SOLEX ENERGY LTD SMFB54HM10-395 is a 395.0 W STC (368.6 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 38.4 V Voc at 25 C, and 41.48 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 368.6 W
- Voc @ 25C
- 38.4 V
- Efficiency
- 20.26%
How Does SOLEX ENERGY LTD SMFB54HM10-395 Compare Against Peer CEC Listings?
How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB54HM10-395 handles rooftop heat (368.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, SOLEX ENERGY LTD SMFB54HM10-395 exhibits 13.24 A short-circuit current, requiring a 20.65 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Lower 38.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does SOLEX ENERGY LTD SMFB54HM10-395 Fall Across Listed CEC Models?
Where SOLEX ENERGY LTD SMFB54HM10-395 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SOLEX ENERGY LTD SMFB54HM10-395?
Percentile placement of SOLEX ENERGY LTD SMFB54HM10-395 across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB54HM10-395?
Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB54HM10-395 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.48 V at -10 C (580.7 V string) and 42.36 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,741 W PTC; NEC 690.8 OCPD floor is 20.65 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.4 * (1 + (-0.229/100) * (-10 - 25)) = 41.48 V | OCPD = 1.56 * 13.24 = 20.65 A
Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB54HM10-395: Voc=38.4 V, beta_Voc=-0.229%/C, Isc=13.24 A, STC=395.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (580.7 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB54HM10-395?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB54HM10-395.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 368.6 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.3 V / 12.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.229 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLEX ENERGY LTD SMFB54HM10-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB54HM10-395 (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?
All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB54HM10-395 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SOLEX ENERGY LTD SMFB54HM10-390 | 390.0 W | 363.8 W | 38.23 V | 31.13 V | 20.0% |
| SOLEX ENERGY LTD SMFB54HM10-395 | 395.0 W | 368.6 W | 38.4 V | 31.3 V | 20.26% |
How Many SOLEX ENERGY LTD SMFB54HM10-395 Modules Fit in a Cold-Weather String?
Maximum series module counts for SOLEX ENERGY LTD SMFB54HM10-395 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.36 V | 14 panels | 593.0 V | 23 panels |
| -10 C (14 F) | 41.48 V | 14 panels | 580.7 V | 24 panels |
| 0 C (32 F) | 40.6 V | 14 panels | 568.4 V | 24 panels |
| 25 C (77 F STC) | 38.4 V | 15 panels | 576.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB54HM10-395?
Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB54HM10-395 (395.0 W), including Auxin Solar AXN10M395B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M395B Auxin Solar |
395.0 W | Tie (0 W) | 37.03 V | 20.84% | 93.9% |
| Convalt Manufacturing LLC CVLT395-108M-BB Convalt Manufacturing LLC |
395.0 W | Tie (0 W) | 37.03 V | 20.36% | 91.9% |
| Elin Energy (Sirius PV) ELNSM54M-HC-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.2% |
What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB54HM10-395?
Evaluate SOLEX ENERGY LTD SMFB54HM10-395 (395.0 W STC, 38.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB54HM10-395 reaches 42.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB54HM10-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLEX ENERGY LTD SMFB54HM10-395 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M395B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLEX ENERGY LTD SMFB54HM10-395 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.
Why is SOLEX ENERGY LTD SMFB54HM10-395 PTC wattage (368.6 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 368.6 W PTC (93.3% retention) across SOLEX ENERGY LTD SMFB54HM10-395's 1.95 m2 aperture.
Who should skip SOLEX ENERGY LTD SMFB54HM10-395 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 SOLEX ENERGY LTD SMFB54HM10-395 panels (441 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M395B.
What is the 1,000 V commercial string limit for SOLEX ENERGY LTD SMFB54HM10-395?
On 1,000 V commercial inverters at -10 C (41.48 V cold Voc), SOLEX ENERGY LTD SMFB54HM10-395 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SOLEX ENERGY LTD SMFB54HM10-395.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)