Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLEX ENERGY LTD SMFB54HM10-410 — CEC Solar Module Specifications

Manufacturer: SOLEX ENERGY LTD Registry: CEC Verified Engineering Specification

SOLEX ENERGY LTD SMFB54HM10-410 is a 410.0 W STC (383.0 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 38.99 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
383.0 W
Voc @ 25C
38.99 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLEX ENERGY LTD SMFB54HM10-410 Compare Against Peer CEC Listings?

How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB54HM10-410 handles rooftop heat (383.0 W PTC), 8 kW sizing, and cold winter string voltage.

SOLEX ENERGY LTD builds the SOLEX ENERGY LTD SMFB54HM10-410 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 (410.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 38.99 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.06 A overcurrent floor served by a 25 A breaker.

Where Does SOLEX ENERGY LTD SMFB54HM10-410 Fall Across Listed CEC Models?

Where SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLEX ENERGY LTD S: 410.0 W

What Dataset Percentiles Define SOLEX ENERGY LTD SMFB54HM10-410?

Percentile placement of SOLEX ENERGY LTD SMFB54HM10-410 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.

SOLEX ENERGY LTD SMFB54HM10-410 Engineering BenchmarksPercentile comparison of SOLEX ENERGY LTD SMFB54HM10-410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.4%Module Efficiency21.03%

What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB54HM10-410?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB54HM10-410 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.01 V at -20 C (13 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,660 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.99 * (1 + (-0.229/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.5 = 21.06 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB54HM10-410: Voc=38.99 V, beta_Voc=-0.229%/C, Isc=13.5 A, STC=410.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (589.7 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB54HM10-410?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB54HM10-410.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMFB54HM10-410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.0 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.99 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.85 V / 12.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many SOLEX ENERGY LTD SMFB54HM10-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 315 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 420 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 525 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB54HM10-410 architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMFB54HM10-410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLEX ENERGY LTD SMFB54HM10-400 400.0 W 373.4 W 38.57 V 31.47 V 20.51%
SOLEX ENERGY LTD SMFB54HM10-405 405.0 W 378.2 W 38.74 V 31.64 V 20.77%
SOLEX ENERGY LTD SMFB54HM10-410 410.0 W 383.0 W 38.99 V 31.85 V 21.03%
SOLEX ENERGY LTD SMFB54HM10-415 415.0 W 387.8 W 39.16 V 32.02 V 21.28%
SOLEX ENERGY LTD SMFB54HM10-420 420.0 W 392.6 W 39.31 V 32.21 V 21.54%

How Many SOLEX ENERGY LTD SMFB54HM10-410 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLEX ENERGY LTD SMFB54HM10-410 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.99V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.01 V 13 panels 559.1 V 23 panels
-10 C (14 F) 42.12 V 14 panels 589.7 V 23 panels
0 C (32 F) 41.22 V 14 panels 577.1 V 24 panels
25 C (77 F STC) 38.99 V 15 panels 584.9 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB54HM10-410?

Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W), including Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
Auxin Solar AXN10M410B
Auxin Solar
410.0 W Tie (0 W) 37.54 V 21.64% 94.0%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
410.0 W Tie (0 W) 37.51 V 21.58% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB54HM10-410?

Evaluate SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W STC, 38.99 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB54HM10-410 reaches 43.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB54HM10-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLEX ENERGY LTD SMFB54HM10-410 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMFB54HM10-410 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SOLEX ENERGY LTD SMFB54HM10-410?

Multiplying SOLEX ENERGY LTD SMFB54HM10-410's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SOLEX ENERGY LTD SMFB54HM10-410 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap SOLEX ENERGY LTD SMFB54HM10-410 at 14 panels on 600 V.

Is SOLEX ENERGY LTD SMFB54HM10-410 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLEX ENERGY LTD SMFB54HM10-410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.