Sinotec USA LLC STS-390P-54DD is a 390.0 W STC (365.9 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.1% efficiency, 36.8 V Voc at 25 C, and 39.97 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 365.9 W
- Voc @ 25C
- 36.8 V
- Efficiency
- 20.1%
How Does Sinotec USA LLC STS-390P-54DD Compare Against Peer CEC Listings?
How Sinotec USA LLC Sinotec USA LLC STS-390P-54DD handles rooftop heat (365.9 W PTC), 8 kW sizing, and cold winter string voltage.
Sinotec USA LLC builds the Sinotec USA LLC STS-390P-54DD (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). Compared against Apollo Renewables Inc Apollo-M754BH-390BB (390.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Lower 36.8 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 20.81 A overcurrent floor served by a 25 A breaker.
Where Does Sinotec USA LLC STS-390P-54DD Fall Across Listed CEC Models?
Where Sinotec USA LLC STS-390P-54DD (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Sinotec USA LLC STS-390P-54DD?
Percentile placement of Sinotec USA LLC STS-390P-54DD across power density (201.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Sinotec USA LLC STS-390P-54DD?
Four critical engineering numbers homeowners and solar installers check first when reviewing Sinotec USA LLC STS-390P-54DD specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.1% Aperture Efficiency
Power density 201.0 W/m2 (0.19 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.97 V at -10 C (599.5 V string) and 40.87 V at -20 C (14 max).
21 Panels = 8,190 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.8 * (1 + (-0.246/100) * (-10 - 25)) = 39.97 V | OCPD = 1.56 * 13.34 = 20.81 A
Inputs from CEC Modules.csv for Sinotec USA LLC STS-390P-54DD: Voc=36.8 V, beta_Voc=-0.246%/C, Isc=13.34 A, STC=390.0 W, Area=1.94 m2.
Result: 15 panels max on 600 V (599.5 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for Sinotec USA LLC STS-390P-54DD?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sinotec USA LLC STS-390P-54DD.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.9 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.9 V / 12.62 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.246 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.1% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 108 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sinotec USA LLC STS-390P-54DD Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sinotec USA LLC STS-390P-54DD (390.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 334 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 439 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 543 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Sinotec USA LLC Series?
All closely matched Sinotec USA LLC wattages and cosmetic trims sharing the Sinotec USA LLC STS-390P-54DD architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Sinotec USA LLC STS-385P-54DD | 385.0 W | 361.1 W | 36.6 V | 30.7 V | 19.85% |
| Sinotec USA LLC STS-390P-54DD | 390.0 W | 365.9 W | 36.8 V | 30.9 V | 20.1% |
| Sinotec USA LLC STS-395P-54DD | 395.0 W | 370.8 W | 37.0 V | 31.1 V | 20.36% |
How Many Sinotec USA LLC STS-390P-54DD Modules Fit in a Cold-Weather String?
Maximum series module counts for Sinotec USA LLC STS-390P-54DD from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.87 V | 14 panels | 572.2 V | 24 panels |
| -10 C (14 F) | 39.97 V | 15 panels | 599.5 V | 25 panels |
| 0 C (32 F) | 39.06 V | 15 panels | 585.9 V | 25 panels |
| 25 C (77 F STC) | 36.8 V | 16 panels | 588.8 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Sinotec USA LLC STS-390P-54DD?
Alternative CEC solar modules from competing brands near Sinotec USA LLC STS-390P-54DD (390.0 W), including Apollo Renewables Inc Apollo-M754BH-390BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M754BH-390BB Apollo Renewables Inc |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| AXITEC AC-390MH/108VB AXITEC |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| ELITE Solar ET-M754BH390BB ELITE Solar |
390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
390.0 W | Tie (0 W) | 36.45 V | 20.53% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Sinotec USA LLC STS-390P-54DD?
Evaluate Sinotec USA LLC STS-390P-54DD (390.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sinotec USA LLC STS-390P-54DD reaches 40.87 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sinotec USA LLC STS-390P-54DD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sinotec USA LLC STS-390P-54DD 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Apollo Renewables Inc Apollo-M754BH-390BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sinotec USA LLC STS-390P-54DD by Sinotec USA LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sinotec USA LLC STS-390P-54DD?
Multiplying Sinotec USA LLC STS-390P-54DD's 13.34 A short-circuit current by 1.56 equals 20.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Sinotec USA LLC STS-390P-54DD pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 39.97 V cold Voc at 14 F and handles 13.34 A Isc; string inverters cap Sinotec USA LLC STS-390P-54DD at 15 panels on 600 V.
Is Sinotec USA LLC STS-390P-54DD eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sinotec USA LLC STS-390P-54DD rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)