Skip to main content
WireAndSun
Calculators
CEC PV Module

Resun Solar Inc RS8I560M-DG — CEC Solar Module Specifications

Manufacturer: Resun Solar Inc Registry: CEC Verified Engineering Specification

Resun Solar Inc RS8I560M-DG is a 560.0 W STC (527.2 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.71% efficiency, 51.05 V Voc at 25 C, and 55.53 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
560.0 W
PTC Wattage
527.2 W
Voc @ 25C
51.05 V
Efficiency
21.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Resun Solar Inc RS8I560M-DG Compare Against Peer CEC Listings?

How Resun Solar Inc Resun Solar Inc RS8I560M-DG handles rooftop heat (527.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Resun Solar Inc RS8I560M-DG exhibits 13.99 A short-circuit current, requiring a 21.82 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,404 of 21,677 (150.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.7 m2 for an 8 kW system (18 panels for 10 kW). Higher 51.05 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Resun Solar Inc RS8I560M-DG Fall Across Listed CEC Models?

Where Resun Solar Inc RS8I560M-DG (560.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Resun Solar Inc RS8I560M-DG (560.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCResun Solar Inc RS: 560.0 W

What Dataset Percentiles Define Resun Solar Inc RS8I560M-DG?

Percentile placement of Resun Solar Inc RS8I560M-DG across power density (217.1 W/m2), thermal retention, and nameplate STC wattage.

Resun Solar Inc RS8I560M-DG Engineering BenchmarksPercentile comparison of Resun Solar Inc RS8I560M-DG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage560.0 WPTC/STC Retention94.1%Module Efficiency21.71%

What Do the Dataset Ranks Show for Resun Solar Inc RS8I560M-DG?

Four critical engineering numbers homeowners and solar installers check first when reviewing Resun Solar Inc RS8I560M-DG specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #2,404 / 21,677

Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,802

21.71% Aperture Efficiency

Power density 217.1 W/m2 (1.80 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.53 V at -10 C (555.3 V string) and 56.82 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,400 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,908 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.05 * (1 + (-0.251/100) * (-10 - 25)) = 55.53 V | OCPD = 1.56 * 13.99 = 21.82 A

Inputs from CEC Modules.csv for Resun Solar Inc RS8I560M-DG: Voc=51.05 V, beta_Voc=-0.251%/C, Isc=13.99 A, STC=560.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (555.3 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Resun Solar Inc RS8I560M-DG?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Resun Solar Inc RS8I560M-DG.

Official California Energy Commission (NREL SAM) test parameters for Resun Solar Inc RS8I560M-DG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 560.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 527.2 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.47 V / 13.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.251 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.71% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Resun Solar Inc RS8I560M-DG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Resun Solar Inc RS8I560M-DG (560.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.16 kW 305 sq ft $1,542 $2,607
8 kW Class 15 8.4 kW 417 sq ft $2,102 $3,555
10 kW Class 18 10.08 kW 500 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Resun Solar Inc Series?

All closely matched Resun Solar Inc wattages and cosmetic trims sharing the Resun Solar Inc RS8I560M-DG architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Resun Solar Inc RS8I560M-DG wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Resun Solar Inc RS8I550M-DG 550.0 W 517.5 W 50.75 V 42.17 V 21.32%
Resun Solar Inc RS8I555M-DG 555.0 W 522.3 W 50.9 V 42.34 V 21.51%
Resun Solar Inc RS8I560M-DG 560.0 W 527.2 W 51.05 V 42.47 V 21.71%
Resun Solar Inc RS8I565M-DG 565.0 W 532.0 W 51.2 V 42.62 V 21.9%
Resun Solar Inc RS8I570M-DG 570.0 W 536.8 W 51.35 V 42.77 V 22.09%

How Many Resun Solar Inc RS8I560M-DG Modules Fit in a Cold-Weather String?

Maximum series module counts for Resun Solar Inc RS8I560M-DG from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=51.05V and beta_Voc=-0.251%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.82 V 10 panels 568.2 V 17 panels
-10 C (14 F) 55.53 V 10 panels 555.3 V 18 panels
0 C (32 F) 54.25 V 11 panels 596.8 V 18 panels
25 C (77 F STC) 51.05 V 11 panels 561.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Resun Solar Inc RS8I560M-DG?

Alternative CEC solar modules from competing brands near Resun Solar Inc RS8I560M-DG (560.0 W), including EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E560HCBG144-T
EMMVEE Photovoltaic Power Private Limited
560.0 W Tie (0 W) 50.67 V 21.88% 93.4%
EMMVEE Photovoltaic Power Private Limited E560HCBT144-T
EMMVEE Photovoltaic Power Private Limited
560.0 W Tie (0 W) 50.67 V 21.88% 94.5%
Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560
Chint New Energy Technology Co Ltd
560.0 W Tie (0 W) 50.5 V 21.71% 94.6%
Boviet Solar Technology Co Ltd BVM7612M-560-H-HC-BF
Boviet Solar Technology Co Ltd
560.0 W Tie (0 W) 51.66 V 21.71% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Resun Solar Inc RS8I560M-DG?

Evaluate Resun Solar Inc RS8I560M-DG (560.0 W STC, 51.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Resun Solar Inc RS8I560M-DG reaches 56.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Resun Solar Inc RS8I560M-DG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Resun Solar Inc RS8I560M-DG 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 527.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Resun Solar Inc RS8I560M-DG by Resun Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Resun Solar Inc RS8I560M-DG PTC wattage (527.2 W) lower than STC (560.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 527.2 W PTC (94.1% retention) across Resun Solar Inc RS8I560M-DG's 2.58 m2 aperture.

Who should skip Resun Solar Inc RS8I560M-DG on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Resun Solar Inc RS8I560M-DG panels (417 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.

What is the 1,000 V commercial string limit for Resun Solar Inc RS8I560M-DG?

On 1,000 V commercial inverters at -10 C (55.53 V cold Voc), Resun Solar Inc RS8I560M-DG fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Resun Solar Inc RS8I560M-DG.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.