S-Energy Co Ltd SN345M-10 is a 345.0 W STC (317.8 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 18.24% efficiency, 45.3 V Voc at 25 C, and 49.76 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 317.8 W
- Voc @ 25C
- 45.3 V
- Efficiency
- 18.24%
How Does S-Energy Co Ltd SN345M-10 Compare Against Peer CEC Listings?
Solar engineering breakdown for S-Energy Co Ltd SN345M-10: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from S-Energy Co Ltd and peers, S-Energy Co Ltd SN345M-10 stands 65.0 W below the 410.0 W Mono-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,554-$2,505/yr in baseline US bill offset. Mid-range 45.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does S-Energy Co Ltd SN345M-10 Fall Across Listed CEC Models?
Distribution marker showing S-Energy Co Ltd SN345M-10 (345.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define S-Energy Co Ltd SN345M-10?
Dataset percentiles tracking S-Energy Co Ltd SN345M-10 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for S-Energy Co Ltd SN345M-10?
Benchmark highlights for S-Energy Co Ltd SN345M-10 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.24% Aperture Efficiency
Power density 182.4 W/m2 (1.67 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.76 V at -10 C (597.1 V string) and 51.03 V at -20 C (11 max).
24 Panels = 8,280 W STC
Occupies 45.4 m2 (489 sq ft) producing 7,627 W PTC; NEC 690.8 OCPD floor is 14.68 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.3 * (1 + (-0.281/100) * (-10 - 25)) = 49.76 V | OCPD = 1.56 * 9.41 = 14.68 A
Inputs from CEC Modules.csv for S-Energy Co Ltd SN345M-10: Voc=45.3 V, beta_Voc=-0.281%/C, Isc=9.41 A, STC=345.0 W, Area=1.891 m2.
Result: 12 panels max on 600 V (597.1 V); 24 panels for 8 kW (489 sq ft).
What Are the Published CEC Specifications for S-Energy Co Ltd SN345M-10?
Official CEC datasheet figures for S-Energy Co Ltd SN345M-10 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 317.8 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.5 V / 8.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.24% (1.891 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many S-Energy Co Ltd SN345M-10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many S-Energy Co Ltd SN345M-10 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 366 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 489 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 590 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?
Consolidated S-Energy Co Ltd wattage variants sharing the S-Energy Co Ltd SN345M-10 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| S-Energy Co Ltd SN340M-10 | 340.0 W | 313.1 W | 45.2 V | 38.1 V | 17.98% |
| S-Energy Co Ltd SN345M-10 | 345.0 W | 317.8 W | 45.3 V | 38.5 V | 18.24% |
How Many S-Energy Co Ltd SN345M-10 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SN345M-10 (49.76 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.03 V | 11 panels | 561.3 V | 19 panels |
| -10 C (14 F) | 49.76 V | 12 panels | 597.1 V | 20 panels |
| 0 C (32 F) | 48.48 V | 12 panels | 581.8 V | 20 panels |
| 25 C (77 F STC) | 45.3 V | 13 panels | 588.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SN345M-10?
Competing CEC solar panels closest to S-Energy Co Ltd SN345M-10 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6XH-345M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6XH-345M CSI Solar Co Ltd |
345.0 W | Tie (0 W) | 44.4 V | 18.65% | 92.8% |
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SN345M-10?
Evaluate S-Energy Co Ltd SN345M-10 (345.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SN345M-10 reaches 51.03 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 489 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (489 sq ft).
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SN345M-10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
S-Energy Co Ltd SN345M-10 8 kW Residential Fit
Needs 24 modules (489 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-345M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 317.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for S-Energy Co Ltd SN345M-10 by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SN345M-10?
Multiplying S-Energy Co Ltd SN345M-10's 9.41 A short-circuit current by 1.56 equals 14.68 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can S-Energy Co Ltd SN345M-10 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.76 V cold Voc at 14 F and handles 9.41 A Isc; string inverters cap S-Energy Co Ltd SN345M-10 at 12 panels on 600 V.
Is S-Energy Co Ltd SN345M-10 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SN345M-10 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)