Skip to main content
WireAndSun
Calculators
CEC PV Module

Renesola America JC295M-24/Abh — CEC Solar Module Specifications

Manufacturer: Renesola America Registry: CEC Verified Engineering Specification

Renesola America JC295M-24/Abh is a 295.0 W STC (270.0 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.2% efficiency, 44.7 V Voc at 25 C, and 51.08 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
270.0 W
Voc @ 25C
44.7 V
Efficiency
15.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Renesola America JC295M-24/Abh Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Renesola America JC295M-24/Abh (Multi-c-Si) residential solar systems.

Homeowners evaluating Renesola America JC295M-24/Abh need 21 panels for 6 kW or 28 panels (585 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft). Under NEC 690.7(A), beta_Voc (-0.408%/C) pushes open-circuit voltage to 51.08 V at 14 F and 52.91 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Renesola America JC295M-24/Abh Fall Across Listed CEC Models?

Comparison of Renesola America JC295M-24/Abh (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Renesola America JC295M-24/Abh (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRenesola America J: 295.0 W

What Dataset Percentiles Define Renesola America JC295M-24/Abh?

Relative ranking of Renesola America JC295M-24/Abh across nameplate watts, 91.5% PTC thermal ratio, and module aperture efficiency.

Renesola America JC295M-24/Abh Engineering BenchmarksPercentile comparison of Renesola America JC295M-24/Abh wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention91.5%Module Efficiency15.2%

What Do the Dataset Ranks Show for Renesola America JC295M-24/Abh?

Summary of Renesola America JC295M-24/Abh output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,427

15.2% Aperture Efficiency

Power density 152.1 W/m2 (4.71 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.08 V at -10 C (561.9 V string) and 52.91 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.7 * (1 + (-0.408/100) * (-10 - 25)) = 51.08 V | OCPD = 1.56 * 8.62 = 13.45 A

Inputs from CEC Modules.csv for Renesola America JC295M-24/Abh: Voc=44.7 V, beta_Voc=-0.408%/C, Isc=8.62 A, STC=295.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (561.9 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for Renesola America JC295M-24/Abh?

Complete CEC test sheet for Renesola America JC295M-24/Abh including Isc (8.62 A), Voc (44.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Renesola America JC295M-24/Abh.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 270.0 W (91.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.3 V / 8.13 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.408 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.2% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Renesola America JC295M-24/Abh Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Renesola America JC295M-24/Abh.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 439 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 585 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 710 sq ft $2,510 $4,245

How Many Renesola America JC295M-24/Abh Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Renesola America JC295M-24/Abh (44.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.7V and beta_Voc=-0.408%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.91 V 11 panels 582.0 V 18 panels
-10 C (14 F) 51.08 V 11 panels 561.9 V 19 panels
0 C (32 F) 49.26 V 12 panels 591.1 V 20 panels
25 C (77 F STC) 44.7 V 13 panels 581.1 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Renesola America JC295M-24/Abh?

Four comparable CEC modules such as BYD Company Limited BYD295P6K-36 (295.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W Tie (0 W) 44.9 V 15.21% 91.5%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W Tie (0 W) 44.4 V 15.28% 90.2%
Centrosolar America TP7 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
Centrosolar America TP7S 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Renesola America JC295M-24/Abh?

Evaluate Renesola America JC295M-24/Abh (295.0 W STC, 44.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC295M-24/Abh reaches 52.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of Renesola America JC295M-24/Abh carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Renesola America JC295M-24/Abh 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Renesola America JC295M-24/Abh by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Renesola America JC295M-24/Abh PTC wattage (270.0 W) lower than STC (295.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.0 W PTC (91.5% retention) across Renesola America JC295M-24/Abh's 1.94 m2 aperture.

Who should skip Renesola America JC295M-24/Abh on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Renesola America JC295M-24/Abh panels (585 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD295P6K-36.

What is the 1,000 V commercial string limit for Renesola America JC295M-24/Abh?

On 1,000 V commercial inverters at -10 C (51.08 V cold Voc), Renesola America JC295M-24/Abh fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Renesola America JC295M-24/Abh.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.