Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V is a 345.0 W STC (323.1 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.51% efficiency, 47.2 V Voc at 25 C, and 51.88 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 323.1 W
- Voc @ 25C
- 47.2 V
- Efficiency
- 17.51%
How Does Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V Compare Against Peer CEC Listings?
Engineering position of Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V (345.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-P6/72345 across 5,889 CEC Mono-c-Si solar modules.
Ranking #13,309 across 21,677 CEC solar panels (below all-CEC median; higher than 37.4% of peers), Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V operates as a compact residential or specialty off-grid module sitting 65.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 24 panels occupy 509 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V Fall Across Listed CEC Models?
Plots Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V at 345.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V?
Benchmarks Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V on STC wattage, thermal PTC/STC retention, and 17.51 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V by Shenglong PV-tech (Cambodia) Co LTD.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.51% Aperture Efficiency
Power density 175.1 W/m2 (2.40 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.88 V at -10 C (570.7 V string) and 53.21 V at -20 C (11 max).
24 Panels = 8,280 W STC
Occupies 47.3 m2 (509 sq ft) producing 7,754 W PTC; NEC 690.8 OCPD floor is 14.98 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.2 * (1 + (-0.283/100) * (-10 - 25)) = 51.88 V | OCPD = 1.56 * 9.6 = 14.98 A
Inputs from CEC Modules.csv for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V: Voc=47.2 V, beta_Voc=-0.283%/C, Isc=9.6 A, STC=345.0 W, Area=1.97 m2.
Result: 11 panels max on 600 V (570.7 V); 24 panels for 8 kW (509 sq ft).
What Are the Published CEC Specifications for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V?
Laboratory test ratings recorded for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 323.1 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.6 V / 8.94 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.51% (1.97 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (509 sq ft at 8 kW), and estimated Year-1 electric bill offset for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 382 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 509 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 615 sq ft | $2,505 | $4,236 |
How Many Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V (beta_Voc -0.283%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.21 V | 11 panels | 585.3 V | 18 panels |
| -10 C (14 F) | 51.88 V | 11 panels | 570.7 V | 19 panels |
| 0 C (32 F) | 50.54 V | 11 panels | 555.9 V | 19 panels |
| 25 C (77 F STC) | 47.2 V | 12 panels | 566.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V?
Closest cross-brand CEC competitors to Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V matched near 345.0 W STC and 47.2 V Voc, led by GCL System Integration Technology Co Ltd GCL-P6/72345.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V?
Evaluate Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V (345.0 W STC, 47.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V reaches 53.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 509 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (509 sq ft).
- 2026 tax credit baseline: cash residential installs of Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V 8 kW Residential Fit
Needs 24 modules (509 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72345.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 323.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V by Shenglong PV-tech (Cambodia) Co LTD grounded in CEC test data and NEC 690.7/690.8 limits.
How many Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V panels fit on a 600 V winter solar string?
At -10 C (14 F), Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V cold Voc rises from 47.2 V to 51.88 V (beta_Voc -0.283%/C), capping a 600 V string at 11 panels (570.7 V).
How much roof area does an 8 kW array of Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V need?
An 8 kW DC system uses 24 Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V modules (8,280 W STC / 7,754 W PTC), covering roughly 509 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V compare against GCL System Integration Technology Co Ltd GCL-P6/72345?
Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V outputs 345.0 W STC (47.2 V Voc, rank #13,309 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/72345 delivers 345.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)