SOLEX ENERGY LTD SMFB60HM10-435 435.0 W 405.8 W 41.5 V 34.4 V 20.05%
SOLEX ENERGY LTD SMFB60HM10-440 440.0 W 410.6 W 41.67 V 34.57 V 20.28%
SOLEX ENERGY LTD SMFB60HM10-445 445.0 W 415.4 W 41.84 V 34.74 V 20.51%

How Many SOLEX ENERGY LTD SMFB60HM10-440 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLEX ENERGY LTD SMFB60HM10-440 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.67V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.96 V 13 panels 597.5 V 21 panels
-10 C (14 F) 45.01 V 13 panels 585.1 V 22 panels
0 C (32 F) 44.06 V 13 panels 572.8 V 22 panels
25 C (77 F STC) 41.67 V 14 panels 583.4 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB60HM10-440?

Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W), including Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1
Aptos Solar Technology LLC
440.0 W Tie (0 W) 41.18 V 20.56% 94.3%
Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2
Aptos Solar Technology LLC
440.0 W Tie (0 W) 41.18 V 20.56% 94.3%
Elin Energy (Sirius PV) ELNSM60M-HC-440
Elin Energy (Sirius PV)
440.0 W Tie (0 W) 41.12 V 20.47% 94.2%
CertainTeed CTM10440HC11-06
CertainTeed
440.0 W Tie (0 W) 41.02 V 20.37% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB60HM10-440?

Evaluate SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W STC, 41.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB60HM10-440 reaches 45.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (444 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB60HM10-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLEX ENERGY LTD SMFB60HM10-440 8 kW Residential Fit

Needs 19 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 410.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMFB60HM10-440 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SOLEX ENERGY LTD SMFB60HM10-440?

Multiplying SOLEX ENERGY LTD SMFB60HM10-440's 13.34 A short-circuit current by 1.56 equals 20.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SOLEX ENERGY LTD SMFB60HM10-440 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.01 V cold Voc at 14 F and handles 13.34 A Isc; string inverters cap SOLEX ENERGY LTD SMFB60HM10-440 at 13 panels on 600 V.

Is SOLEX ENERGY LTD SMFB60HM10-440 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLEX ENERGY LTD SMFB60HM10-440 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.