Skip to main content
WireAndSun
Calculators
CEC PV Module

Solartech Energy ASC-6M-60-260-3BB — CEC Solar Module Specifications

Manufacturer: Solartech Energy Registry: CEC Verified Engineering Specification

Solartech Energy ASC-6M-60-260-3BB is a 260.0 W STC (236.0 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.86% efficiency, 38.2 V Voc at 25 C, and 42.53 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
236.0 W
Voc @ 25C
38.2 V
Efficiency
15.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Energy ASC-6M-60-260-3BB Compare Against Peer CEC Listings?

Engineering position of Solartech Energy ASC-6M-60-260-3BB (260.0 W STC) vs. Centrosolar America DM60 260 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Solartech Energy ASC-6M-60-260-3BB pairs typical 90.8% PTC-to-STC thermal output (236.0 W real-world rating) with 38.2 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,316 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM60 260 offers a 260.0 W alternative.

Where Does Solartech Energy ASC-6M-60-260-3BB Fall Across Listed CEC Models?

Plots Solartech Energy ASC-6M-60-260-3BB at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Energy ASC-6M-60-260-3BB (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Energy A: 260.0 W

What Dataset Percentiles Define Solartech Energy ASC-6M-60-260-3BB?

Benchmarks Solartech Energy ASC-6M-60-260-3BB on STC wattage, thermal PTC/STC retention, and 15.86 aperture conversion efficiency against CEC peers.

Solartech Energy ASC-6M-60-260-3BB Engineering BenchmarksPercentile comparison of Solartech Energy ASC-6M-60-260-3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention90.8%Module Efficiency15.86%

What Do the Dataset Ranks Show for Solartech Energy ASC-6M-60-260-3BB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solartech Energy ASC-6M-60-260-3BB by Solartech Energy.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,383

15.86% Aperture Efficiency

Power density 158.5 W/m2 (4.05 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.53 V at -10 C (595.4 V string) and 43.77 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.8 m2 (547 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.2 * (1 + (-0.324/100) * (-10 - 25)) = 42.53 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6M-60-260-3BB: Voc=38.2 V, beta_Voc=-0.324%/C, Isc=8.8 A, STC=260.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (595.4 V); 31 panels for 8 kW (547 sq ft).

What Are the Published CEC Specifications for Solartech Energy ASC-6M-60-260-3BB?

Laboratory test ratings recorded for Solartech Energy ASC-6M-60-260-3BB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6M-60-260-3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.0 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.4 V / 8.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.86% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Solartech Energy ASC-6M-60-260-3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (547 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solartech Energy ASC-6M-60-260-3BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 424 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 547 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 688 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?

Sibling wattage bins and frame colors grouped with Solartech Energy ASC-6M-60-260-3BB under Solartech Energy to prevent duplicate spec pages.

Sibling CEC listings grouped into the Solartech Energy ASC-6M-60-260-3BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solartech Energy ASC-6M-60-250-3BB 250.0 W 226.7 W 37.4 V 30.6 V 15.25%
Solartech Energy ASC-6M-60-255-3BB 255.0 W 231.4 W 37.9 V 31.1 V 15.55%
Solartech Energy ASC-6M-60-260-3BB 260.0 W 236.0 W 38.2 V 31.4 V 15.86%
Solartech Energy ASC-6M-60-265-3BB 265.0 W 240.7 W 38.5 V 32.0 V 16.16%
Solartech Energy ASC-6M-60-270-3BB 270.0 W 245.3 W 38.8 V 32.2 V 16.47%

How Many Solartech Energy ASC-6M-60-260-3BB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Solartech Energy ASC-6M-60-260-3BB (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.2V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.77 V 13 panels 569.0 V 22 panels
-10 C (14 F) 42.53 V 14 panels 595.4 V 23 panels
0 C (32 F) 41.29 V 14 panels 578.1 V 24 panels
25 C (77 F STC) 38.2 V 15 panels 573.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6M-60-260-3BB?

Closest cross-brand CEC competitors to Solartech Energy ASC-6M-60-260-3BB matched near 260.0 W STC and 38.2 V Voc, led by Centrosolar America DM60 260.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM60 260
Centrosolar America
260.0 W Tie (0 W) 38.2 V 15.86% 90.8%
Centrosolar America DP60 260
Centrosolar America
260.0 W Tie (0 W) 38.28 V 15.86% 90.2%
BYD Company Limited BYD 260P6C-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.98% 90.4%
BYD Company Limited BYD260P6K-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.95% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6M-60-260-3BB?

Evaluate Solartech Energy ASC-6M-60-260-3BB (260.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6M-60-260-3BB reaches 43.77 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6M-60-260-3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Energy ASC-6M-60-260-3BB 8 kW Residential Fit

Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 260.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6M-60-260-3BB by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solartech Energy ASC-6M-60-260-3BB?

Multiplying Solartech Energy ASC-6M-60-260-3BB's 8.8 A short-circuit current by 1.56 equals 13.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Solartech Energy ASC-6M-60-260-3BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.53 V cold Voc at 14 F and handles 8.8 A Isc; string inverters cap Solartech Energy ASC-6M-60-260-3BB at 14 panels on 600 V.

Is Solartech Energy ASC-6M-60-260-3BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solartech Energy ASC-6M-60-260-3BB rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.