REC Group REC460AA Pure-RX is a 460.0 W STC (438.8 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 22.77% efficiency, 65.3 V Voc at 25 C, and 70.63 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 438.8 W
- Voc @ 25C
- 65.3 V
- Efficiency
- 22.77%
How Does REC Group REC460AA Pure-RX Compare Against Peer CEC Listings?
Solar engineering breakdown for REC Group REC460AA Pure-RX: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC460AA Pure-RX stands 50.0 W above the 410.0 W Mono-c-Si median and strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,612-$2,533/yr in baseline US bill offset. Higher 65.3 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C).
Where Does REC Group REC460AA Pure-RX Fall Across Listed CEC Models?
Distribution marker showing REC Group REC460AA Pure-RX (460.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define REC Group REC460AA Pure-RX?
Dataset percentiles tracking REC Group REC460AA Pure-RX power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for REC Group REC460AA Pure-RX?
Benchmark highlights for REC Group REC460AA Pure-RX covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.77% Aperture Efficiency
Power density 227.7 W/m2 (2.86 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 70.63 V at -10 C (565.0 V string) and 72.15 V at -20 C (8 max).
18 Panels = 8,280 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,898 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 65.3 * (1 + (-0.233/100) * (-10 - 25)) = 70.63 V | OCPD = 1.56 * 8.88 = 13.85 A
Inputs from CEC Modules.csv for REC Group REC460AA Pure-RX: Voc=65.3 V, beta_Voc=-0.233%/C, Isc=8.88 A, STC=460.0 W, Area=2.02 m2.
Result: 8 panels max on 600 V (565.0 V); 18 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for REC Group REC460AA Pure-RX?
Official CEC datasheet figures for REC Group REC460AA Pure-RX (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 438.8 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 65.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 54.9 V / 8.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.77% (2.02 m2) | Array roof footprint density |
| Cell Count & Technology | 88 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC460AA Pure-RX Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many REC Group REC460AA Pure-RX modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 304 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 391 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 478 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Consolidated REC Group wattage variants sharing the REC Group REC460AA Pure-RX mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC450AA Pure-RX | 450.0 W | 429.1 W | 65.1 V | 54.3 V | 22.28% |
| REC Group REC455AA Pure-RX | 455.0 W | 434.0 W | 65.6 V | 54.6 V | 22.52% |
| REC Group REC460AA Pure-RX | 460.0 W | 438.8 W | 65.3 V | 54.9 V | 22.77% |
| REC Group REC465AA Pure-RX | 465.0 W | 443.7 W | 65.7 V | 55.2 V | 23.02% |
| REC Group REC470AA Pure-RX | 470.0 W | 448.6 W | 65.7 V | 55.4 V | 23.27% |
How Many REC Group REC460AA Pure-RX Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC460AA Pure-RX (70.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 72.15 V | 8 panels | 577.2 V | 13 panels |
| -10 C (14 F) | 70.63 V | 8 panels | 565.0 V | 14 panels |
| 0 C (32 F) | 69.1 V | 8 panels | 552.8 V | 14 panels |
| 25 C (77 F STC) | 65.3 V | 9 panels | 587.7 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC460AA Pure-RX?
Competing CEC solar panels closest to REC Group REC460AA Pure-RX in nameplate wattage and Voc, starting with Heliene 96M460.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M460 Heliene |
460.0 W | Tie (0 W) | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +15.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | Tie (0 W) | 52.0 V | 20.09% | 93.1% |
| Heliene 144HC-460 Heliene |
460.0 W | Tie (0 W) | 51.26 V | 20.81% | 92.4% |
What Are the Design Limits and Best-Fit Uses for REC Group REC460AA Pure-RX?
Evaluate REC Group REC460AA Pure-RX (460.0 W STC, 65.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC460AA Pure-RX reaches 72.15 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 391 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC460AA Pure-RX carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC460AA Pure-RX 8 kW Residential Fit
Needs 18 modules (391 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M460.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC460AA Pure-RX by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC460AA Pure-RX?
Multiplying REC Group REC460AA Pure-RX's 8.88 A short-circuit current by 1.56 equals 13.85 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can REC Group REC460AA Pure-RX pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 70.63 V cold Voc at 14 F and handles 8.88 A Isc; string inverters cap REC Group REC460AA Pure-RX at 8 panels on 600 V.
Is REC Group REC460AA Pure-RX eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC460AA Pure-RX rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)