Manufacturer: Sinotec USA LLC Registry: CEC Verified Engineering Specification

Sinotec USA LLC STS-390P-54DD is a 390.0 W STC (365.9 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.1% efficiency, 36.8 V Voc at 25 C, and 39.97 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
365.9 W
Voc @ 25C
36.8 V
Efficiency
20.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sinotec USA LLC STS-390P-54DD Compare Against Peer CEC Listings?

How Sinotec USA LLC Sinotec USA LLC STS-390P-54DD handles rooftop heat (365.9 W PTC), 8 kW sizing, and cold winter string voltage.

Sinotec USA LLC builds the Sinotec USA LLC STS-390P-54DD (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M754BH-390BB (390.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Lower 36.8 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 20.81 A overcurrent floor served by a 25 A breaker.

Where Does Sinotec USA LLC STS-390P-54DD Fall Across Listed CEC Models?

Where Sinotec USA LLC STS-390P-54DD (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sinotec USA LLC STS-390P-54DD (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSinotec USA LLC ST: 390.0 W

What Dataset Percentiles Define Sinotec USA LLC STS-390P-54DD?

Percentile placement of Sinotec USA LLC STS-390P-54DD across power density (201.0 W/m2), thermal retention, and nameplate STC wattage.

Sinotec USA LLC STS-390P-54DD Engineering BenchmarksPercentile comparison of Sinotec USA LLC STS-390P-54DD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.8%Module Efficiency20.1%

What Do the Dataset Ranks Show for Sinotec USA LLC STS-390P-54DD?

Four critical engineering numbers homeowners and solar installers check first when reviewing Sinotec USA LLC STS-390P-54DD specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,120

20.1% Aperture Efficiency

Power density 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.97 V at -10 C (599.5 V string) and 40.87 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.8 * (1 + (-0.246/100) * (-10 - 25)) = 39.97 V | OCPD = 1.56 * 13.34 = 20.81 A

Inputs from CEC Modules.csv for Sinotec USA LLC STS-390P-54DD: Voc=36.8 V, beta_Voc=-0.246%/C, Isc=13.34 A, STC=390.0 W, Area=1.94 m2.

Result: 15 panels max on 600 V (599.5 V); 21 panels for 8 kW (439 sq ft).

What Are the Published CEC Specifications for Sinotec USA LLC STS-390P-54DD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sinotec USA LLC STS-390P-54DD.

Official California Energy Commission (NREL SAM) test parameters for Sinotec USA LLC STS-390P-54DD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 365.9 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 12.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.246 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.1% (1.94 m2) Array roof footprint density
Cell Count & Technology 108 cells (Mono-c-Si) Monofacial backsheet

How Many Sinotec USA LLC STS-390P-54DD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sinotec USA LLC STS-390P-54DD (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 334 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 439 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 543 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Sinotec USA LLC Series?

All closely matched Sinotec USA LLC wattages and cosmetic trims sharing the Sinotec USA LLC STS-390P-54DD architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Sinotec USA LLC STS-390P-54DD wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sinotec USA LLC STS-385P-54DD 385.0 W 361.1 W 36.6 V 30.7 V 19.85%
Sinotec USA LLC STS-390P-54DD 390.0 W 365.9 W 36.8 V 30.9 V 20.1%
Sinotec USA LLC STS-395P-54DD 395.0 W 370.8 W 37.0 V 31.1 V 20.36%

How Many Sinotec USA LLC STS-390P-54DD Modules Fit in a Cold-Weather String?

Maximum series module counts for Sinotec USA LLC STS-390P-54DD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.8V and beta_Voc=-0.246%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.87 V 14 panels 572.2 V 24 panels
-10 C (14 F) 39.97 V 15 panels 599.5 V 25 panels
0 C (32 F) 39.06 V 15 panels 585.9 V 25 panels
25 C (77 F STC) 36.8 V 16 panels 588.8 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Sinotec USA LLC STS-390P-54DD?

Alternative CEC solar modules from competing brands near Sinotec USA LLC STS-390P-54DD (390.0 W), including Apollo Renewables Inc Apollo-M754BH-390BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M754BH-390BB
Apollo Renewables Inc
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
AXITEC AC-390MH/108VB
AXITEC
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
ELITE Solar ET-M754BH390BB
ELITE Solar
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
390.0 W Tie (0 W) 36.45 V 20.53% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sinotec USA LLC STS-390P-54DD?

Evaluate Sinotec USA LLC STS-390P-54DD (390.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sinotec USA LLC STS-390P-54DD reaches 40.87 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Sinotec USA LLC STS-390P-54DD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sinotec USA LLC STS-390P-54DD 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-390BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sinotec USA LLC STS-390P-54DD by Sinotec USA LLC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Sinotec USA LLC STS-390P-54DD?

Multiplying Sinotec USA LLC STS-390P-54DD's 13.34 A short-circuit current by 1.56 equals 20.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Sinotec USA LLC STS-390P-54DD pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 39.97 V cold Voc at 14 F and handles 13.34 A Isc; string inverters cap Sinotec USA LLC STS-390P-54DD at 15 panels on 600 V.

Is Sinotec USA LLC STS-390P-54DD eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sinotec USA LLC STS-390P-54DD rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.