Skip to main content
WireAndSun
Calculators
CEC PV Module

S-Energy Co Ltd SC25-72MCE-390V — CEC Solar Module Specifications

Manufacturer: S-Energy Co Ltd Registry: CEC Verified Engineering Specification

S-Energy Co Ltd SC25-72MCE-390V is a 390.0 W STC (361.2 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.6% efficiency, 48.5 V Voc at 25 C, and 52.9 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
361.2 W
Voc @ 25C
48.5 V
Efficiency
19.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does S-Energy Co Ltd SC25-72MCE-390V Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for S-Energy Co Ltd SC25-72MCE-390V (Mono-c-Si) residential solar systems.

S-Energy Co Ltd SC25-72MCE-390V delivers 196.0 W/m2 (0.31 percentage points below 19.91% CEC median) and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 54.15 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with CSI Solar Co Ltd CS3U-390MS (390.0 W).

Where Does S-Energy Co Ltd SC25-72MCE-390V Fall Across Listed CEC Models?

Comparison of S-Energy Co Ltd SC25-72MCE-390V (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where S-Energy Co Ltd SC25-72MCE-390V (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCS-Energy Co Ltd SC: 390.0 W

What Dataset Percentiles Define S-Energy Co Ltd SC25-72MCE-390V?

Relative ranking of S-Energy Co Ltd SC25-72MCE-390V across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.

S-Energy Co Ltd SC25-72MCE-390V Engineering BenchmarksPercentile comparison of S-Energy Co Ltd SC25-72MCE-390V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention92.6%Module Efficiency19.6%

What Do the Dataset Ranks Show for S-Energy Co Ltd SC25-72MCE-390V?

Summary of S-Energy Co Ltd SC25-72MCE-390V output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,845

19.6% Aperture Efficiency

Power density 196.0 W/m2 (0.31 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.9 V at -10 C (581.9 V string) and 54.15 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 41.8 m2 (450 sq ft) producing 7,585 W PTC; NEC 690.8 OCPD floor is 15.94 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.5 * (1 + (-0.259/100) * (-10 - 25)) = 52.9 V | OCPD = 1.56 * 10.22 = 15.94 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SC25-72MCE-390V: Voc=48.5 V, beta_Voc=-0.259%/C, Isc=10.22 A, STC=390.0 W, Area=1.99 m2.

Result: 11 panels max on 600 V (581.9 V); 21 panels for 8 kW (450 sq ft).

What Are the Published CEC Specifications for S-Energy Co Ltd SC25-72MCE-390V?

Complete CEC test sheet for S-Energy Co Ltd SC25-72MCE-390V including Isc (10.22 A), Voc (48.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SC25-72MCE-390V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 361.2 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.3 V / 9.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.6% (1.99 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many S-Energy Co Ltd SC25-72MCE-390V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using S-Energy Co Ltd SC25-72MCE-390V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 343 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 450 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 557 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?

Related S-Energy Co Ltd power steps and black/silver trims consolidated into this S-Energy Co Ltd SC25-72MCE-390V series guide.

Sibling CEC listings grouped into the S-Energy Co Ltd SC25-72MCE-390V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
S-Energy Co Ltd SC25-72MCE-380V 380.0 W 351.7 W 48.1 V 39.9 V 19.1%
S-Energy Co Ltd SC25-72MCE-385V 385.0 W 356.4 W 48.4 V 40.2 V 19.35%
S-Energy Co Ltd SC25-72MCE-390V 390.0 W 361.2 W 48.5 V 40.3 V 19.6%
S-Energy Co Ltd SC25-72MCE-395V 395.0 W 365.9 W 48.7 V 40.5 V 19.85%

How Many S-Energy Co Ltd SC25-72MCE-390V Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for S-Energy Co Ltd SC25-72MCE-390V (48.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.5V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.15 V 11 panels 595.6 V 18 panels
-10 C (14 F) 52.9 V 11 panels 581.9 V 18 panels
0 C (32 F) 51.64 V 11 panels 568.0 V 19 panels
25 C (77 F STC) 48.5 V 12 panels 582.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SC25-72MCE-390V?

Four comparable CEC modules such as CSI Solar Co Ltd CS3U-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 48.2 V 20.31% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W -5.0 W 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W -5.0 W 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W -5.0 W 48.45 V 19.35% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SC25-72MCE-390V?

Evaluate S-Energy Co Ltd SC25-72MCE-390V (390.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SC25-72MCE-390V reaches 54.15 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 450 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SC25-72MCE-390V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

S-Energy Co Ltd SC25-72MCE-390V 8 kW Residential Fit

Needs 21 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 361.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SC25-72MCE-390V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many S-Energy Co Ltd SC25-72MCE-390V panels fit on a 600 V winter solar string?

At -10 C (14 F), S-Energy Co Ltd SC25-72MCE-390V cold Voc rises from 48.5 V to 52.9 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (581.9 V).

How much roof area does an 8 kW array of S-Energy Co Ltd SC25-72MCE-390V need?

An 8 kW DC system uses 21 S-Energy Co Ltd SC25-72MCE-390V modules (8,190 W STC / 7,585 W PTC), covering roughly 450 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does S-Energy Co Ltd SC25-72MCE-390V compare against CSI Solar Co Ltd CS3U-390MS?

S-Energy Co Ltd SC25-72MCE-390V outputs 390.0 W STC (48.5 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS3U-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.