Skip to main content
WireAndSun
Calculators
CEC PV Module

Regitec Solar BV RMH72/550S3 — CEC Solar Module Specifications

Manufacturer: Regitec Solar BV Registry: CEC Verified Engineering Specification

Regitec Solar BV RMH72/550S3 is a 555.0 W STC (521.1 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.51% efficiency, 50.18 V Voc at 25 C, and 54.52 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
555.0 W
PTC Wattage
521.1 W
Voc @ 25C
50.18 V
Efficiency
21.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Regitec Solar BV RMH72/550S3 Compare Against Peer CEC Listings?

Engineering position of Regitec Solar BV RMH72/550S3 (555.0 W STC) vs. Bluesun Solar CoLtd BSM555M10-72HPH across 5,889 CEC Mono-c-Si solar modules.

Ranking #2,550 across 21,677 CEC solar panels (top 12.6%; higher than 87.4% of peers), Regitec Solar BV RMH72/550S3 operates as a large-format commercial and ground-mount module sitting 145.0 W above the 410.0 W Mono-c-Si median. Higher 50.18 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), 15 panels occupy 417 sq ft and offset roughly $2,082/yr at average US rates (or $3,521/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Regitec Solar BV RMH72/550S3 Fall Across Listed CEC Models?

Plots Regitec Solar BV RMH72/550S3 at 555.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Regitec Solar BV RMH72/550S3 (555.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRegitec Solar BV R: 555.0 W

What Dataset Percentiles Define Regitec Solar BV RMH72/550S3?

Benchmarks Regitec Solar BV RMH72/550S3 on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.

Regitec Solar BV RMH72/550S3 Engineering BenchmarksPercentile comparison of Regitec Solar BV RMH72/550S3 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage555.0 WPTC/STC Retention93.9%Module Efficiency21.51%

What Do the Dataset Ranks Show for Regitec Solar BV RMH72/550S3?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Regitec Solar BV RMH72/550S3 by Regitec Solar BV.

Rank #2,550 / 21,677

Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,356

21.51% Aperture Efficiency

Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.52 V at -10 C (599.7 V string) and 55.76 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,325 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,816 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.18 * (1 + (-0.247/100) * (-10 - 25)) = 54.52 V | OCPD = 1.56 * 13.98 = 21.81 A

Inputs from CEC Modules.csv for Regitec Solar BV RMH72/550S3: Voc=50.18 V, beta_Voc=-0.247%/C, Isc=13.98 A, STC=555.0 W, Area=2.58 m2.

Result: 11 panels max on 600 V (599.7 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Regitec Solar BV RMH72/550S3?

Laboratory test ratings recorded for Regitec Solar BV RMH72/550S3 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMH72/550S3.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 555.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 521.1 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.47 V / 13.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.51% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Regitec Solar BV RMH72/550S3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for Regitec Solar BV RMH72/550S3.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.11 kW 305 sq ft $1,529 $2,586
8 kW Class 15 8.32 kW 417 sq ft $2,082 $3,521
10 kW Class 19 10.54 kW 528 sq ft $2,638 $4,461

Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?

Sibling wattage bins and frame colors grouped with Regitec Solar BV RMH72/550S3 under Regitec Solar BV to prevent duplicate spec pages.

Sibling CEC listings grouped into the Regitec Solar BV RMH72/550S3 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Regitec Solar BV RMH72/555S3 550.0 W 516.3 W 50.32 V 41.62 V 21.32%
Regitec Solar BV RMH72/550S3 555.0 W 521.1 W 50.18 V 41.47 V 21.51%
Regitec Solar BV RMH72/545S3 560.0 W 525.9 W 50.04 V 41.32 V 21.71%

How Many Regitec Solar BV RMH72/550S3 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Regitec Solar BV RMH72/550S3 (beta_Voc -0.247%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=50.18V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.76 V 10 panels 557.6 V 17 panels
-10 C (14 F) 54.52 V 11 panels 599.7 V 18 panels
0 C (32 F) 53.28 V 11 panels 586.1 V 18 panels
25 C (77 F STC) 50.18 V 11 panels 552.0 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH72/550S3?

Closest cross-brand CEC competitors to Regitec Solar BV RMH72/550S3 matched near 555.0 W STC and 50.18 V Voc, led by Bluesun Solar CoLtd BSM555M10-72HPH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar CoLtd BSM555M10-72HPH
Bluesun Solar CoLtd
555.0 W Tie (0 W) 50.08 V 21.42% 93.3%
G-Star Pte Ltd GSD7G72M-555BT
G-Star Pte Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 94.3%
G-Star Pte Ltd GSD7G72M-555WT
G-Star Pte Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 94.3%
AXITEC AC-555MH/144V
AXITEC
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH72/550S3?

Evaluate Regitec Solar BV RMH72/550S3 (555.0 W STC, 50.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH72/550S3 reaches 55.76 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH72/550S3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Regitec Solar BV RMH72/550S3 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM555M10-72HPH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 521.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMH72/550S3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

How many Regitec Solar BV RMH72/550S3 panels fit on a 600 V winter solar string?

At -10 C (14 F), Regitec Solar BV RMH72/550S3 cold Voc rises from 50.18 V to 54.52 V (beta_Voc -0.247%/C), capping a 600 V string at 11 panels (599.7 V).

How much roof area does an 8 kW array of Regitec Solar BV RMH72/550S3 need?

An 8 kW DC system uses 15 Regitec Solar BV RMH72/550S3 modules (8,325 W STC / 7,816 W PTC), covering roughly 417 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

How does Regitec Solar BV RMH72/550S3 compare against Bluesun Solar CoLtd BSM555M10-72HPH?

Regitec Solar BV RMH72/550S3 outputs 555.0 W STC (50.18 V Voc, rank #2,550 of 21,677), while Bluesun Solar CoLtd BSM555M10-72HPH delivers 555.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.