SOLEX ENERGY LTD SMB54HM10-410 is a 410.0 W STC (382.1 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 38.99 V Voc at 25 C, and 42.1 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 382.1 W
- Voc @ 25C
- 38.99 V
- Efficiency
- 21.03%
How Does SOLEX ENERGY LTD SMB54HM10-410 Compare Against Peer CEC Listings?
Solar engineering breakdown for SOLEX ENERGY LTD SMB54HM10-410: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 410.0 W STC and 382.1 W PTC, SOLEX ENERGY LTD SMB54HM10-410 sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Lower 38.99 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 rates 410.0 W.
Where Does SOLEX ENERGY LTD SMB54HM10-410 Fall Across Listed CEC Models?
Distribution marker showing SOLEX ENERGY LTD SMB54HM10-410 (410.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define SOLEX ENERGY LTD SMB54HM10-410?
Dataset percentiles tracking SOLEX ENERGY LTD SMB54HM10-410 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMB54HM10-410?
Benchmark highlights for SOLEX ENERGY LTD SMB54HM10-410 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.1 V at -10 C (589.4 V string) and 42.99 V at -20 C (13 max).
20 Panels = 8,200 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,642 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.99 * (1 + (-0.228/100) * (-10 - 25)) = 42.1 V | OCPD = 1.56 * 13.5 = 21.06 A
Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMB54HM10-410: Voc=38.99 V, beta_Voc=-0.228%/C, Isc=13.5 A, STC=410.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (589.4 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for SOLEX ENERGY LTD SMB54HM10-410?
Official CEC datasheet figures for SOLEX ENERGY LTD SMB54HM10-410 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 382.1 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.99 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.85 V / 12.88 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.228 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLEX ENERGY LTD SMB54HM10-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many SOLEX ENERGY LTD SMB54HM10-410 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?
Consolidated SOLEX ENERGY LTD wattage variants sharing the SOLEX ENERGY LTD SMB54HM10-410 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SOLEX ENERGY LTD SMB54HM10-400 | 400.0 W | 372.5 W | 38.57 V | 31.47 V | 20.51% |
| SOLEX ENERGY LTD SMB54HM10-405 | 405.0 W | 377.3 W | 38.74 V | 31.64 V | 20.77% |
| SOLEX ENERGY LTD SMB54HM10-410 | 410.0 W | 382.1 W | 38.99 V | 31.85 V | 21.03% |
| SOLEX ENERGY LTD SMB54HM10-415 | 415.0 W | 386.9 W | 39.16 V | 32.02 V | 21.28% |
| SOLEX ENERGY LTD SMB54HM10-420 | 420.0 W | 391.7 W | 39.31 V | 32.21 V | 21.54% |
How Many SOLEX ENERGY LTD SMB54HM10-410 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on SOLEX ENERGY LTD SMB54HM10-410 (42.1 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.99 V | 13 panels | 558.9 V | 23 panels |
| -10 C (14 F) | 42.1 V | 14 panels | 589.4 V | 23 panels |
| 0 C (32 F) | 41.21 V | 14 panels | 576.9 V | 24 panels |
| 25 C (77 F STC) | 38.99 V | 15 panels | 584.9 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMB54HM10-410?
Competing CEC solar panels closest to SOLEX ENERGY LTD SMB54HM10-410 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2 Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| Auxin Solar AXN10M410B Auxin Solar |
410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |
What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMB54HM10-410?
Evaluate SOLEX ENERGY LTD SMB54HM10-410 (410.0 W STC, 38.99 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMB54HM10-410 reaches 42.99 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMB54HM10-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLEX ENERGY LTD SMB54HM10-410 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 382.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLEX ENERGY LTD SMB54HM10-410 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.
How many SOLEX ENERGY LTD SMB54HM10-410 panels fit on a 600 V winter solar string?
At -10 C (14 F), SOLEX ENERGY LTD SMB54HM10-410 cold Voc rises from 38.99 V to 42.1 V (beta_Voc -0.228%/C), capping a 600 V string at 14 panels (589.4 V).
How much roof area does an 8 kW array of SOLEX ENERGY LTD SMB54HM10-410 need?
An 8 kW DC system uses 20 SOLEX ENERGY LTD SMB54HM10-410 modules (8,200 W STC / 7,642 W PTC), covering roughly 420 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does SOLEX ENERGY LTD SMB54HM10-410 compare against Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1?
SOLEX ENERGY LTD SMB54HM10-410 outputs 410.0 W STC (38.99 V Voc, rank #8,539 of 21,677), while Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)