Solartech Energy ASC-6M-72B-320-3BB is a 320.0 W STC (290.8 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.46% efficiency, 46.3 V Voc at 25 C, and 51.55 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 290.8 W
- Voc @ 25C
- 46.3 V
- Efficiency
- 16.46%
How Does Solartech Energy ASC-6M-72B-320-3BB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solartech Energy ASC-6M-72B-320-3BB (Mono-c-Si) residential solar systems.
Solartech Energy ASC-6M-72B-320-3BB delivers 164.6 W/m2 (3.45 percentage points below 19.91% CEC median) and typical 90.9% PTC-to-STC thermal output (290.8 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft). At -4 F (-20 C), string voltage climbs to 53.05 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Centrosolar America EM72 320BW (320.0 W).
Where Does Solartech Energy ASC-6M-72B-320-3BB Fall Across Listed CEC Models?
Comparison of Solartech Energy ASC-6M-72B-320-3BB (320.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define Solartech Energy ASC-6M-72B-320-3BB?
Relative ranking of Solartech Energy ASC-6M-72B-320-3BB across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for Solartech Energy ASC-6M-72B-320-3BB?
Summary of Solartech Energy ASC-6M-72B-320-3BB output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.46% Aperture Efficiency
Power density 164.6 W/m2 (3.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.55 V at -10 C (567.0 V string) and 53.05 V at -20 C (11 max).
25 Panels = 8,000 W STC
Occupies 48.6 m2 (523 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.3 * (1 + (-0.324/100) * (-10 - 25)) = 51.55 V | OCPD = 1.56 * 8.9 = 13.88 A
Inputs from CEC Modules.csv for Solartech Energy ASC-6M-72B-320-3BB: Voc=46.3 V, beta_Voc=-0.324%/C, Isc=8.9 A, STC=320.0 W, Area=1.944 m2.
Result: 11 panels max on 600 V (567.0 V); 25 panels for 8 kW (523 sq ft).
What Are the Published CEC Specifications for Solartech Energy ASC-6M-72B-320-3BB?
Complete CEC test sheet for Solartech Energy ASC-6M-72B-320-3BB including Isc (8.9 A), Voc (46.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 290.8 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.6 V / 8.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.46% (1.944 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solartech Energy ASC-6M-72B-320-3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solartech Energy ASC-6M-72B-320-3BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 398 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 523 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 670 sq ft | $2,563 | $4,334 |
How Many Solartech Energy ASC-6M-72B-320-3BB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Solartech Energy ASC-6M-72B-320-3BB (46.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.05 V | 11 panels | 583.5 V | 18 panels |
| -10 C (14 F) | 51.55 V | 11 panels | 567.0 V | 19 panels |
| 0 C (32 F) | 50.05 V | 11 panels | 550.5 V | 19 panels |
| 25 C (77 F STC) | 46.3 V | 12 panels | 555.6 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6M-72B-320-3BB?
Four comparable CEC modules such as Centrosolar America EM72 320BW (320.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America EM72 320BW Centrosolar America |
320.0 W | Tie (0 W) | 46.31 V | 16.64% | 91.3% |
| Centrosolar America EM72 320SW Centrosolar America |
320.0 W | Tie (0 W) | 46.31 V | 16.64% | 91.3% |
| Bluesun Solar Energy Tech CoLtd BSM320P-72 Bluesun Solar Energy Tech CoLtd |
320.0 W | Tie (0 W) | 46.19 V | 16.51% | 91.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
320.0 W | Tie (0 W) | 45.94 V | 16.64% | 91.2% |
What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6M-72B-320-3BB?
Evaluate Solartech Energy ASC-6M-72B-320-3BB (320.0 W STC, 46.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6M-72B-320-3BB reaches 53.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft).
- 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6M-72B-320-3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solartech Energy ASC-6M-72B-320-3BB 8 kW Residential Fit
Needs 25 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EM72 320BW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 290.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solartech Energy ASC-6M-72B-320-3BB by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Solartech Energy ASC-6M-72B-320-3BB panels fit on a 600 V winter solar string?
At -10 C (14 F), Solartech Energy ASC-6M-72B-320-3BB cold Voc rises from 46.3 V to 51.55 V (beta_Voc -0.324%/C), capping a 600 V string at 11 panels (567.0 V).
How much roof area does an 8 kW array of Solartech Energy ASC-6M-72B-320-3BB need?
An 8 kW DC system uses 25 Solartech Energy ASC-6M-72B-320-3BB modules (8,000 W STC / 7,270 W PTC), covering roughly 523 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does Solartech Energy ASC-6M-72B-320-3BB compare against Centrosolar America EM72 320BW?
Solartech Energy ASC-6M-72B-320-3BB outputs 320.0 W STC (46.3 V Voc, rank #14,944 of 21,677), while Centrosolar America EM72 320BW delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)