RNG International Inc RSP360D-BB-96 is a 360.0 W STC (339.6 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.81% efficiency, 33.43 V Voc at 25 C, and 36.81 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 339.6 W
- Voc @ 25C
- 33.43 V
- Efficiency
- 20.81%
How Does RNG International Inc RSP360D-BB-96 Compare Against Peer CEC Listings?
Solar engineering breakdown for RNG International Inc RSP360D-BB-96: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from RNG International Inc and peers, RNG International Inc RSP360D-BB-96 stands 50.0 W below the 410.0 W Mono-c-Si median and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Lower 33.43 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.
Where Does RNG International Inc RSP360D-BB-96 Fall Across Listed CEC Models?
Distribution marker showing RNG International Inc RSP360D-BB-96 (360.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define RNG International Inc RSP360D-BB-96?
Dataset percentiles tracking RNG International Inc RSP360D-BB-96 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for RNG International Inc RSP360D-BB-96?
Benchmark highlights for RNG International Inc RSP360D-BB-96 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.81% Aperture Efficiency
Power density 208.1 W/m2 (0.90 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.81 V at -10 C (589.0 V string) and 37.78 V at -20 C (15 max).
23 Panels = 8,280 W STC
Occupies 39.8 m2 (428 sq ft) producing 7,811 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.43 * (1 + (-0.289/100) * (-10 - 25)) = 36.81 V | OCPD = 1.56 * 13.5 = 21.06 A
Inputs from CEC Modules.csv for RNG International Inc RSP360D-BB-96: Voc=33.43 V, beta_Voc=-0.289%/C, Isc=13.5 A, STC=360.0 W, Area=1.73 m2.
Result: 16 panels max on 600 V (589.0 V); 23 panels for 8 kW (428 sq ft).
What Are the Published CEC Specifications for RNG International Inc RSP360D-BB-96?
Official CEC datasheet figures for RNG International Inc RSP360D-BB-96 (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 339.6 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.43 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.11 V / 12.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.289 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.81% (1.73 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many RNG International Inc RSP360D-BB-96 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many RNG International Inc RSP360D-BB-96 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 317 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 428 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 521 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This RNG International Inc Series?
Consolidated RNG International Inc wattage variants sharing the RNG International Inc RSP360D-BB-96 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| RNG International Inc RSP350D-BB-96 | 350.0 W | 329.9 W | 32.92 V | 27.83 V | 20.23% |
| RNG International Inc RSP355D-BB-96 | 355.0 W | 334.7 W | 33.29 V | 28.11 V | 20.52% |
| RNG International Inc RSP360D-BB-96 | 360.0 W | 339.6 W | 33.43 V | 28.11 V | 20.81% |
| RNG International Inc RSP365D-BB-96 | 365.0 W | 344.4 W | 33.15 V | 28.21 V | 21.1% |
| RNG International Inc RSP370D-BB-96 | 370.0 W | 349.2 W | 33.26 V | 28.37 V | 21.39% |
How Many RNG International Inc RSP360D-BB-96 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on RNG International Inc RSP360D-BB-96 (36.81 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.78 V | 15 panels | 566.7 V | 26 panels |
| -10 C (14 F) | 36.81 V | 16 panels | 589.0 V | 27 panels |
| 0 C (32 F) | 35.85 V | 16 panels | 573.6 V | 27 panels |
| 25 C (77 F STC) | 33.43 V | 17 panels | 568.3 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to RNG International Inc RSP360D-BB-96?
Competing CEC solar panels closest to RNG International Inc RSP360D-BB-96 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-360MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-360MS CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 40.4 V | 20.11% | 93.0% |
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| AXITEC AC-360MH/120V AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| AXITEC AC-360MH/120VB AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |
What Are the Design Limits and Best-Fit Uses for RNG International Inc RSP360D-BB-96?
Evaluate RNG International Inc RSP360D-BB-96 (360.0 W STC, 33.43 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), RNG International Inc RSP360D-BB-96 reaches 37.78 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 428 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (428 sq ft).
- 2026 tax credit baseline: cash residential installs of RNG International Inc RSP360D-BB-96 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
RNG International Inc RSP360D-BB-96 8 kW Residential Fit
Needs 23 modules (428 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 339.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for RNG International Inc RSP360D-BB-96 by RNG International Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for RNG International Inc RSP360D-BB-96?
Multiplying RNG International Inc RSP360D-BB-96's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can RNG International Inc RSP360D-BB-96 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 36.81 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap RNG International Inc RSP360D-BB-96 at 16 panels on 600 V.
Is RNG International Inc RSP360D-BB-96 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of RNG International Inc RSP360D-BB-96 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)