SOLEX ENERGY LTD SMFB54HM10-410 is a 410.0 W STC (383.0 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 38.99 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 383.0 W
- Voc @ 25C
- 38.99 V
- Efficiency
- 21.03%
How Does SOLEX ENERGY LTD SMFB54HM10-410 Compare Against Peer CEC Listings?
How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB54HM10-410 handles rooftop heat (383.0 W PTC), 8 kW sizing, and cold winter string voltage.
SOLEX ENERGY LTD builds the SOLEX ENERGY LTD SMFB54HM10-410 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 (410.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 38.99 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.06 A overcurrent floor served by a 25 A breaker.
Where Does SOLEX ENERGY LTD SMFB54HM10-410 Fall Across Listed CEC Models?
Where SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SOLEX ENERGY LTD SMFB54HM10-410?
Percentile placement of SOLEX ENERGY LTD SMFB54HM10-410 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB54HM10-410?
Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB54HM10-410 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.01 V at -20 C (13 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,660 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.99 * (1 + (-0.229/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.5 = 21.06 A
Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB54HM10-410: Voc=38.99 V, beta_Voc=-0.229%/C, Isc=13.5 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (589.7 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB54HM10-410?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB54HM10-410.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 383.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.99 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.85 V / 12.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.229 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLEX ENERGY LTD SMFB54HM10-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?
All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB54HM10-410 architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SOLEX ENERGY LTD SMFB54HM10-400 | 400.0 W | 373.4 W | 38.57 V | 31.47 V | 20.51% |
| SOLEX ENERGY LTD SMFB54HM10-405 | 405.0 W | 378.2 W | 38.74 V | 31.64 V | 20.77% |
| SOLEX ENERGY LTD SMFB54HM10-410 | 410.0 W | 383.0 W | 38.99 V | 31.85 V | 21.03% |
| SOLEX ENERGY LTD SMFB54HM10-415 | 415.0 W | 387.8 W | 39.16 V | 32.02 V | 21.28% |
| SOLEX ENERGY LTD SMFB54HM10-420 | 420.0 W | 392.6 W | 39.31 V | 32.21 V | 21.54% |
How Many SOLEX ENERGY LTD SMFB54HM10-410 Modules Fit in a Cold-Weather String?
Maximum series module counts for SOLEX ENERGY LTD SMFB54HM10-410 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.01 V | 13 panels | 559.1 V | 23 panels |
| -10 C (14 F) | 42.12 V | 14 panels | 589.7 V | 23 panels |
| 0 C (32 F) | 41.22 V | 14 panels | 577.1 V | 24 panels |
| 25 C (77 F STC) | 38.99 V | 15 panels | 584.9 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB54HM10-410?
Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W), including Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Auxin Solar AXN10M410B Auxin Solar |
410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |
What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB54HM10-410?
Evaluate SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W STC, 38.99 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB54HM10-410 reaches 43.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB54HM10-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLEX ENERGY LTD SMFB54HM10-410 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLEX ENERGY LTD SMFB54HM10-410 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SOLEX ENERGY LTD SMFB54HM10-410?
Multiplying SOLEX ENERGY LTD SMFB54HM10-410's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can SOLEX ENERGY LTD SMFB54HM10-410 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap SOLEX ENERGY LTD SMFB54HM10-410 at 14 panels on 600 V.
Is SOLEX ENERGY LTD SMFB54HM10-410 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLEX ENERGY LTD SMFB54HM10-410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)