RNG International Inc RSP410D-BB-108 is a 410.0 W STC (386.9 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.46 V Voc at 25 C, and 41.25 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 386.9 W
- Voc @ 25C
- 37.46 V
- Efficiency
- 21.13%
How Does RNG International Inc RSP410D-BB-108 Compare Against Peer CEC Listings?
How RNG International Inc RNG International Inc RSP410D-BB-108 handles rooftop heat (386.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, RNG International Inc RSP410D-BB-108 exhibits 13.96 A short-circuit current, requiring a 21.78 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.46 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does RNG International Inc RSP410D-BB-108 Fall Across Listed CEC Models?
Where RNG International Inc RSP410D-BB-108 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define RNG International Inc RSP410D-BB-108?
Percentile placement of RNG International Inc RSP410D-BB-108 across power density (211.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for RNG International Inc RSP410D-BB-108?
Four critical engineering numbers homeowners and solar installers check first when reviewing RNG International Inc RSP410D-BB-108 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.13% Aperture Efficiency
Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.25 V at -10 C (577.5 V string) and 42.33 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,738 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.46 * (1 + (-0.289/100) * (-10 - 25)) = 41.25 V | OCPD = 1.56 * 13.96 = 21.78 A
Inputs from CEC Modules.csv for RNG International Inc RSP410D-BB-108: Voc=37.46 V, beta_Voc=-0.289%/C, Isc=13.96 A, STC=410.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (577.5 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for RNG International Inc RSP410D-BB-108?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for RNG International Inc RSP410D-BB-108.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 386.9 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.22 V / 13.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.289 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.13% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many RNG International Inc RSP410D-BB-108 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using RNG International Inc RSP410D-BB-108 (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 313 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 418 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 522 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This RNG International Inc Series?
All closely matched RNG International Inc wattages and cosmetic trims sharing the RNG International Inc RSP410D-BB-108 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| RNG International Inc RSP400D-BB-108 | 400.0 W | 377.2 W | 37.16 V | 31.02 V | 20.62% |
| RNG International Inc RSP405D-BB-108 | 405.0 W | 382.0 W | 37.31 V | 31.09 V | 20.88% |
| RNG International Inc RSP410D-BB-108 | 410.0 W | 386.9 W | 37.46 V | 31.22 V | 21.13% |
| RNG International Inc RSP415D-BB-108 | 415.0 W | 391.7 W | 37.54 V | 31.35 V | 21.39% |
| RNG International Inc RSP420D-BB-108 | 420.0 W | 396.5 W | 37.62 V | 31.48 V | 21.65% |
How Many RNG International Inc RSP410D-BB-108 Modules Fit in a Cold-Weather String?
Maximum series module counts for RNG International Inc RSP410D-BB-108 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.33 V | 14 panels | 592.6 V | 23 panels |
| -10 C (14 F) | 41.25 V | 14 panels | 577.5 V | 24 panels |
| 0 C (32 F) | 40.17 V | 14 panels | 562.4 V | 24 panels |
| 25 C (77 F STC) | 37.46 V | 16 panels | 599.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to RNG International Inc RSP410D-BB-108?
Alternative CEC solar modules from competing brands near RNG International Inc RSP410D-BB-108 (410.0 W), including Bluesun Solar CoLtd BSM410M10-54HPH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM410M10-54HPH Bluesun Solar CoLtd |
410.0 W | Tie (0 W) | 37.5 V | 20.99% | 93.3% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |
| Auxin Solar AXN10M410B Auxin Solar |
410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 37.34 V | 21.24% | 92.2% |
What Are the Design Limits and Best-Fit Uses for RNG International Inc RSP410D-BB-108?
Evaluate RNG International Inc RSP410D-BB-108 (410.0 W STC, 37.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), RNG International Inc RSP410D-BB-108 reaches 42.33 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of RNG International Inc RSP410D-BB-108 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
RNG International Inc RSP410D-BB-108 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Bluesun Solar CoLtd BSM410M10-54HPH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 386.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for RNG International Inc RSP410D-BB-108 by RNG International Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is RNG International Inc RSP410D-BB-108 PTC wattage (386.9 W) lower than STC (410.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 386.9 W PTC (94.4% retention) across RNG International Inc RSP410D-BB-108's 1.94 m2 aperture.
Who should skip RNG International Inc RSP410D-BB-108 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 RNG International Inc RSP410D-BB-108 panels (418 sq ft) leave unusable roof gaps vs. Bluesun Solar CoLtd BSM410M10-54HPH.
What is the 1,000 V commercial string limit for RNG International Inc RSP410D-BB-108?
On 1,000 V commercial inverters at -10 C (41.25 V cold Voc), RNG International Inc RSP410D-BB-108 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting RNG International Inc RSP410D-BB-108.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)