Regitec Solar BV RMH54/420B2 is a 420.0 W STC (396.0 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.54% efficiency, 38.46 V Voc at 25 C, and 41.84 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 396.0 W
- Voc @ 25C
- 38.46 V
- Efficiency
- 21.54%
How Does Regitec Solar BV RMH54/420B2 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Regitec Solar BV RMH54/420B2 (Mono-c-Si) residential solar systems.
Homeowners evaluating Regitec Solar BV RMH54/420B2 need 15 panels for 6 kW or 20 panels (420 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.251%/C) pushes open-circuit voltage to 41.84 V at 14 F and 42.8 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Regitec Solar BV RMH54/420B2 Fall Across Listed CEC Models?
Comparison of Regitec Solar BV RMH54/420B2 (420.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Regitec Solar BV RMH54/420B2?
Relative ranking of Regitec Solar BV RMH54/420B2 across nameplate watts, 94.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Regitec Solar BV RMH54/420B2?
Summary of Regitec Solar BV RMH54/420B2 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.54% Aperture Efficiency
Power density 215.4 W/m2 (1.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.84 V at -10 C (585.8 V string) and 42.8 V at -20 C (14 max).
20 Panels = 8,400 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,920 W PTC; NEC 690.8 OCPD floor is 21.98 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.46 * (1 + (-0.251/100) * (-10 - 25)) = 41.84 V | OCPD = 1.56 * 14.09 = 21.98 A
Inputs from CEC Modules.csv for Regitec Solar BV RMH54/420B2: Voc=38.46 V, beta_Voc=-0.251%/C, Isc=14.09 A, STC=420.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (585.8 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMH54/420B2?
Complete CEC test sheet for Regitec Solar BV RMH54/420B2 including Isc (14.09 A), Voc (38.46 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 396.0 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.97 V / 13.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.54% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Regitec Solar BV RMH54/420B2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Regitec Solar BV RMH54/420B2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 315 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 420 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 504 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?
Related Regitec Solar BV power steps and black/silver trims consolidated into this Regitec Solar BV RMH54/420B2 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Regitec Solar BV RMH54/415B2 | 415.0 W | 391.1 W | 38.33 V | 31.79 V | 21.28% |
| Regitec Solar BV RMH54/420B2 | 420.0 W | 396.0 W | 38.46 V | 31.97 V | 21.54% |
How Many Regitec Solar BV RMH54/420B2 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Regitec Solar BV RMH54/420B2 (38.46 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.8 V | 14 panels | 599.2 V | 23 panels |
| -10 C (14 F) | 41.84 V | 14 panels | 585.8 V | 23 panels |
| 0 C (32 F) | 40.87 V | 14 panels | 572.2 V | 24 panels |
| 25 C (77 F STC) | 38.46 V | 15 panels | 576.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH54/420B2?
Four comparable CEC modules such as Aptos Solar Technology LLC DNA-108-BFN10-420W-DG (420.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-BFN10-420W-DG Aptos Solar Technology LLC |
420.0 W | Tie (0 W) | 37.6 V | 21.65% | 94.9% |
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF Boviet Solar Technology Co Ltd |
415.0 W | -5.0 W | 38.47 V | 19.21% | 94.7% |
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF-DG Boviet Solar Technology Co Ltd |
415.0 W | -5.0 W | 38.47 V | 19.21% | 94.7% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | -10.0 W | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH54/420B2?
Evaluate Regitec Solar BV RMH54/420B2 (420.0 W STC, 38.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH54/420B2 reaches 42.8 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH54/420B2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMH54/420B2 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BFN10-420W-DG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 396.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMH54/420B2 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Regitec Solar BV RMH54/420B2 PTC wattage (396.0 W) lower than STC (420.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 396.0 W PTC (94.3% retention) across Regitec Solar BV RMH54/420B2's 1.95 m2 aperture.
Who should skip Regitec Solar BV RMH54/420B2 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Regitec Solar BV RMH54/420B2 panels (420 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-BFN10-420W-DG.
What is the 1,000 V commercial string limit for Regitec Solar BV RMH54/420B2?
On 1,000 V commercial inverters at -10 C (41.84 V cold Voc), Regitec Solar BV RMH54/420B2 fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)