RNG International Inc RSP240D-64 — CEC Solar Module Specifications

Manufacturer: RNG International Inc Registry: CEC Verified Engineering Specification

RNG International Inc RSP240D-64 is a 240.0 W STC (226.3 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 20.51% efficiency, 22.1 V Voc at 25 C, and 24.34 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
226.3 W
Voc @ 25C
22.1 V
Efficiency
20.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does RNG International Inc RSP240D-64 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for RNG International Inc RSP240D-64 (Mono-c-Si) residential solar systems.

RNG International Inc RSP240D-64 delivers 205.1 W/m2 (0.60 percentage points above 19.91% CEC median) and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (428 sq ft). At -4 F (-20 C), string voltage climbs to 24.97 V per unit, capping 600 V circuits at 24 panels. Compare specs directly with GermanSolar USA Inc GSM10-Agri-225W-CG (225.0 W).

Where Does RNG International Inc RSP240D-64 Fall Across Listed CEC Models?

Comparison of RNG International Inc RSP240D-64 (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where RNG International Inc RSP240D-64 (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRNG International : 240.0 W

What Dataset Percentiles Define RNG International Inc RSP240D-64?

Relative ranking of RNG International Inc RSP240D-64 across nameplate watts, 94.3% PTC thermal ratio, and module aperture efficiency.

RNG International Inc RSP240D-64 Engineering BenchmarksPercentile comparison of RNG International Inc RSP240D-64 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention94.3%Module Efficiency20.51%

What Do the Dataset Ranks Show for RNG International Inc RSP240D-64?

Summary of RNG International Inc RSP240D-64 output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.34 V at -10 C (584.2 V string) and 24.97 V at -20 C (24 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,694 W PTC; NEC 690.8 OCPD floor is 21.28 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.1 * (1 + (-0.289/100) * (-10 - 25)) = 24.34 V | OCPD = 1.56 * 13.64 = 21.28 A

Inputs from CEC Modules.csv for RNG International Inc RSP240D-64: Voc=22.1 V, beta_Voc=-0.289%/C, Isc=13.64 A, STC=240.0 W, Area=1.17 m2.

Result: 24 panels max on 600 V (584.2 V); 34 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for RNG International Inc RSP240D-64?

Complete CEC test sheet for RNG International Inc RSP240D-64 including Isc (13.64 A), Voc (22.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for RNG International Inc RSP240D-64.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 226.3 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 18.77 V / 12.79 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.289 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.51% (1.17 m2) Array roof footprint density
Cell Count & Technology 32 cells (Mono-c-Si) Monofacial backsheet

How Many RNG International Inc RSP240D-64 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using RNG International Inc RSP240D-64.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 315 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 428 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 529 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This RNG International Inc Series?

Related RNG International Inc power steps and black/silver trims consolidated into this RNG International Inc RSP240D-64 series guide.

Sibling CEC listings grouped into the RNG International Inc RSP240D-64 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
RNG International Inc RSP235D-64 235.0 W 221.5 W 21.87 V 18.51 V 20.09%
RNG International Inc RSP240D-64 240.0 W 226.3 W 22.1 V 18.77 V 20.51%
RNG International Inc RSP245D-64 245.0 W 231.1 W 22.38 V 18.95 V 20.94%

How Many RNG International Inc RSP240D-64 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for RNG International Inc RSP240D-64 (22.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=22.1V and beta_Voc=-0.289%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 24.97 V 24 panels 599.3 V 40 panels
-10 C (14 F) 24.34 V 24 panels 584.2 V 41 panels
0 C (32 F) 23.7 V 25 panels 592.5 V 42 panels
25 C (77 F STC) 22.1 V 27 panels 596.7 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to RNG International Inc RSP240D-64?

Four comparable CEC modules such as GermanSolar USA Inc GSM10-Agri-225W-CG (225.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GermanSolar USA Inc GSM10-Agri-225W-CG
GermanSolar USA Inc
225.0 W -15.0 W 20.5 V 23.94% 95.1%
GermanSolar USA Inc GSM10-Agri-215W-CG
GermanSolar USA Inc
215.0 W -25.0 W 20.44 V 22.87% 95.0%
Gintung Energy ASEC-235G6M69
Gintung Energy
235.0 W -5.0 W 34.06 V 16.04% 88.1%
Gintung Energy GTEC-235G6M69
Gintung Energy
235.0 W -5.0 W 34.06 V 16.04% 88.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for RNG International Inc RSP240D-64?

Evaluate RNG International Inc RSP240D-64 (240.0 W STC, 22.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), RNG International Inc RSP240D-64 reaches 24.97 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 428 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (428 sq ft).
  • 2026 tax credit baseline: cash residential installs of RNG International Inc RSP240D-64 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

RNG International Inc RSP240D-64 8 kW Residential Fit

Needs 34 modules (428 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 24 panels (-20 C), or compare GermanSolar USA Inc GSM10-Agri-225W-CG.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for RNG International Inc RSP240D-64 by RNG International Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many RNG International Inc RSP240D-64 panels fit on a 600 V winter solar string?

At -10 C (14 F), RNG International Inc RSP240D-64 cold Voc rises from 22.1 V to 24.34 V (beta_Voc -0.289%/C), capping a 600 V string at 24 panels (584.2 V).

How much roof area does an 8 kW array of RNG International Inc RSP240D-64 need?

An 8 kW DC system uses 34 RNG International Inc RSP240D-64 modules (8,160 W STC / 7,694 W PTC), covering roughly 428 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does RNG International Inc RSP240D-64 compare against GermanSolar USA Inc GSM10-Agri-225W-CG?

RNG International Inc RSP240D-64 outputs 240.0 W STC (22.1 V Voc, rank #20,160 of 21,677), while GermanSolar USA Inc GSM10-Agri-225W-CG delivers 225.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.