Renesola America JC295M-24/Abh is a 295.0 W STC (270.0 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.2% efficiency, 44.7 V Voc at 25 C, and 51.08 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 270.0 W
- Voc @ 25C
- 44.7 V
- Efficiency
- 15.2%
How Does Renesola America JC295M-24/Abh Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Renesola America JC295M-24/Abh (Multi-c-Si) residential solar systems.
Homeowners evaluating Renesola America JC295M-24/Abh need 21 panels for 6 kW or 28 panels (585 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft). Under NEC 690.7(A), beta_Voc (-0.408%/C) pushes open-circuit voltage to 51.08 V at 14 F and 52.91 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Renesola America JC295M-24/Abh Fall Across Listed CEC Models?
Comparison of Renesola America JC295M-24/Abh (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Renesola America JC295M-24/Abh?
Relative ranking of Renesola America JC295M-24/Abh across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Renesola America JC295M-24/Abh?
Summary of Renesola America JC295M-24/Abh output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.2% Aperture Efficiency
Power density 152.1 W/m2 (4.71 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.08 V at -10 C (561.9 V string) and 52.91 V at -20 C (11 max).
28 Panels = 8,260 W STC
Occupies 54.3 m2 (585 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.7 * (1 + (-0.408/100) * (-10 - 25)) = 51.08 V | OCPD = 1.56 * 8.62 = 13.45 A
Inputs from CEC Modules.csv for Renesola America JC295M-24/Abh: Voc=44.7 V, beta_Voc=-0.408%/C, Isc=8.62 A, STC=295.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (561.9 V); 28 panels for 8 kW (585 sq ft).
What Are the Published CEC Specifications for Renesola America JC295M-24/Abh?
Complete CEC test sheet for Renesola America JC295M-24/Abh including Isc (8.62 A), Voc (44.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 270.0 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 8.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.408 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.2% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Renesola America JC295M-24/Abh Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Renesola America JC295M-24/Abh.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 439 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 585 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 710 sq ft | $2,510 | $4,245 |
How Many Renesola America JC295M-24/Abh Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Renesola America JC295M-24/Abh (44.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.91 V | 11 panels | 582.0 V | 18 panels |
| -10 C (14 F) | 51.08 V | 11 panels | 561.9 V | 19 panels |
| 0 C (32 F) | 49.26 V | 12 panels | 591.1 V | 20 panels |
| 25 C (77 F STC) | 44.7 V | 13 panels | 581.1 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Renesola America JC295M-24/Abh?
Four comparable CEC modules such as BYD Company Limited BYD295P6K-36 (295.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| Chinaland Solar Energy HSE295-72M Chinaland Solar Energy |
295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Centrosolar America TP7S 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Renesola America JC295M-24/Abh?
Evaluate Renesola America JC295M-24/Abh (295.0 W STC, 44.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC295M-24/Abh reaches 52.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Renesola America JC295M-24/Abh carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Renesola America JC295M-24/Abh 8 kW Residential Fit
Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Renesola America JC295M-24/Abh by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Renesola America JC295M-24/Abh PTC wattage (270.0 W) lower than STC (295.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.0 W PTC (91.5% retention) across Renesola America JC295M-24/Abh's 1.94 m2 aperture.
Who should skip Renesola America JC295M-24/Abh on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Renesola America JC295M-24/Abh panels (585 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD295P6K-36.
What is the 1,000 V commercial string limit for Renesola America JC295M-24/Abh?
On 1,000 V commercial inverters at -10 C (51.08 V cold Voc), Renesola America JC295M-24/Abh fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Renesola America JC295M-24/Abh.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)