Solartech Energy ASC-6P-48-200 is a 200.0 W STC (177.2 W PTC) Multi-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 15.09% efficiency, 30.12 V Voc at 25 C, and 33.92 V cold Voc at -10 C (17 panels max per 600 V string).
- STC Wattage
- 200.0 W
- PTC Wattage
- 177.2 W
- Voc @ 25C
- 30.12 V
- Efficiency
- 15.09%
How Does Solartech Energy ASC-6P-48-200 Compare Against Peer CEC Listings?
Solar engineering breakdown for Solartech Energy ASC-6P-48-200: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Measured at 200.0 W STC and 177.2 W PTC, Solartech Energy ASC-6P-48-200 sits -185.0 W vs all-CEC median (below all-CEC median; higher than 2.7% of peers) among 21,677 listed modules. Power density reaches 150.9 W/m2 (4.82 percentage points below 19.91% CEC median). Lower 30.12 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 29 panels in series. Alternative peer Centrosolar America DP48 200 rates 200.0 W.
Where Does Solartech Energy ASC-6P-48-200 Fall Across Listed CEC Models?
Distribution marker showing Solartech Energy ASC-6P-48-200 (200.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Solartech Energy ASC-6P-48-200?
Dataset percentiles tracking Solartech Energy ASC-6P-48-200 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Solartech Energy ASC-6P-48-200?
Benchmark highlights for Solartech Energy ASC-6P-48-200 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
200.0 W STC · Higher Than 2.7%
200.0 W STC (-185.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.09% Aperture Efficiency
Power density 150.9 W/m2 (4.82 percentage points below 19.91% CEC median). PTC/STC ratio: 88.6% (rank #21,091).
17 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.92 V at -10 C (576.6 V string) and 35.0 V at -20 C (17 max).
40 Panels = 8,000 W STC
Occupies 53.0 m2 (570 sq ft) producing 7,088 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 30.12 * (1 + (-0.36/100) * (-10 - 25)) = 33.92 V | OCPD = 1.56 * 8.63 = 13.46 A
Inputs from CEC Modules.csv for Solartech Energy ASC-6P-48-200: Voc=30.12 V, beta_Voc=-0.36%/C, Isc=8.63 A, STC=200.0 W, Area=1.325 m2.
Result: 17 panels max on 600 V (576.6 V); 40 panels for 8 kW (570 sq ft).
What Are the Published CEC Specifications for Solartech Energy ASC-6P-48-200?
Official CEC datasheet figures for Solartech Energy ASC-6P-48-200 (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 200.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 177.2 W (88.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 30.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 24.6 V / 8.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.09% (1.325 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many Solartech Energy ASC-6P-48-200 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solartech Energy ASC-6P-48-200 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 30 | 6.0 kW | 428 sq ft | $1,502 | $2,539 |
| 8 kW Class | 40 | 8.0 kW | 570 sq ft | $2,002 | $3,386 |
| 10 kW Class | 50 | 10.0 kW | 713 sq ft | $2,503 | $4,232 |
How Many Solartech Energy ASC-6P-48-200 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6P-48-200 (33.92 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 35.0 V | 17 panels | 595.0 V | 28 panels |
| -10 C (14 F) | 33.92 V | 17 panels | 576.6 V | 29 panels |
| 0 C (32 F) | 32.83 V | 18 panels | 590.9 V | 30 panels |
| 25 C (77 F STC) | 30.12 V | 19 panels | 572.3 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-48-200?
Competing CEC solar panels closest to Solartech Energy ASC-6P-48-200 in nameplate wattage and Voc, starting with Centrosolar America DP48 200.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP48 200 Centrosolar America |
200.0 W | Tie (0 W) | 30.12 V | 15.09% | 88.6% |
| Gintung Energy ASEC-210G6M68 Gintung Energy |
210.0 W | +10.0 W | 30.14 V | 16.1% | 88.1% |
| Gintung Energy ASEC-210G6S68 Gintung Energy |
210.0 W | +10.0 W | 30.14 V | 16.1% | 87.8% |
| Gintung Energy GTEC-210G6M68 Gintung Energy |
210.0 W | +10.0 W | 30.14 V | 16.1% | 88.1% |
What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-48-200?
Evaluate Solartech Energy ASC-6P-48-200 (200.0 W STC, 30.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-48-200 reaches 35.0 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 40 panels for an 8 kW build require 570 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (570 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-48-200 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solartech Energy ASC-6P-48-200 8 kW Residential Fit
Needs 40 modules (570 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Centrosolar America DP48 200.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 177.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solartech Energy ASC-6P-48-200 by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Solartech Energy ASC-6P-48-200 panels fit on a 600 V winter solar string?
At -10 C (14 F), Solartech Energy ASC-6P-48-200 cold Voc rises from 30.12 V to 33.92 V (beta_Voc -0.36%/C), capping a 600 V string at 17 panels (576.6 V).
How much roof area does an 8 kW array of Solartech Energy ASC-6P-48-200 need?
An 8 kW DC system uses 40 Solartech Energy ASC-6P-48-200 modules (8,000 W STC / 7,088 W PTC), covering roughly 570 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does Solartech Energy ASC-6P-48-200 compare against Centrosolar America DP48 200?
Solartech Energy ASC-6P-48-200 outputs 200.0 W STC (30.12 V Voc, rank #21,027 of 21,677), while Centrosolar America DP48 200 delivers 200.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)