Regitec Solar BV RMH72/560S3 — CEC Solar Module Specifications

Manufacturer: Regitec Solar BV Registry: CEC Verified Engineering Specification

Regitec Solar BV RMH72/560S3 is a 545.0 W STC (511.4 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.12% efficiency, 50.67 V Voc at 25 C, and 55.05 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
545.0 W
PTC Wattage
511.4 W
Voc @ 25C
50.67 V
Efficiency
21.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Regitec Solar BV RMH72/560S3 Compare Against Peer CEC Listings?

How Regitec Solar BV Regitec Solar BV RMH72/560S3 handles rooftop heat (511.4 W PTC), 8 kW sizing, and cold winter string voltage.

Regitec Solar BV builds the Regitec Solar BV RMH72/560S3 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). Compared against Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 (545.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 50.67 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 22.04 A overcurrent floor served by a 25 A breaker.

Where Does Regitec Solar BV RMH72/560S3 Fall Across Listed CEC Models?

Where Regitec Solar BV RMH72/560S3 (545.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Regitec Solar BV RMH72/560S3 (545.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRegitec Solar BV R: 545.0 W

What Dataset Percentiles Define Regitec Solar BV RMH72/560S3?

Percentile placement of Regitec Solar BV RMH72/560S3 across power density (211.2 W/m2), thermal retention, and nameplate STC wattage.

Regitec Solar BV RMH72/560S3 Engineering BenchmarksPercentile comparison of Regitec Solar BV RMH72/560S3 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage545.0 WPTC/STC Retention93.8%Module Efficiency21.12%

What Do the Dataset Ranks Show for Regitec Solar BV RMH72/560S3?

Four critical engineering numbers homeowners and solar installers check first when reviewing Regitec Solar BV RMH72/560S3 specifications.

Rank #2,998 / 21,677

Top 15.1% STC Output

545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.05 V at -10 C (550.5 V string) and 56.3 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,175 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,671 W PTC; NEC 690.8 OCPD floor is 22.04 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.67 * (1 + (-0.247/100) * (-10 - 25)) = 55.05 V | OCPD = 1.56 * 14.13 = 22.04 A

Inputs from CEC Modules.csv for Regitec Solar BV RMH72/560S3: Voc=50.67 V, beta_Voc=-0.247%/C, Isc=14.13 A, STC=545.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (550.5 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Regitec Solar BV RMH72/560S3?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Regitec Solar BV RMH72/560S3.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMH72/560S3.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 545.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 511.4 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.67 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.95 V / 13.35 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.12% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Regitec Solar BV RMH72/560S3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Regitec Solar BV RMH72/560S3 (545.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.54 kW 333 sq ft $1,637 $2,768
8 kW Class 15 8.18 kW 417 sq ft $2,047 $3,462
10 kW Class 19 10.36 kW 528 sq ft $2,593 $4,385

How Many Regitec Solar BV RMH72/560S3 Modules Fit in a Cold-Weather String?

Maximum series module counts for Regitec Solar BV RMH72/560S3 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.67V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.3 V 10 panels 563.0 V 17 panels
-10 C (14 F) 55.05 V 10 panels 550.5 V 18 panels
0 C (32 F) 53.8 V 11 panels 591.8 V 18 panels
25 C (77 F STC) 50.67 V 11 panels 557.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH72/560S3?

Alternative CEC solar modules from competing brands near Regitec Solar BV RMH72/560S3 (545.0 W), including Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-545
Jiangsu Runergy New Energy Technology Co Ltd
545.0 W Tie (0 W) 50.07 V 21.12% 93.8%
Exiom Solution S A EX550-144MH
Exiom Solution S A
545.0 W Tie (0 W) 49.8 V 21.46% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH72/560S3?

Evaluate Regitec Solar BV RMH72/560S3 (545.0 W STC, 50.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH72/560S3 reaches 56.3 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH72/560S3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Regitec Solar BV RMH72/560S3 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 511.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMH72/560S3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Regitec Solar BV RMH72/560S3?

Multiplying Regitec Solar BV RMH72/560S3's 14.13 A short-circuit current by 1.56 equals 22.04 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Regitec Solar BV RMH72/560S3 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.05 V cold Voc at 14 F and handles 14.13 A Isc; string inverters cap Regitec Solar BV RMH72/560S3 at 10 panels on 600 V.

Is Regitec Solar BV RMH72/560S3 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Regitec Solar BV RMH72/560S3 rely on utility bill offset (~$2,047/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.