SEG Solar Inc SEG-535-BMA-TB is a 535.0 W STC (501.9 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.4 V Voc at 25 C, and 53.96 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 501.9 W
- Voc @ 25C
- 49.4 V
- Efficiency
- 20.74%
How Does SEG Solar Inc SEG-535-BMA-TB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SEG Solar Inc SEG-535-BMA-TB (Mono-c-Si) residential solar systems.
Homeowners evaluating SEG Solar Inc SEG-535-BMA-TB need 12 panels for 6 kW or 15 panels (417 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.264%/C) pushes open-circuit voltage to 53.96 V at 14 F and 55.27 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does SEG Solar Inc SEG-535-BMA-TB Fall Across Listed CEC Models?
Comparison of SEG Solar Inc SEG-535-BMA-TB (535.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define SEG Solar Inc SEG-535-BMA-TB?
Relative ranking of SEG Solar Inc SEG-535-BMA-TB across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for SEG Solar Inc SEG-535-BMA-TB?
Summary of SEG Solar Inc SEG-535-BMA-TB output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.96 V at -10 C (593.6 V string) and 55.27 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,528 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.4 * (1 + (-0.264/100) * (-10 - 25)) = 53.96 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for SEG Solar Inc SEG-535-BMA-TB: Voc=49.4 V, beta_Voc=-0.264%/C, Isc=13.7 A, STC=535.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (593.6 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for SEG Solar Inc SEG-535-BMA-TB?
Complete CEC test sheet for SEG Solar Inc SEG-535-BMA-TB including Isc (13.7 A), Voc (49.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 501.9 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.29 V / 12.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many SEG Solar Inc SEG-535-BMA-TB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SEG Solar Inc SEG-535-BMA-TB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 333 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 417 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 528 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?
Related SEG Solar Inc power steps and black/silver trims consolidated into this SEG Solar Inc SEG-535-BMA-TB series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SEG Solar Inc SEG-525-BMA-TB | 525.0 W | 492.3 W | 49.2 V | 40.78 V | 20.35% |
| SEG Solar Inc SEG-530-BMA-TB | 530.0 W | 497.1 W | 49.33 V | 41.03 V | 20.54% |
| SEG Solar Inc SEG-535-BMA-TB | 535.0 W | 501.9 W | 49.4 V | 41.29 V | 20.74% |
| SEG Solar Inc SEG-540-BMA-TB | 540.0 W | 506.7 W | 49.5 V | 41.55 V | 20.93% |
| SEG Solar Inc SEG-545-BMA-TB | 545.0 W | 511.5 W | 49.6 V | 41.81 V | 21.12% |
How Many SEG Solar Inc SEG-535-BMA-TB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for SEG Solar Inc SEG-535-BMA-TB (49.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.27 V | 10 panels | 552.7 V | 18 panels |
| -10 C (14 F) | 53.96 V | 11 panels | 593.6 V | 18 panels |
| 0 C (32 F) | 52.66 V | 11 panels | 579.3 V | 18 panels |
| 25 C (77 F STC) | 49.4 V | 12 panels | 592.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-535-BMA-TB?
Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM72M-HC-535 (535.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM72M-HC-535 Elin Energy (Sirius PV) |
535.0 W | Tie (0 W) | 49.4 V | 20.9% | 94.3% |
| GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 GOLDI SUN PRIVATE LIMITED |
535.0 W | Tie (0 W) | 49.39 V | 20.74% | 93.9% |
| GOLDI SUN PRIVATE LIMITED GS10-M144-WF-535 GOLDI SUN PRIVATE LIMITED |
535.0 W | Tie (0 W) | 49.39 V | 20.74% | 93.6% |
| BYD Company Limited BYD535MLTK-36 BYD Company Limited |
535.0 W | Tie (0 W) | 49.42 V | 20.74% | 92.9% |
What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-535-BMA-TB?
Evaluate SEG Solar Inc SEG-535-BMA-TB (535.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-535-BMA-TB reaches 55.27 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-535-BMA-TB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SEG Solar Inc SEG-535-BMA-TB 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM72M-HC-535.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 501.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SEG Solar Inc SEG-535-BMA-TB by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is SEG Solar Inc SEG-535-BMA-TB PTC wattage (501.9 W) lower than STC (535.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 501.9 W PTC (93.8% retention) across SEG Solar Inc SEG-535-BMA-TB's 2.58 m2 aperture.
Who should skip SEG Solar Inc SEG-535-BMA-TB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SEG Solar Inc SEG-535-BMA-TB panels (417 sq ft) leave unusable roof gaps vs. Elin Energy (Sirius PV) ELNSM72M-HC-535.
What is the 1,000 V commercial string limit for SEG Solar Inc SEG-535-BMA-TB?
On 1,000 V commercial inverters at -10 C (53.96 V cold Voc), SEG Solar Inc SEG-535-BMA-TB fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SEG Solar Inc SEG-535-BMA-TB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)