Manufacturer: RECOM SILLIA Registry: CEC Verified Engineering Specification

RECOM SILLIA RCM-285-6PB is a 285.0 W STC (251.1 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.59% efficiency, 43.0 V Voc at 25 C, and 48.4 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
251.1 W
Voc @ 25C
43.0 V
Efficiency
17.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does RECOM SILLIA RCM-285-6PB Compare Against Peer CEC Listings?

How RECOM SILLIA RECOM SILLIA RCM-285-6PB handles rooftop heat (251.1 W PTC), 8 kW sizing, and cold winter string voltage.

RECOM SILLIA builds the RECOM SILLIA RCM-285-6PB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 175.9 W/m2 (2.32 percentage points below 19.91% CEC median). Compared against Anhui Rinengzhongtian Semiconductor Development QJP285-72 (285.0 W), this model holds typical 88.1% PTC-to-STC thermal output (251.1 W real-world rating). Mid-range 43.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.77 A overcurrent floor served by a 15 A breaker.

Where Does RECOM SILLIA RCM-285-6PB Fall Across Listed CEC Models?

Where RECOM SILLIA RCM-285-6PB (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where RECOM SILLIA RCM-285-6PB (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRECOM SILLIA RCM-2: 285.0 W

What Dataset Percentiles Define RECOM SILLIA RCM-285-6PB?

Percentile placement of RECOM SILLIA RCM-285-6PB across power density (175.9 W/m2), thermal retention, and nameplate STC wattage.

RECOM SILLIA RCM-285-6PB Engineering BenchmarksPercentile comparison of RECOM SILLIA RCM-285-6PB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention88.1%Module Efficiency17.59%

What Do the Dataset Ranks Show for RECOM SILLIA RCM-285-6PB?

Four critical engineering numbers homeowners and solar installers check first when reviewing RECOM SILLIA RCM-285-6PB specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,646

17.59% Aperture Efficiency

Power density 175.9 W/m2 (2.32 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.4 V at -10 C (580.8 V string) and 49.95 V at -20 C (12 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,282 W PTC; NEC 690.8 OCPD floor is 13.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.0 * (1 + (-0.359/100) * (-10 - 25)) = 48.4 V | OCPD = 1.56 * 8.83 = 13.77 A

Inputs from CEC Modules.csv for RECOM SILLIA RCM-285-6PB: Voc=43.0 V, beta_Voc=-0.359%/C, Isc=8.83 A, STC=285.0 W, Area=1.62 m2.

Result: 12 panels max on 600 V (580.8 V); 29 panels for 8 kW (506 sq ft).

What Are the Published CEC Specifications for RECOM SILLIA RCM-285-6PB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for RECOM SILLIA RCM-285-6PB.

Official California Energy Commission (NREL SAM) test parameters for RECOM SILLIA RCM-285-6PB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 251.1 W (88.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.0 V / 8.14 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.59% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many RECOM SILLIA RCM-285-6PB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using RECOM SILLIA RCM-285-6PB (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 384 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 506 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 628 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This RECOM SILLIA Series?

All closely matched RECOM SILLIA wattages and cosmetic trims sharing the RECOM SILLIA RCM-285-6PB architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the RECOM SILLIA RCM-285-6PB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
RECOM SILLIA RCM-275-6PB 275.0 W 249.5 W 38.15 V 31.8 V 16.98%
RECOM SILLIA RCM-280-6PB 280.0 W 254.2 W 38.3 V 32.0 V 17.28%
RECOM SILLIA RCM-285-6PB 285.0 W 251.1 W 43.0 V 35.0 V 17.59%
RECOM SILLIA RCM-290-6PB 290.0 W 255.7 W 43.0 V 35.0 V 17.9%

How Many RECOM SILLIA RCM-285-6PB Modules Fit in a Cold-Weather String?

Maximum series module counts for RECOM SILLIA RCM-285-6PB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.0V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.95 V 12 panels 599.4 V 20 panels
-10 C (14 F) 48.4 V 12 panels 580.8 V 20 panels
0 C (32 F) 46.86 V 12 panels 562.3 V 21 panels
25 C (77 F STC) 43.0 V 13 panels 559.0 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to RECOM SILLIA RCM-285-6PB?

Alternative CEC solar modules from competing brands near RECOM SILLIA RCM-285-6PB (285.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP285-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP285-72
Anhui Rinengzhongtian Semiconductor Development
285.0 W Tie (0 W) 43.1 V 14.69% 89.3%
Anhui Rinengzhongtian Semiconductor Development QJM285-72
Anhui Rinengzhongtian Semiconductor Development
285.0 W Tie (0 W) 44.03 V 14.69% 89.8%
Advance Power API-M285
Advance Power
285.0 W Tie (0 W) 44.21 V 14.61% 89.1%
Advance Power API-P285
Advance Power
285.0 W Tie (0 W) 44.21 V 14.61% 90.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for RECOM SILLIA RCM-285-6PB?

Evaluate RECOM SILLIA RCM-285-6PB (285.0 W STC, 43.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), RECOM SILLIA RCM-285-6PB reaches 49.95 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (506 sq ft).
  • 2026 tax credit baseline: cash residential installs of RECOM SILLIA RCM-285-6PB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

RECOM SILLIA RCM-285-6PB 8 kW Residential Fit

Needs 29 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP285-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 251.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for RECOM SILLIA RCM-285-6PB by RECOM SILLIA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for RECOM SILLIA RCM-285-6PB?

Multiplying RECOM SILLIA RCM-285-6PB's 8.83 A short-circuit current by 1.56 equals 13.77 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can RECOM SILLIA RCM-285-6PB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 48.4 V cold Voc at 14 F and handles 8.83 A Isc; string inverters cap RECOM SILLIA RCM-285-6PB at 12 panels on 600 V.

Is RECOM SILLIA RCM-285-6PB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of RECOM SILLIA RCM-285-6PB rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.