Solartech Energy ASC-6P-60A-265-3BB — CEC Solar Module Specifications

Manufacturer: Solartech Energy Registry: CEC Verified Engineering Specification

Solartech Energy ASC-6P-60A-265-3BB is a 265.0 W STC (239.1 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.16% efficiency, 38.4 V Voc at 25 C, and 42.96 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
239.1 W
Voc @ 25C
38.4 V
Efficiency
16.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Energy ASC-6P-60A-265-3BB Compare Against Peer CEC Listings?

How Solartech Energy Solartech Energy ASC-6P-60A-265-3BB handles rooftop heat (239.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solartech Energy ASC-6P-60A-265-3BB exhibits 8.73 A short-circuit current, requiring a 13.62 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (13.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.8 m2 for an 8 kW system (38 panels for 10 kW). Lower 38.4 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does Solartech Energy ASC-6P-60A-265-3BB Fall Across Listed CEC Models?

Where Solartech Energy ASC-6P-60A-265-3BB (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Energy ASC-6P-60A-265-3BB (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Energy A: 265.0 W

What Dataset Percentiles Define Solartech Energy ASC-6P-60A-265-3BB?

Percentile placement of Solartech Energy ASC-6P-60A-265-3BB across power density (161.6 W/m2), thermal retention, and nameplate STC wattage.

Solartech Energy ASC-6P-60A-265-3BB Engineering BenchmarksPercentile comparison of Solartech Energy ASC-6P-60A-265-3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention90.2%Module Efficiency16.16%

What Do the Dataset Ranks Show for Solartech Energy ASC-6P-60A-265-3BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solartech Energy ASC-6P-60A-265-3BB specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,903

16.16% Aperture Efficiency

Power density 161.6 W/m2 (3.75 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.96 V at -10 C (558.5 V string) and 44.26 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.8 m2 (547 sq ft) producing 7,412 W PTC; NEC 690.8 OCPD floor is 13.62 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.4 * (1 + (-0.339/100) * (-10 - 25)) = 42.96 V | OCPD = 1.56 * 8.73 = 13.62 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6P-60A-265-3BB: Voc=38.4 V, beta_Voc=-0.339%/C, Isc=8.73 A, STC=265.0 W, Area=1.64 m2.

Result: 13 panels max on 600 V (558.5 V); 31 panels for 8 kW (547 sq ft).

What Are the Published CEC Specifications for Solartech Energy ASC-6P-60A-265-3BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solartech Energy ASC-6P-60A-265-3BB.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6P-60A-265-3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 239.1 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.2 V / 8.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.16% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Solartech Energy ASC-6P-60A-265-3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solartech Energy ASC-6P-60A-265-3BB (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 406 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 547 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 671 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?

All closely matched Solartech Energy wattages and cosmetic trims sharing the Solartech Energy ASC-6P-60A-265-3BB architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Solartech Energy ASC-6P-60A-265-3BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solartech Energy ASC-6P-60A-255-3BB 255.0 W 229.8 W 38.2 V 31.25 V 15.55%
Solartech Energy ASC-6P-60A-260-3BB 260.0 W 234.4 W 38.28 V 31.71 V 15.86%
Solartech Energy ASC-6P-60A-265-3BB 265.0 W 239.1 W 38.4 V 32.2 V 16.16%
Solartech Energy ASC-6P-60A-270-3BB 270.0 W 243.7 W 38.6 V 32.46 V 16.47%

How Many Solartech Energy ASC-6P-60A-265-3BB Modules Fit in a Cold-Weather String?

Maximum series module counts for Solartech Energy ASC-6P-60A-265-3BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.4V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.26 V 13 panels 575.4 V 22 panels
-10 C (14 F) 42.96 V 13 panels 558.5 V 23 panels
0 C (32 F) 41.65 V 14 panels 583.1 V 24 panels
25 C (77 F STC) 38.4 V 15 panels 576.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-60A-265-3BB?

Alternative CEC solar modules from competing brands near Solartech Energy ASC-6P-60A-265-3BB (265.0 W), including Centrosolar America CP60 265-C1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America CP60 265-C1
Centrosolar America
265.0 W Tie (0 W) 38.3 V 16.29% 90.4%
GermanSolar USA GSM6-60-265W
GermanSolar USA
265.0 W Tie (0 W) 38.3 V 16.29% 90.5%
Centrosolar America EM60 265BB
Centrosolar America
265.0 W Tie (0 W) 38.29 V 16.45% 91.0%
Centrosolar America EP60 265BW
Centrosolar America
265.0 W Tie (0 W) 38.29 V 16.45% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-60A-265-3BB?

Evaluate Solartech Energy ASC-6P-60A-265-3BB (265.0 W STC, 38.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-60A-265-3BB reaches 44.26 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-60A-265-3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Energy ASC-6P-60A-265-3BB 8 kW Residential Fit

Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America CP60 265-C1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 239.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6P-60A-265-3BB by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solartech Energy ASC-6P-60A-265-3BB PTC wattage (239.1 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 239.1 W PTC (90.2% retention) across Solartech Energy ASC-6P-60A-265-3BB's 1.64 m2 aperture.

Who should skip Solartech Energy ASC-6P-60A-265-3BB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Solartech Energy ASC-6P-60A-265-3BB panels (547 sq ft) leave unusable roof gaps vs. Centrosolar America CP60 265-C1.

What is the 1,000 V commercial string limit for Solartech Energy ASC-6P-60A-265-3BB?

On 1,000 V commercial inverters at -10 C (42.96 V cold Voc), Solartech Energy ASC-6P-60A-265-3BB fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solartech Energy ASC-6P-60A-265-3BB.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.