RNG International Inc RSP240D-BB-64 is a 240.0 W STC (226.3 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 20.51% efficiency, 22.28 V Voc at 25 C, and 24.53 V cold Voc at -10 C (24 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 226.3 W
- Voc @ 25C
- 22.28 V
- Efficiency
- 20.51%
How Does RNG International Inc RSP240D-BB-64 Compare Against Peer CEC Listings?
Solar engineering breakdown for RNG International Inc RSP240D-BB-64: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from RNG International Inc and peers, RNG International Inc RSP240D-BB-64 stands 170.0 W below the 410.0 W Mono-c-Si median and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Sizing 6 kW (25 panels) to 10 kW (42 panels) yields $1,502-$2,523/yr in baseline US bill offset. Lower 22.28 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.
Where Does RNG International Inc RSP240D-BB-64 Fall Across Listed CEC Models?
Distribution marker showing RNG International Inc RSP240D-BB-64 (240.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define RNG International Inc RSP240D-BB-64?
Dataset percentiles tracking RNG International Inc RSP240D-BB-64 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for RNG International Inc RSP240D-BB-64?
Benchmark highlights for RNG International Inc RSP240D-BB-64 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.51% Aperture Efficiency
Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
24 Panels Max @ -10 C (600 V)
Cold Voc reaches 24.53 V at -10 C (588.7 V string) and 25.18 V at -20 C (23 max).
34 Panels = 8,160 W STC
Occupies 39.8 m2 (428 sq ft) producing 7,694 W PTC; NEC 690.8 OCPD floor is 21.17 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.28 * (1 + (-0.289/100) * (-10 - 25)) = 24.53 V | OCPD = 1.56 * 13.57 = 21.17 A
Inputs from CEC Modules.csv for RNG International Inc RSP240D-BB-64: Voc=22.28 V, beta_Voc=-0.289%/C, Isc=13.57 A, STC=240.0 W, Area=1.17 m2.
Result: 24 panels max on 600 V (588.7 V); 34 panels for 8 kW (428 sq ft).
What Are the Published CEC Specifications for RNG International Inc RSP240D-BB-64?
Official CEC datasheet figures for RNG International Inc RSP240D-BB-64 (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 226.3 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.28 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 18.95 V / 12.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.289 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.51% (1.17 m2) | Array roof footprint density |
| Cell Count & Technology | 32 cells (Mono-c-Si) | Monofacial backsheet |
How Many RNG International Inc RSP240D-BB-64 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many RNG International Inc RSP240D-BB-64 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 315 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 428 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 529 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This RNG International Inc Series?
Consolidated RNG International Inc wattage variants sharing the RNG International Inc RSP240D-BB-64 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| RNG International Inc RSP235D-BB-64 | 235.0 W | 221.5 W | 22.1 V | 18.77 V | 20.09% |
| RNG International Inc RSP240D-BB-64 | 240.0 W | 226.3 W | 22.28 V | 18.95 V | 20.51% |
| RNG International Inc RSP245D-BB-64 | 245.0 W | 231.1 W | 22.61 V | 19.13 V | 20.94% |
How Many RNG International Inc RSP240D-BB-64 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on RNG International Inc RSP240D-BB-64 (24.53 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.18 V | 23 panels | 579.1 V | 39 panels |
| -10 C (14 F) | 24.53 V | 24 panels | 588.7 V | 40 panels |
| 0 C (32 F) | 23.89 V | 25 panels | 597.2 V | 41 panels |
| 25 C (77 F STC) | 22.28 V | 26 panels | 579.3 V | 44 panels |
Which Cross-Brand Solar Modules Compare Closest to RNG International Inc RSP240D-BB-64?
Competing CEC solar panels closest to RNG International Inc RSP240D-BB-64 in nameplate wattage and Voc, starting with GermanSolar USA Inc GSM10-Agri-225W-CG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GermanSolar USA Inc GSM10-Agri-225W-CG GermanSolar USA Inc |
225.0 W | -15.0 W | 20.5 V | 23.94% | 95.1% |
| GermanSolar USA Inc GSM10-Agri-215W-CG GermanSolar USA Inc |
215.0 W | -25.0 W | 20.44 V | 22.87% | 95.0% |
| Gintung Energy ASEC-235G6M69 Gintung Energy |
235.0 W | -5.0 W | 34.06 V | 16.04% | 88.1% |
| Gintung Energy GTEC-235G6M69 Gintung Energy |
235.0 W | -5.0 W | 34.06 V | 16.04% | 88.1% |
What Are the Design Limits and Best-Fit Uses for RNG International Inc RSP240D-BB-64?
Evaluate RNG International Inc RSP240D-BB-64 (240.0 W STC, 22.28 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), RNG International Inc RSP240D-BB-64 reaches 25.18 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 428 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (428 sq ft).
- 2026 tax credit baseline: cash residential installs of RNG International Inc RSP240D-BB-64 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
RNG International Inc RSP240D-BB-64 8 kW Residential Fit
Needs 34 modules (428 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare GermanSolar USA Inc GSM10-Agri-225W-CG.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for RNG International Inc RSP240D-BB-64 by RNG International Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for RNG International Inc RSP240D-BB-64?
Multiplying RNG International Inc RSP240D-BB-64's 13.57 A short-circuit current by 1.56 equals 21.17 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can RNG International Inc RSP240D-BB-64 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 24.53 V cold Voc at 14 F and handles 13.57 A Isc; string inverters cap RNG International Inc RSP240D-BB-64 at 24 panels on 600 V.
Is RNG International Inc RSP240D-BB-64 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of RNG International Inc RSP240D-BB-64 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)