Silfab Solar Inc SIL290ML is a 290.0 W STC (262.3 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 17.79% efficiency, 39.6 V Voc at 25 C, and 43.47 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 262.3 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 17.79%
How Does Silfab Solar Inc SIL290ML Compare Against Peer CEC Listings?
Solar engineering breakdown for Silfab Solar Inc SIL290ML: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Silfab Solar Inc and peers, Silfab Solar Inc SIL290ML stands 120.0 W below the 410.0 W Mono-c-Si median and typical 90.4% PTC-to-STC thermal output (262.3 W real-world rating). Sizing 6 kW (21 panels) to 10 kW (35 panels) yields $1,524-$2,540/yr in baseline US bill offset. Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Silfab Solar Inc SIL290ML Fall Across Listed CEC Models?
Distribution marker showing Silfab Solar Inc SIL290ML (290.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Silfab Solar Inc SIL290ML?
Dataset percentiles tracking Silfab Solar Inc SIL290ML power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Silfab Solar Inc SIL290ML?
Benchmark highlights for Silfab Solar Inc SIL290ML covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.79% Aperture Efficiency
Power density 177.9 W/m2 (2.12 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.47 V at -10 C (565.1 V string) and 44.57 V at -20 C (13 max).
28 Panels = 8,120 W STC
Occupies 45.6 m2 (491 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 14.88 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.279/100) * (-10 - 25)) = 43.47 V | OCPD = 1.56 * 9.54 = 14.88 A
Inputs from CEC Modules.csv for Silfab Solar Inc SIL290ML: Voc=39.6 V, beta_Voc=-0.279%/C, Isc=9.54 A, STC=290.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (565.1 V); 28 panels for 8 kW (491 sq ft).
What Are the Published CEC Specifications for Silfab Solar Inc SIL290ML?
Official CEC datasheet figures for Silfab Solar Inc SIL290ML (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 262.3 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.4 V / 8.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.79% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Silfab Solar Inc SIL290ML Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Silfab Solar Inc SIL290ML modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 368 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 491 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 614 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This Silfab Solar Inc Series?
Consolidated Silfab Solar Inc wattage variants sharing the Silfab Solar Inc SIL290ML mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Silfab Solar Inc SIL285ML | 285.0 W | 257.7 W | 39.1 V | 32.0 V | 17.48% |
| Silfab Solar Inc SIL290ML | 290.0 W | 262.3 W | 39.6 V | 32.4 V | 17.79% |
| Silfab Solar Inc SIL295ML | 295.0 W | 267.0 W | 40.0 V | 32.7 V | 18.1% |
How Many Silfab Solar Inc SIL290ML Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Silfab Solar Inc SIL290ML (43.47 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.57 V | 13 panels | 579.4 V | 22 panels |
| -10 C (14 F) | 43.47 V | 13 panels | 565.1 V | 23 panels |
| 0 C (32 F) | 42.36 V | 14 panels | 593.0 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SIL290ML?
Competing CEC solar panels closest to Silfab Solar Inc SIL290ML in nameplate wattage and Voc, starting with DualSun SAS DualSun 290M-60-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | Tie (0 W) | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| CertainTeed CT290M11-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
| AXITEC AC-290M/60S AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SIL290ML?
Evaluate Silfab Solar Inc SIL290ML (290.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SIL290ML reaches 44.57 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 491 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (491 sq ft).
- 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SIL290ML carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Silfab Solar Inc SIL290ML 8 kW Residential Fit
Needs 28 modules (491 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 290M-60-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Silfab Solar Inc SIL290ML by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Silfab Solar Inc SIL290ML?
Multiplying Silfab Solar Inc SIL290ML's 9.54 A short-circuit current by 1.56 equals 14.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Silfab Solar Inc SIL290ML pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.47 V cold Voc at 14 F and handles 9.54 A Isc; string inverters cap Silfab Solar Inc SIL290ML at 13 panels on 600 V.
Is Silfab Solar Inc SIL290ML eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Silfab Solar Inc SIL290ML rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)