Solartech Energy ASC-6M-72C-320-3BB — CEC Solar Module Specifications

Manufacturer: Solartech Energy Registry: CEC Verified Engineering Specification

Solartech Energy ASC-6M-72C-320-3BB is a 320.0 W STC (290.8 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.46% efficiency, 46.3 V Voc at 25 C, and 51.55 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
290.8 W
Voc @ 25C
46.3 V
Efficiency
16.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Energy ASC-6M-72C-320-3BB Compare Against Peer CEC Listings?

Solar engineering breakdown for Solartech Energy ASC-6M-72C-320-3BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Across 5,889 Mono-c-Si listings from Solartech Energy and peers, Solartech Energy ASC-6M-72C-320-3BB stands 90.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (290.8 W real-world rating). Sizing 6 kW (19 panels) to 10 kW (32 panels) yields $1,522-$2,563/yr in baseline US bill offset. Mid-range 46.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Solartech Energy ASC-6M-72C-320-3BB Fall Across Listed CEC Models?

Distribution marker showing Solartech Energy ASC-6M-72C-320-3BB (320.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Energy ASC-6M-72C-320-3BB (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Energy A: 320.0 W

What Dataset Percentiles Define Solartech Energy ASC-6M-72C-320-3BB?

Dataset percentiles tracking Solartech Energy ASC-6M-72C-320-3BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Solartech Energy ASC-6M-72C-320-3BB Engineering BenchmarksPercentile comparison of Solartech Energy ASC-6M-72C-320-3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention90.9%Module Efficiency16.46%

What Do the Dataset Ranks Show for Solartech Energy ASC-6M-72C-320-3BB?

Benchmark highlights for Solartech Energy ASC-6M-72C-320-3BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,449

16.46% Aperture Efficiency

Power density 164.6 W/m2 (3.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.55 V at -10 C (567.0 V string) and 53.05 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.3 * (1 + (-0.324/100) * (-10 - 25)) = 51.55 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6M-72C-320-3BB: Voc=46.3 V, beta_Voc=-0.324%/C, Isc=8.9 A, STC=320.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (567.0 V); 25 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for Solartech Energy ASC-6M-72C-320-3BB?

Official CEC datasheet figures for Solartech Energy ASC-6M-72C-320-3BB (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6M-72C-320-3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 290.8 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.6 V / 8.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.46% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Solartech Energy ASC-6M-72C-320-3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solartech Energy ASC-6M-72C-320-3BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 398 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 523 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 670 sq ft $2,563 $4,334

How Many Solartech Energy ASC-6M-72C-320-3BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solartech Energy ASC-6M-72C-320-3BB (51.55 V at 14 F).

Computed from Voc=46.3V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.05 V 11 panels 583.5 V 18 panels
-10 C (14 F) 51.55 V 11 panels 567.0 V 19 panels
0 C (32 F) 50.05 V 11 panels 550.5 V 19 panels
25 C (77 F STC) 46.3 V 12 panels 555.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6M-72C-320-3BB?

Competing CEC solar panels closest to Solartech Energy ASC-6M-72C-320-3BB in nameplate wattage and Voc, starting with Centrosolar America EM72 320BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EM72 320BW
Centrosolar America
320.0 W Tie (0 W) 46.31 V 16.64% 91.3%
Centrosolar America EM72 320SW
Centrosolar America
320.0 W Tie (0 W) 46.31 V 16.64% 91.3%
Bluesun Solar Energy Tech CoLtd BSM320P-72
Bluesun Solar Energy Tech CoLtd
320.0 W Tie (0 W) 46.19 V 16.51% 91.3%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
320.0 W Tie (0 W) 45.94 V 16.64% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6M-72C-320-3BB?

Evaluate Solartech Energy ASC-6M-72C-320-3BB (320.0 W STC, 46.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6M-72C-320-3BB reaches 53.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6M-72C-320-3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Energy ASC-6M-72C-320-3BB 8 kW Residential Fit

Needs 25 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EM72 320BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 290.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6M-72C-320-3BB by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solartech Energy ASC-6M-72C-320-3BB?

Multiplying Solartech Energy ASC-6M-72C-320-3BB's 8.9 A short-circuit current by 1.56 equals 13.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Solartech Energy ASC-6M-72C-320-3BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.55 V cold Voc at 14 F and handles 8.9 A Isc; string inverters cap Solartech Energy ASC-6M-72C-320-3BB at 11 panels on 600 V.

Is Solartech Energy ASC-6M-72C-320-3BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solartech Energy ASC-6M-72C-320-3BB rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.