SEG Solar Inc SEG-395-BMD-BG is a 395.0 W STC (373.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.15% efficiency, 37.01 V Voc at 25 C, and 40.13 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
373.4 W
Voc @ 25C
37.01 V
Efficiency
20.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-395-BMD-BG Compare Against Peer CEC Listings?

Engineering position of SEG Solar Inc SEG-395-BMD-BG (395.0 W STC) vs. AXITEC AC-395MBT/108V across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, SEG Solar Inc SEG-395-BMD-BG pairs strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677) with 37.01 V nominal Voc. An 8 kW residential build (8,295 W DC, 7,841 W PTC) saves ~$2,075/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer AXITEC AC-395MBT/108V offers a 395.0 W alternative.

Where Does SEG Solar Inc SEG-395-BMD-BG Fall Across Listed CEC Models?

Plots SEG Solar Inc SEG-395-BMD-BG at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-395-BMD-BG (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 395.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-395-BMD-BG?

Benchmarks SEG Solar Inc SEG-395-BMD-BG on STC wattage, thermal PTC/STC retention, and 20.15 aperture conversion efficiency against CEC peers.

SEG Solar Inc SEG-395-BMD-BG Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-395-BMD-BG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention94.5%Module Efficiency20.15%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-395-BMD-BG?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SEG Solar Inc SEG-395-BMD-BG by SEG Solar Inc.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,939

20.15% Aperture Efficiency

Power density 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.13 V at -10 C (561.8 V string) and 41.02 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 41.2 m2 (443 sq ft) producing 7,841 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.01 * (1 + (-0.241/100) * (-10 - 25)) = 40.13 V | OCPD = 1.56 * 13.5 = 21.06 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-395-BMD-BG: Voc=37.01 V, beta_Voc=-0.241%/C, Isc=13.5 A, STC=395.0 W, Area=1.96 m2.

Result: 14 panels max on 600 V (561.8 V); 21 panels for 8 kW (443 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-395-BMD-BG?

Laboratory test ratings recorded for SEG Solar Inc SEG-395-BMD-BG (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-395-BMD-BG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 373.4 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.01 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.69 V / 12.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.15% (1.96 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many SEG Solar Inc SEG-395-BMD-BG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for SEG Solar Inc SEG-395-BMD-BG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 338 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 443 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 549 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Sibling wattage bins and frame colors grouped with SEG Solar Inc SEG-395-BMD-BG under SEG Solar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the SEG Solar Inc SEG-395-BMD-BG wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-390-BMD-BG 390.0 W 368.6 W 36.9 V 30.59 V 19.9%
SEG Solar Inc SEG-395-BMD-BG 395.0 W 373.4 W 37.01 V 30.69 V 20.15%

How Many SEG Solar Inc SEG-395-BMD-BG Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SEG Solar Inc SEG-395-BMD-BG (beta_Voc -0.241%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.01V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.02 V 14 panels 574.3 V 24 panels
-10 C (14 F) 40.13 V 14 panels 561.8 V 24 panels
0 C (32 F) 39.24 V 15 panels 588.6 V 25 panels
25 C (77 F STC) 37.01 V 16 panels 592.2 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-395-BMD-BG?

Closest cross-brand CEC competitors to SEG Solar Inc SEG-395-BMD-BG matched near 395.0 W STC and 37.01 V Voc, led by AXITEC AC-395MBT/108V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-395MBT/108V
AXITEC
395.0 W Tie (0 W) 37.0 V 20.47% 93.3%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-395
Elin Energy (Sirius PV)
395.0 W Tie (0 W) 37.02 V 20.36% 94.3%
Belinus Solar BV BE-M7-GG-108-395
Belinus Solar BV
395.0 W Tie (0 W) 37.03 V 20.26% 93.8%
ASTORIOS Holding Inc ASTR108BDG-395W-US
ASTORIOS Holding Inc
395.0 W Tie (0 W) 36.9 V 20.36% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-395-BMD-BG?

Evaluate SEG Solar Inc SEG-395-BMD-BG (395.0 W STC, 37.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-395-BMD-BG reaches 41.02 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (443 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-395-BMD-BG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-395-BMD-BG 8 kW Residential Fit

Needs 21 modules (443 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-395MBT/108V.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 373.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-395-BMD-BG by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SEG Solar Inc SEG-395-BMD-BG?

Multiplying SEG Solar Inc SEG-395-BMD-BG's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SEG Solar Inc SEG-395-BMD-BG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.13 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap SEG Solar Inc SEG-395-BMD-BG at 14 panels on 600 V.

Is SEG Solar Inc SEG-395-BMD-BG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SEG Solar Inc SEG-395-BMD-BG rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.