Regitec Solar BV RMH54/415AB3 is a 435.0 W STC (408.8 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.31% efficiency, 37.92 V Voc at 25 C, and 41.2 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 408.8 W
- Voc @ 25C
- 37.92 V
- Efficiency
- 22.31%
How Does Regitec Solar BV RMH54/415AB3 Compare Against Peer CEC Listings?
Engineering position of Regitec Solar BV RMH54/415AB3 (435.0 W STC) vs. AXITEC AC-435TGB/108BB across 5,889 CEC Mono-c-Si solar modules.
Ranking #6,850 across 21,677 CEC solar panels (top 33.5%; higher than 66.5% of peers), Regitec Solar BV RMH54/415AB3 operates as a modern high-density residential and light-commercial module sitting 25.0 W above the 410.0 W Mono-c-Si median. Lower 37.92 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), 19 panels occupy 399 sq ft and offset roughly $2,070/yr at average US rates (or $3,500/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Regitec Solar BV RMH54/415AB3 Fall Across Listed CEC Models?
Plots Regitec Solar BV RMH54/415AB3 at 435.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Regitec Solar BV RMH54/415AB3?
Benchmarks Regitec Solar BV RMH54/415AB3 on STC wattage, thermal PTC/STC retention, and 22.31 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Regitec Solar BV RMH54/415AB3?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Regitec Solar BV RMH54/415AB3 by Regitec Solar BV.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.31% Aperture Efficiency
Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.2 V at -10 C (576.8 V string) and 42.13 V at -20 C (14 max).
19 Panels = 8,265 W STC
Occupies 37.0 m2 (399 sq ft) producing 7,767 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.92 * (1 + (-0.247/100) * (-10 - 25)) = 41.2 V | OCPD = 1.56 * 13.99 = 21.82 A
Inputs from CEC Modules.csv for Regitec Solar BV RMH54/415AB3: Voc=37.92 V, beta_Voc=-0.247%/C, Isc=13.99 A, STC=435.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (576.8 V); 19 panels for 8 kW (399 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMH54/415AB3?
Laboratory test ratings recorded for Regitec Solar BV RMH54/415AB3 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 408.8 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.32 V / 13.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.31% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Regitec Solar BV RMH54/415AB3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (399 sq ft at 8 kW), and estimated Year-1 electric bill offset for Regitec Solar BV RMH54/415AB3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 294 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 399 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 483 sq ft | $2,505 | $4,236 |
How Many Regitec Solar BV RMH54/415AB3 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Regitec Solar BV RMH54/415AB3 (beta_Voc -0.247%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.13 V | 14 panels | 589.8 V | 23 panels |
| -10 C (14 F) | 41.2 V | 14 panels | 576.8 V | 24 panels |
| 0 C (32 F) | 40.26 V | 14 panels | 563.6 V | 24 panels |
| 25 C (77 F STC) | 37.92 V | 15 panels | 568.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMH54/415AB3?
Closest cross-brand CEC competitors to Regitec Solar BV RMH54/415AB3 matched near 435.0 W STC and 37.92 V Voc, led by AXITEC AC-435TGB/108BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-435TGB/108BB AXITEC |
435.0 W | Tie (0 W) | 38.43 V | 22.89% | 95.0% |
| Auxin Solar AXN10M435B Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| Auxin Solar AXN10M435W Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 Elin Energy (Sirius PV) |
435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMH54/415AB3?
Evaluate Regitec Solar BV RMH54/415AB3 (435.0 W STC, 37.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMH54/415AB3 reaches 42.13 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMH54/415AB3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMH54/415AB3 8 kW Residential Fit
Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-435TGB/108BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMH54/415AB3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
How many Regitec Solar BV RMH54/415AB3 panels fit on a 600 V winter solar string?
At -10 C (14 F), Regitec Solar BV RMH54/415AB3 cold Voc rises from 37.92 V to 41.2 V (beta_Voc -0.247%/C), capping a 600 V string at 14 panels (576.8 V).
How much roof area does an 8 kW array of Regitec Solar BV RMH54/415AB3 need?
An 8 kW DC system uses 19 Regitec Solar BV RMH54/415AB3 modules (8,265 W STC / 7,767 W PTC), covering roughly 399 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does Regitec Solar BV RMH54/415AB3 compare against AXITEC AC-435TGB/108BB?
Regitec Solar BV RMH54/415AB3 outputs 435.0 W STC (37.92 V Voc, rank #6,850 of 21,677), while AXITEC AC-435TGB/108BB delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)