REC Group REC460AA Pure-RXG is a 460.0 W STC (440.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 22.77% efficiency, 65.8 V Voc at 25 C, and 71.12 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 440.1 W
- Voc @ 25C
- 65.8 V
- Efficiency
- 22.77%
How Does REC Group REC460AA Pure-RXG Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC460AA Pure-RXG (Mono-c-Si) residential solar systems.
REC Group REC460AA Pure-RXG delivers 227.7 W/m2 (2.86 percentage points above 19.91% CEC median) and strong 95.7% PTC-to-STC heat retention (#47 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 72.64 V per unit, capping 600 V circuits at 8 panels. Compare specs directly with Heliene 96M460 (460.0 W).
Where Does REC Group REC460AA Pure-RXG Fall Across Listed CEC Models?
Comparison of REC Group REC460AA Pure-RXG (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define REC Group REC460AA Pure-RXG?
Relative ranking of REC Group REC460AA Pure-RXG across nameplate watts, 95.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for REC Group REC460AA Pure-RXG?
Summary of REC Group REC460AA Pure-RXG output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.77% Aperture Efficiency
Power density 227.7 W/m2 (2.86 percentage points above 19.91% CEC median). PTC/STC ratio: 95.7% (rank #47).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 71.12 V at -10 C (569.0 V string) and 72.64 V at -20 C (8 max).
18 Panels = 8,280 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,922 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 65.8 * (1 + (-0.231/100) * (-10 - 25)) = 71.12 V | OCPD = 1.56 * 8.88 = 13.85 A
Inputs from CEC Modules.csv for REC Group REC460AA Pure-RXG: Voc=65.8 V, beta_Voc=-0.231%/C, Isc=8.88 A, STC=460.0 W, Area=2.02 m2.
Result: 8 panels max on 600 V (569.0 V); 18 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for REC Group REC460AA Pure-RXG?
Complete CEC test sheet for REC Group REC460AA Pure-RXG including Isc (8.88 A), Voc (65.8 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 440.1 W (95.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 65.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 54.9 V / 8.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.231 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.77% (2.02 m2) | Array roof footprint density |
| Cell Count & Technology | 44 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC460AA Pure-RXG Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC460AA Pure-RXG.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 304 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 391 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 478 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Related REC Group power steps and black/silver trims consolidated into this REC Group REC460AA Pure-RXG series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC450AA Pure-RXG | 450.0 W | 430.4 W | 65.6 V | 54.3 V | 22.28% |
| REC Group REC460AA Pure-RXG | 460.0 W | 440.1 W | 65.8 V | 54.9 V | 22.77% |
How Many REC Group REC460AA Pure-RXG Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for REC Group REC460AA Pure-RXG (65.8 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 72.64 V | 8 panels | 581.1 V | 13 panels |
| -10 C (14 F) | 71.12 V | 8 panels | 569.0 V | 14 panels |
| 0 C (32 F) | 69.6 V | 8 panels | 556.8 V | 14 panels |
| 25 C (77 F STC) | 65.8 V | 9 panels | 592.2 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC460AA Pure-RXG?
Four comparable CEC modules such as Heliene 96M460 (460.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M460 Heliene |
460.0 W | Tie (0 W) | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +15.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | Tie (0 W) | 52.0 V | 20.09% | 93.1% |
| Heliene 144HC-460 Heliene |
460.0 W | Tie (0 W) | 51.26 V | 20.81% | 92.4% |
What Are the Design Limits and Best-Fit Uses for REC Group REC460AA Pure-RXG?
Evaluate REC Group REC460AA Pure-RXG (460.0 W STC, 65.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC460AA Pure-RXG reaches 72.64 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 391 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC460AA Pure-RXG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC460AA Pure-RXG 8 kW Residential Fit
Needs 18 modules (391 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M460.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 440.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC460AA Pure-RXG by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
How many REC Group REC460AA Pure-RXG panels fit on a 600 V winter solar string?
At -10 C (14 F), REC Group REC460AA Pure-RXG cold Voc rises from 65.8 V to 71.12 V (beta_Voc -0.231%/C), capping a 600 V string at 8 panels (569.0 V).
How much roof area does an 8 kW array of REC Group REC460AA Pure-RXG need?
An 8 kW DC system uses 18 REC Group REC460AA Pure-RXG modules (8,280 W STC / 7,922 W PTC), covering roughly 391 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does REC Group REC460AA Pure-RXG compare against Heliene 96M460?
REC Group REC460AA Pure-RXG outputs 460.0 W STC (65.8 V Voc, rank #5,199 of 21,677), while Heliene 96M460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)