Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V is a 360.0 W STC (337.5 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.27% efficiency, 48.0 V Voc at 25 C, and 52.75 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 337.5 W
- Voc @ 25C
- 48.0 V
- Efficiency
- 18.27%
How Does Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V Compare Against Peer CEC Listings?
How Shenglong PV-tech (Cambodia) Co LTD Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V handles rooftop heat (337.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V exhibits 9.79 A short-circuit current, requiring a 15.27 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #12,385 of 21,677 (50.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 45.3 m2 for an 8 kW system (28 panels for 10 kW). Higher 48.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V Fall Across Listed CEC Models?
Where Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
Percentile placement of Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V across power density (182.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
Four critical engineering numbers homeowners and solar installers check first when reviewing Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V specifications.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.27% Aperture Efficiency
Power density 182.7 W/m2 (1.64 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.75 V at -10 C (580.2 V string) and 54.11 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 45.3 m2 (488 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 15.27 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.0 * (1 + (-0.283/100) * (-10 - 25)) = 52.75 V | OCPD = 1.56 * 9.79 = 15.27 A
Inputs from CEC Modules.csv for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V: Voc=48.0 V, beta_Voc=-0.283%/C, Isc=9.79 A, STC=360.0 W, Area=1.97 m2.
Result: 11 panels max on 600 V (580.2 V); 23 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 337.5 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.2 V / 9.18 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.27% (1.97 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V (360.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 360 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 488 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 594 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Shenglong PV-tech (Cambodia) Co LTD Series?
All closely matched Shenglong PV-tech (Cambodia) Co LTD wattages and cosmetic trims sharing the Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shenglong PV-tech (Cambodia) Co LTD GLSM350M-72H-V | 350.0 W | 327.9 W | 47.5 V | 38.8 V | 17.77% |
| Shenglong PV-tech (Cambodia) Co LTD GLSM355M-72H-V | 355.0 W | 332.7 W | 47.8 V | 39.0 V | 18.02% |
| Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V | 360.0 W | 337.5 W | 48.0 V | 39.2 V | 18.27% |
| Shenglong PV-tech (Cambodia) Co LTD GLSM365M-72H-V | 365.0 W | 342.3 W | 48.2 V | 39.4 V | 18.53% |
| Shenglong PV-tech (Cambodia) Co LTD GLSM370M-72H-V | 370.0 W | 347.1 W | 48.4 V | 39.6 V | 18.78% |
How Many Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V Modules Fit in a Cold-Weather String?
Maximum series module counts for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.11 V | 11 panels | 595.2 V | 18 panels |
| -10 C (14 F) | 52.75 V | 11 panels | 580.2 V | 18 panels |
| 0 C (32 F) | 51.4 V | 11 panels | 565.4 V | 19 panels |
| 25 C (77 F STC) | 48.0 V | 12 panels | 576.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
Alternative CEC solar modules from competing brands near Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V (360.0 W), including Advance Power API-M360.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M360 Advance Power |
360.0 W | Tie (0 W) | 47.56 V | 18.56% | 91.7% |
| Auxin Solar AXN6M612T360 Auxin Solar |
360.0 W | Tie (0 W) | 47.56 V | 18.55% | 91.7% |
| Boviet Solar Technology Co Ltd BVM6612M-360 Boviet Solar Technology Co Ltd |
360.0 W | Tie (0 W) | 47.5 V | 18.56% | 92.3% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
Evaluate Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V (360.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V reaches 54.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V 8 kW Residential Fit
Needs 23 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M360.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 337.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V by Shenglong PV-tech (Cambodia) Co LTD grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V PTC wattage (337.5 W) lower than STC (360.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 337.5 W PTC (93.8% retention) across Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V's 1.97 m2 aperture.
Who should skip Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V panels (488 sq ft) leave unusable roof gaps vs. Advance Power API-M360.
What is the 1,000 V commercial string limit for Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V?
On 1,000 V commercial inverters at -10 C (52.75 V cold Voc), Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)