Silfab Solar Inc SIL-505HN is a 505.0 W STC (465.8 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 22.18% efficiency, 54.51 V Voc at 25 C, and 60.29 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 505.0 W
- PTC Wattage
- 465.8 W
- Voc @ 25C
- 54.51 V
- Efficiency
- 22.18%
How Does Silfab Solar Inc SIL-505HN Compare Against Peer CEC Listings?
Engineering position of Silfab Solar Inc SIL-505HN (505.0 W STC) vs. CSI Solar Co Ltd CS3Y-505MS across 5,889 CEC Mono-c-Si solar modules.
Ranking #4,444 across 21,677 CEC solar panels (top 20.8%; higher than 79.2% of peers), Silfab Solar Inc SIL-505HN operates as a modern high-density residential and light-commercial module sitting 95.0 W above the 410.0 W Mono-c-Si median. Higher 54.51 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C). With strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677), 16 panels occupy 392 sq ft and offset roughly $2,022/yr at average US rates (or $3,420/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Silfab Solar Inc SIL-505HN Fall Across Listed CEC Models?
Plots Silfab Solar Inc SIL-505HN at 505.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Silfab Solar Inc SIL-505HN?
Benchmarks Silfab Solar Inc SIL-505HN on STC wattage, thermal PTC/STC retention, and 22.18 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Silfab Solar Inc SIL-505HN?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Silfab Solar Inc SIL-505HN by Silfab Solar Inc.
Top 20.8% STC Output
505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.18% Aperture Efficiency
Power density 221.8 W/m2 (2.27 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 60.29 V at -10 C (542.6 V string) and 61.94 V at -20 C (9 max).
16 Panels = 8,080 W STC
Occupies 36.4 m2 (392 sq ft) producing 7,453 W PTC; NEC 690.8 OCPD floor is 17.96 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 54.51 * (1 + (-0.303/100) * (-10 - 25)) = 60.29 V | OCPD = 1.56 * 11.51 = 17.96 A
Inputs from CEC Modules.csv for Silfab Solar Inc SIL-505HN: Voc=54.51 V, beta_Voc=-0.303%/C, Isc=11.51 A, STC=505.0 W, Area=2.277 m2.
Result: 9 panels max on 600 V (542.6 V); 16 panels for 8 kW (392 sq ft).
What Are the Published CEC Specifications for Silfab Solar Inc SIL-505HN?
Laboratory test ratings recorded for Silfab Solar Inc SIL-505HN (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 505.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 465.8 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 54.51 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.65 V / 11.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.18% (2.277 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Silfab Solar Inc SIL-505HN Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (392 sq ft at 8 kW), and estimated Year-1 electric bill offset for Silfab Solar Inc SIL-505HN.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.06 kW | 294 sq ft | $1,517 | $2,565 |
| 8 kW Class | 16 | 8.08 kW | 392 sq ft | $2,022 | $3,420 |
| 10 kW Class | 20 | 10.1 kW | 490 sq ft | $2,528 | $4,275 |
Which Sibling Wattage & Trim Variants Belong to This Silfab Solar Inc Series?
Sibling wattage bins and frame colors grouped with Silfab Solar Inc SIL-505HN under Silfab Solar Inc to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Silfab Solar Inc SIL-500HN | 500.0 W | 461.1 W | 54.33 V | 45.51 V | 21.96% |
| Silfab Solar Inc SIL-505HN | 505.0 W | 465.8 W | 54.51 V | 45.65 V | 22.18% |
How Many Silfab Solar Inc SIL-505HN Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Silfab Solar Inc SIL-505HN (beta_Voc -0.303%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 61.94 V | 9 panels | 557.5 V | 16 panels |
| -10 C (14 F) | 60.29 V | 9 panels | 542.6 V | 16 panels |
| 0 C (32 F) | 58.64 V | 10 panels | 586.4 V | 17 panels |
| 25 C (77 F STC) | 54.51 V | 11 panels | 599.6 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SIL-505HN?
Closest cross-brand CEC competitors to Silfab Solar Inc SIL-505HN matched near 505.0 W STC and 54.51 V Voc, led by CSI Solar Co Ltd CS3Y-505MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-505MS CSI Solar Co Ltd |
505.0 W | Tie (0 W) | 53.9 V | 22.05% | 93.7% |
| Bila Solar Inc BF510J-12X12UW Bila Solar Inc |
510.0 W | +5.0 W | 49.14 V | 18.96% | 93.2% |
| Bila Solar Inc DF510J-12X12UW Bila Solar Inc |
510.0 W | +5.0 W | 49.1 V | 18.96% | 93.6% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 Jiangsu Runergy New Energy Technology Co Ltd |
505.0 W | Tie (0 W) | 45.72 V | 29.88% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SIL-505HN?
Evaluate Silfab Solar Inc SIL-505HN (505.0 W STC, 54.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SIL-505HN reaches 61.94 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 392 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (392 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SIL-505HN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Silfab Solar Inc SIL-505HN 8 kW Residential Fit
Needs 16 modules (392 sq ft) with a 20 A string OCPD, offsetting ~$2,022/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 465.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Silfab Solar Inc SIL-505HN by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Silfab Solar Inc SIL-505HN panels fit on a 600 V winter solar string?
At -10 C (14 F), Silfab Solar Inc SIL-505HN cold Voc rises from 54.51 V to 60.29 V (beta_Voc -0.303%/C), capping a 600 V string at 9 panels (542.6 V).
How much roof area does an 8 kW array of Silfab Solar Inc SIL-505HN need?
An 8 kW DC system uses 16 Silfab Solar Inc SIL-505HN modules (8,080 W STC / 7,453 W PTC), covering roughly 392 sq ft and saving ~$2,022/yr at 18.54 c/kWh.
How does Silfab Solar Inc SIL-505HN compare against CSI Solar Co Ltd CS3Y-505MS?
Silfab Solar Inc SIL-505HN outputs 505.0 W STC (54.51 V Voc, rank #4,444 of 21,677), while CSI Solar Co Ltd CS3Y-505MS delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)