Regitec Solar BV RMH72/555S2 is a 555.0 W STC (523.2 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.51% efficiency, 50.32 V Voc at 25 C, and 54.74 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 555.0 W
- PTC Wattage
- 523.2 W
- Voc @ 25C
- 50.32 V
- Efficiency
- 21.51%
How Does Regitec Solar BV RMH72/555S2 Compare Against Peer CEC Listings?
Engineering position of Regitec Solar BV RMH72/555S2 (555.0 W STC) vs. ASTORIOS Holding Inc ASTR144BDG-555W-US across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Regitec Solar BV RMH72/555S2 pairs strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677) with 50.32 V nominal Voc. An 8 kW residential build (8,325 W DC, 7,848 W PTC) saves ~$2,082/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ASTORIOS Holding Inc ASTR144BDG-555W-US offers a 555.0 W alternative.
Where Does Regitec Solar BV RMH72/555S2 Fall Across Listed CEC Models?
Plots Regitec Solar BV RMH72/555S2 at 555.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Regitec Solar BV RMH72/555S2?
Benchmarks Regitec Solar BV RMH72/555S2 on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Regitec Solar BV RMH72/555S2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Regitec Solar BV RMH72/555S2 by Regitec Solar BV.
Top 12.6% STC Output
555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.51% Aperture Efficiency
Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.74 V at -10 C (547.4 V string) and 56.0 V at -20 C (10 max).
15 Panels = 8,325 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,848 W PTC; NEC 690.8 OCPD floor is 21.93 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.32 * (1 + (-0.251/100) * (-10 - 25)) = 54.74 V | OCPD = 1.56 * 14.06 = 21.93 A
Inputs from CEC Modules.csv for Regitec Solar BV RMH72/555S2: Voc=50.32 V, beta_Voc=-0.251%/C, Isc=14.06 A, STC=555.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (547.4 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMH72/555S2?
Laboratory test ratings recorded for Regitec Solar BV RMH72/555S2 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 523.2 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.64 V / 13.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.51% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Regitec Solar BV RMH72/555S2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for Regitec Solar BV RMH72/555S2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.11 kW | 305 sq ft | $1,529 | $2,586 |
| 8 kW Class | 15 | 8.32 kW | 417 sq ft | $2,082 | $3,521 |
| 10 kW Class | 19 | 10.54 kW | 528 sq ft | $2,638 | $4,461 |
Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?
Sibling wattage bins and frame colors grouped with Regitec Solar BV RMH72/555S2 under Regitec Solar BV to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Regitec Solar BV RMH72/550S2 | 550.0 W | 518.4 W | 50.18 V | 41.48 V | 21.32% |
| Regitec Solar BV RMH72/555S2 | 555.0 W | 523.2 W | 50.32 V | 41.64 V | 21.51% |
| Regitec Solar BV RMH72/560S2 | 560.0 W | 528.0 W | 50.67 V | 41.96 V | 21.71% |
How Many Regitec Solar BV RMH72/555S2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Regitec Solar BV RMH72/555S2 (beta_Voc -0.251%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.0 V | 10 panels | 560.0 V | 17 panels |
| -10 C (14 F) | 54.74 V | 10 panels | 547.4 V | 18 panels |
| 0 C (32 F) | 53.48 V | 11 panels | 588.3 V | 18 panels |
| 25 C (77 F STC) | 50.32 V | 11 panels | 553.5 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH72/555S2?
Closest cross-brand CEC competitors to Regitec Solar BV RMH72/555S2 matched near 555.0 W STC and 50.32 V Voc, led by ASTORIOS Holding Inc ASTR144BDG-555W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR144BDG-555W-US ASTORIOS Holding Inc |
555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.7% |
| AXITEC AC-555MBT/144US AXITEC |
555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |
| Energy America LLC EA-ZLK7-SHDB144-555/M Energy America LLC |
555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555 Chint New Energy Technology Co Ltd |
555.0 W | Tie (0 W) | 50.5 V | 22.38% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH72/555S2?
Evaluate Regitec Solar BV RMH72/555S2 (555.0 W STC, 50.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH72/555S2 reaches 56.0 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH72/555S2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMH72/555S2 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare ASTORIOS Holding Inc ASTR144BDG-555W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 523.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMH72/555S2 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Regitec Solar BV RMH72/555S2?
Multiplying Regitec Solar BV RMH72/555S2's 14.06 A short-circuit current by 1.56 equals 21.93 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Regitec Solar BV RMH72/555S2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.74 V cold Voc at 14 F and handles 14.06 A Isc; string inverters cap Regitec Solar BV RMH72/555S2 at 10 panels on 600 V.
Is Regitec Solar BV RMH72/555S2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Regitec Solar BV RMH72/555S2 rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)