Solartech Energy ASC-6P-72-270 is a 270.0 W STC (238.6 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.89% efficiency, 43.85 V Voc at 25 C, and 49.38 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 238.6 W
- Voc @ 25C
- 43.85 V
- Efficiency
- 13.89%
How Does Solartech Energy ASC-6P-72-270 Compare Against Peer CEC Listings?
Solar engineering breakdown for Solartech Energy ASC-6P-72-270: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Across 1,407 Multi-c-Si listings from Solartech Energy and peers, Solartech Energy ASC-6P-72-270 stands 8.8 W below the 278.8 W Multi-c-Si median and typical 88.4% PTC-to-STC thermal output (238.6 W real-world rating). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,554-$2,568/yr in baseline US bill offset. Mid-range 43.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Solartech Energy ASC-6P-72-270 Fall Across Listed CEC Models?
Distribution marker showing Solartech Energy ASC-6P-72-270 (270.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Solartech Energy ASC-6P-72-270?
Dataset percentiles tracking Solartech Energy ASC-6P-72-270 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Solartech Energy ASC-6P-72-270?
Benchmark highlights for Solartech Energy ASC-6P-72-270 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.89% Aperture Efficiency
Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.38 V at -10 C (592.6 V string) and 50.95 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.3 m2 (628 sq ft) producing 7,158 W PTC; NEC 690.8 OCPD floor is 12.62 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.85 * (1 + (-0.36/100) * (-10 - 25)) = 49.38 V | OCPD = 1.56 * 8.09 = 12.62 A
Inputs from CEC Modules.csv for Solartech Energy ASC-6P-72-270: Voc=43.85 V, beta_Voc=-0.36%/C, Isc=8.09 A, STC=270.0 W, Area=1.944 m2.
Result: 12 panels max on 600 V (592.6 V); 30 panels for 8 kW (628 sq ft).
What Are the Published CEC Specifications for Solartech Energy ASC-6P-72-270?
Official CEC datasheet figures for Solartech Energy ASC-6P-72-270 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 238.6 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.85 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.55 V / 7.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.89% (1.944 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Solartech Energy ASC-6P-72-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solartech Energy ASC-6P-72-270 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 481 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 628 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 795 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?
Consolidated Solartech Energy wattage variants sharing the Solartech Energy ASC-6P-72-270 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Solartech Energy ASC-6P-72-265 | 265.0 W | 234.1 W | 43.5 V | 35.48 V | 13.63% |
| Solartech Energy ASC-6P-72-270 | 270.0 W | 238.6 W | 43.85 V | 35.55 V | 13.89% |
How Many Solartech Energy ASC-6P-72-270 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6P-72-270 (49.38 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.95 V | 11 panels | 560.5 V | 19 panels |
| -10 C (14 F) | 49.38 V | 12 panels | 592.6 V | 20 panels |
| 0 C (32 F) | 47.8 V | 12 panels | 573.6 V | 20 panels |
| 25 C (77 F STC) | 43.85 V | 13 panels | 570.1 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-72-270?
Competing CEC solar panels closest to Solartech Energy ASC-6P-72-270 in nameplate wattage and Voc, starting with Centrosolar America DP72 270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| Anhui Rinengzhongtian Semiconductor Development QJM270-72 Anhui Rinengzhongtian Semiconductor Development |
270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-72-270?
Evaluate Solartech Energy ASC-6P-72-270 (270.0 W STC, 43.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-72-270 reaches 50.95 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-72-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solartech Energy ASC-6P-72-270 8 kW Residential Fit
Needs 30 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solartech Energy ASC-6P-72-270 by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solartech Energy ASC-6P-72-270?
Multiplying Solartech Energy ASC-6P-72-270's 8.09 A short-circuit current by 1.56 equals 12.62 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Solartech Energy ASC-6P-72-270 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.38 V cold Voc at 14 F and handles 8.09 A Isc; string inverters cap Solartech Energy ASC-6P-72-270 at 12 panels on 600 V.
Is Solartech Energy ASC-6P-72-270 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solartech Energy ASC-6P-72-270 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)