S-Energy Co Ltd SL65-54BHJ-405V is a 405.0 W STC (377.7 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.88% efficiency, 37.36 V Voc at 25 C, and 40.8 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
377.7 W
Voc @ 25C
37.36 V
Efficiency
20.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does S-Energy Co Ltd SL65-54BHJ-405V Compare Against Peer CEC Listings?

Solar engineering breakdown for S-Energy Co Ltd SL65-54BHJ-405V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from S-Energy Co Ltd and peers, S-Energy Co Ltd SL65-54BHJ-405V stands 5.0 W below the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Lower 37.36 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does S-Energy Co Ltd SL65-54BHJ-405V Fall Across Listed CEC Models?

Distribution marker showing S-Energy Co Ltd SL65-54BHJ-405V (405.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where S-Energy Co Ltd SL65-54BHJ-405V (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCS-Energy Co Ltd SL: 405.0 W

What Dataset Percentiles Define S-Energy Co Ltd SL65-54BHJ-405V?

Dataset percentiles tracking S-Energy Co Ltd SL65-54BHJ-405V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

S-Energy Co Ltd SL65-54BHJ-405V Engineering BenchmarksPercentile comparison of S-Energy Co Ltd SL65-54BHJ-405V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.3%Module Efficiency20.88%

What Do the Dataset Ranks Show for S-Energy Co Ltd SL65-54BHJ-405V?

Benchmark highlights for S-Energy Co Ltd SL65-54BHJ-405V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.8 V at -10 C (571.2 V string) and 41.78 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,554 W PTC; NEC 690.8 OCPD floor is 21.5 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.36 * (1 + (-0.263/100) * (-10 - 25)) = 40.8 V | OCPD = 1.56 * 13.78 = 21.5 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SL65-54BHJ-405V: Voc=37.36 V, beta_Voc=-0.263%/C, Isc=13.78 A, STC=405.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (571.2 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for S-Energy Co Ltd SL65-54BHJ-405V?

Official CEC datasheet figures for S-Energy Co Ltd SL65-54BHJ-405V (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SL65-54BHJ-405V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.7 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.36 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.36 V / 12.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.88% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many S-Energy Co Ltd SL65-54BHJ-405V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many S-Energy Co Ltd SL65-54BHJ-405V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 313 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 418 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 522 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?

Consolidated S-Energy Co Ltd wattage variants sharing the S-Energy Co Ltd SL65-54BHJ-405V mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the S-Energy Co Ltd SL65-54BHJ-405V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
S-Energy Co Ltd SL65-54BHJ-400V 400.0 W 372.9 W 37.2 V 31.17 V 20.62%
S-Energy Co Ltd SL65-54BHJ-405V 405.0 W 377.7 W 37.36 V 31.36 V 20.88%
S-Energy Co Ltd SL65-54BHJ-410V 410.0 W 382.5 W 37.54 V 31.55 V 21.13%

How Many S-Energy Co Ltd SL65-54BHJ-405V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SL65-54BHJ-405V (40.8 V at 14 F).

Computed from Voc=37.36V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.78 V 14 panels 584.9 V 23 panels
-10 C (14 F) 40.8 V 14 panels 571.2 V 24 panels
0 C (32 F) 39.82 V 15 panels 597.3 V 25 panels
25 C (77 F STC) 37.36 V 16 panels 597.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SL65-54BHJ-405V?

Competing CEC solar panels closest to S-Energy Co Ltd SL65-54BHJ-405V in nameplate wattage and Voc, starting with Belinus Solar BV BE-M7-GG-108-405.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Belinus Solar BV BE-M7-GG-108-405
Belinus Solar BV
405.0 W Tie (0 W) 37.36 V 20.77% 93.8%
Aptos Solar Technology LLC DNA-108-BF10-405W
Aptos Solar Technology LLC
405.0 W Tie (0 W) 37.23 V 20.98% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W
Dehui Solar Power (Vietnam) CoLtd
405.0 W Tie (0 W) 37.23 V 20.98% 93.3%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
405.0 W Tie (0 W) 37.2 V 20.98% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SL65-54BHJ-405V?

Evaluate S-Energy Co Ltd SL65-54BHJ-405V (405.0 W STC, 37.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SL65-54BHJ-405V reaches 41.78 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SL65-54BHJ-405V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

S-Energy Co Ltd SL65-54BHJ-405V 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Belinus Solar BV BE-M7-GG-108-405.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 377.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SL65-54BHJ-405V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SL65-54BHJ-405V?

Multiplying S-Energy Co Ltd SL65-54BHJ-405V's 13.78 A short-circuit current by 1.56 equals 21.5 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can S-Energy Co Ltd SL65-54BHJ-405V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.8 V cold Voc at 14 F and handles 13.78 A Isc; string inverters cap S-Energy Co Ltd SL65-54BHJ-405V at 14 panels on 600 V.

Is S-Energy Co Ltd SL65-54BHJ-405V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SL65-54BHJ-405V rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.