Regitec Solar BV RMH72/550S3 is a 555.0 W STC (521.1 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.51% efficiency, 50.18 V Voc at 25 C, and 54.52 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 555.0 W
- PTC Wattage
- 521.1 W
- Voc @ 25C
- 50.18 V
- Efficiency
- 21.51%
How Does Regitec Solar BV RMH72/550S3 Compare Against Peer CEC Listings?
Engineering position of Regitec Solar BV RMH72/550S3 (555.0 W STC) vs. Bluesun Solar CoLtd BSM555M10-72HPH across 5,889 CEC Mono-c-Si solar modules.
Ranking #2,550 across 21,677 CEC solar panels (top 12.6%; higher than 87.4% of peers), Regitec Solar BV RMH72/550S3 operates as a large-format commercial and ground-mount module sitting 145.0 W above the 410.0 W Mono-c-Si median. Higher 50.18 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), 15 panels occupy 417 sq ft and offset roughly $2,082/yr at average US rates (or $3,521/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Regitec Solar BV RMH72/550S3 Fall Across Listed CEC Models?
Plots Regitec Solar BV RMH72/550S3 at 555.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Regitec Solar BV RMH72/550S3?
Benchmarks Regitec Solar BV RMH72/550S3 on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Regitec Solar BV RMH72/550S3?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Regitec Solar BV RMH72/550S3 by Regitec Solar BV.
Top 12.6% STC Output
555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.51% Aperture Efficiency
Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.52 V at -10 C (599.7 V string) and 55.76 V at -20 C (10 max).
15 Panels = 8,325 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,816 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.18 * (1 + (-0.247/100) * (-10 - 25)) = 54.52 V | OCPD = 1.56 * 13.98 = 21.81 A
Inputs from CEC Modules.csv for Regitec Solar BV RMH72/550S3: Voc=50.18 V, beta_Voc=-0.247%/C, Isc=13.98 A, STC=555.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (599.7 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMH72/550S3?
Laboratory test ratings recorded for Regitec Solar BV RMH72/550S3 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 521.1 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.47 V / 13.26 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.51% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Regitec Solar BV RMH72/550S3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for Regitec Solar BV RMH72/550S3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.11 kW | 305 sq ft | $1,529 | $2,586 |
| 8 kW Class | 15 | 8.32 kW | 417 sq ft | $2,082 | $3,521 |
| 10 kW Class | 19 | 10.54 kW | 528 sq ft | $2,638 | $4,461 |
Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?
Sibling wattage bins and frame colors grouped with Regitec Solar BV RMH72/550S3 under Regitec Solar BV to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Regitec Solar BV RMH72/555S3 | 550.0 W | 516.3 W | 50.32 V | 41.62 V | 21.32% |
| Regitec Solar BV RMH72/550S3 | 555.0 W | 521.1 W | 50.18 V | 41.47 V | 21.51% |
| Regitec Solar BV RMH72/545S3 | 560.0 W | 525.9 W | 50.04 V | 41.32 V | 21.71% |
How Many Regitec Solar BV RMH72/550S3 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Regitec Solar BV RMH72/550S3 (beta_Voc -0.247%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.76 V | 10 panels | 557.6 V | 17 panels |
| -10 C (14 F) | 54.52 V | 11 panels | 599.7 V | 18 panels |
| 0 C (32 F) | 53.28 V | 11 panels | 586.1 V | 18 panels |
| 25 C (77 F STC) | 50.18 V | 11 panels | 552.0 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH72/550S3?
Closest cross-brand CEC competitors to Regitec Solar BV RMH72/550S3 matched near 555.0 W STC and 50.18 V Voc, led by Bluesun Solar CoLtd BSM555M10-72HPH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM555M10-72HPH Bluesun Solar CoLtd |
555.0 W | Tie (0 W) | 50.08 V | 21.42% | 93.3% |
| G-Star Pte Ltd GSD7G72M-555BT G-Star Pte Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| G-Star Pte Ltd GSD7G72M-555WT G-Star Pte Ltd |
555.0 W | Tie (0 W) | 50.08 V | 21.68% | 94.3% |
| AXITEC AC-555MH/144V AXITEC |
555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH72/550S3?
Evaluate Regitec Solar BV RMH72/550S3 (555.0 W STC, 50.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH72/550S3 reaches 55.76 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH72/550S3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMH72/550S3 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM555M10-72HPH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 521.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMH72/550S3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
How many Regitec Solar BV RMH72/550S3 panels fit on a 600 V winter solar string?
At -10 C (14 F), Regitec Solar BV RMH72/550S3 cold Voc rises from 50.18 V to 54.52 V (beta_Voc -0.247%/C), capping a 600 V string at 11 panels (599.7 V).
How much roof area does an 8 kW array of Regitec Solar BV RMH72/550S3 need?
An 8 kW DC system uses 15 Regitec Solar BV RMH72/550S3 modules (8,325 W STC / 7,816 W PTC), covering roughly 417 sq ft and saving ~$2,082/yr at 18.54 c/kWh.
How does Regitec Solar BV RMH72/550S3 compare against Bluesun Solar CoLtd BSM555M10-72HPH?
Regitec Solar BV RMH72/550S3 outputs 555.0 W STC (50.18 V Voc, rank #2,550 of 21,677), while Bluesun Solar CoLtd BSM555M10-72HPH delivers 555.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)