Skip to main content
WireAndSun
Calculators
CEC PV Module

Silfab Solar Inc SIL-410HU — CEC Solar Module Specifications

Manufacturer: Silfab Solar Inc Registry: CEC Verified Engineering Specification

Silfab Solar Inc SIL-410HU is a 410.0 W STC (385.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.92% efficiency, 49.12 V Voc at 25 C, and 53.26 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
385.2 W
Voc @ 25C
49.12 V
Efficiency
20.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Silfab Solar Inc SIL-410HU Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Silfab Solar Inc SIL-410HU (Mono-c-Si) residential solar systems.

Homeowners evaluating Silfab Solar Inc SIL-410HU need 15 panels for 6 kW or 20 panels (422 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.241%/C) pushes open-circuit voltage to 53.26 V at 14 F and 54.45 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Silfab Solar Inc SIL-410HU Fall Across Listed CEC Models?

Comparison of Silfab Solar Inc SIL-410HU (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Silfab Solar Inc SIL-410HU (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSilfab Solar Inc S: 410.0 W

What Dataset Percentiles Define Silfab Solar Inc SIL-410HU?

Relative ranking of Silfab Solar Inc SIL-410HU across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.

Silfab Solar Inc SIL-410HU Engineering BenchmarksPercentile comparison of Silfab Solar Inc SIL-410HU wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.0%Module Efficiency20.92%

What Do the Dataset Ranks Show for Silfab Solar Inc SIL-410HU?

Summary of Silfab Solar Inc SIL-410HU output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,759

20.92% Aperture Efficiency

Power density 209.2 W/m2 (1.01 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.26 V at -10 C (585.9 V string) and 54.45 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,704 W PTC; NEC 690.8 OCPD floor is 16.29 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.12 * (1 + (-0.241/100) * (-10 - 25)) = 53.26 V | OCPD = 1.56 * 10.44 = 16.29 A

Inputs from CEC Modules.csv for Silfab Solar Inc SIL-410HU: Voc=49.12 V, beta_Voc=-0.241%/C, Isc=10.44 A, STC=410.0 W, Area=1.96 m2.

Result: 11 panels max on 600 V (585.9 V); 20 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for Silfab Solar Inc SIL-410HU?

Complete CEC test sheet for Silfab Solar Inc SIL-410HU including Isc (10.44 A), Voc (49.12 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Silfab Solar Inc SIL-410HU.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 385.2 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.12 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.44 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.88 V / 10.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.92% (1.96 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Silfab Solar Inc SIL-410HU Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Silfab Solar Inc SIL-410HU.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 316 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 422 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 527 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Silfab Solar Inc Series?

Related Silfab Solar Inc power steps and black/silver trims consolidated into this Silfab Solar Inc SIL-410HU series guide.

Sibling CEC listings grouped into the Silfab Solar Inc SIL-410HU wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Silfab Solar Inc SIL-400HU 400.0 W 375.6 W 48.71 V 40.45 V 20.41%
Silfab Solar Inc SIL-405HU 405.0 W 380.4 W 48.91 V 40.67 V 20.66%
Silfab Solar Inc SIL-410HU 410.0 W 385.2 W 49.12 V 40.88 V 20.92%
Silfab Solar Inc SIL-415HU 415.0 W 390.0 W 49.32 V 41.1 V 21.17%
Silfab Solar Inc SIL-420HU 420.0 W 394.9 W 49.52 V 41.32 V 21.43%

How Many Silfab Solar Inc SIL-410HU Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Silfab Solar Inc SIL-410HU (49.12 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.12V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.45 V 11 panels 599.0 V 18 panels
-10 C (14 F) 53.26 V 11 panels 585.9 V 18 panels
0 C (32 F) 52.08 V 11 panels 572.9 V 19 panels
25 C (77 F STC) 49.12 V 12 panels 589.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SIL-410HU?

Four comparable CEC modules such as BYD Company Limited BYD400MIK-36 (410.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD400MIK-36
BYD Company Limited
410.0 W Tie (0 W) 49.21 V 20.4% 94.0%
AXITEC AC-410MB/144V
AXITEC
410.0 W Tie (0 W) 49.3 V 21.03% 93.0%
AXITEC AC-410MH/144V
AXITEC
410.0 W Tie (0 W) 48.91 V 20.71% 93.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SIL-410HU?

Evaluate Silfab Solar Inc SIL-410HU (410.0 W STC, 49.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SIL-410HU reaches 54.45 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 422 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SIL-410HU carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Silfab Solar Inc SIL-410HU 8 kW Residential Fit

Needs 20 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD400MIK-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 385.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Silfab Solar Inc SIL-410HU by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Silfab Solar Inc SIL-410HU PTC wattage (385.2 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 385.2 W PTC (94.0% retention) across Silfab Solar Inc SIL-410HU's 1.96 m2 aperture.

Who should skip Silfab Solar Inc SIL-410HU on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Silfab Solar Inc SIL-410HU panels (422 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD400MIK-36.

What is the 1,000 V commercial string limit for Silfab Solar Inc SIL-410HU?

On 1,000 V commercial inverters at -10 C (53.26 V cold Voc), Silfab Solar Inc SIL-410HU fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Silfab Solar Inc SIL-410HU.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.