REC Group REC405TP3SM 72 XV is a 405.0 W STC (379.0 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 48.6 V Voc at 25 C, and 53.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 379.0 W
- Voc @ 25C
- 48.6 V
- Efficiency
- 20.77%
How Does REC Group REC405TP3SM 72 XV Compare Against Peer CEC Listings?
Engineering position of REC Group REC405TP3SM 72 XV (405.0 W STC) vs. Aptos Solar Technology LLC DNA-144-MF23-405W {Blk} across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, REC Group REC405TP3SM 72 XV pairs strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677) with 48.6 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,580 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Aptos Solar Technology LLC DNA-144-MF23-405W {Blk} offers a 405.0 W alternative.
Where Does REC Group REC405TP3SM 72 XV Fall Across Listed CEC Models?
Plots REC Group REC405TP3SM 72 XV at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC405TP3SM 72 XV?
Benchmarks REC Group REC405TP3SM 72 XV on STC wattage, thermal PTC/STC retention, and 20.77 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for REC Group REC405TP3SM 72 XV?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC405TP3SM 72 XV by REC Group.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.77% Aperture Efficiency
Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.11 V at -10 C (584.2 V string) and 54.4 V at -20 C (11 max).
20 Panels = 8,100 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,580 W PTC; NEC 690.8 OCPD floor is 16.29 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.6 * (1 + (-0.265/100) * (-10 - 25)) = 53.11 V | OCPD = 1.56 * 10.44 = 16.29 A
Inputs from CEC Modules.csv for REC Group REC405TP3SM 72 XV: Voc=48.6 V, beta_Voc=-0.265%/C, Isc=10.44 A, STC=405.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (584.2 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for REC Group REC405TP3SM 72 XV?
Laboratory test ratings recorded for REC Group REC405TP3SM 72 XV (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 379.0 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.7 V / 9.72 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.77% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC405TP3SM 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC405TP3SM 72 XV.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 420 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 525 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Sibling wattage bins and frame colors grouped with REC Group REC405TP3SM 72 XV under REC Group to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC400TP3SM 72 XV | 400.0 W | 374.2 W | 48.2 V | 41.4 V | 20.51% |
| REC Group REC405TP3SM 72 XV | 405.0 W | 379.0 W | 48.6 V | 41.7 V | 20.77% |
How Many REC Group REC405TP3SM 72 XV Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for REC Group REC405TP3SM 72 XV (beta_Voc -0.265%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.4 V | 11 panels | 598.4 V | 18 panels |
| -10 C (14 F) | 53.11 V | 11 panels | 584.2 V | 18 panels |
| 0 C (32 F) | 51.82 V | 11 panels | 570.0 V | 19 panels |
| 25 C (77 F STC) | 48.6 V | 12 panels | 583.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC405TP3SM 72 XV?
Closest cross-brand CEC competitors to REC Group REC405TP3SM 72 XV matched near 405.0 W STC and 48.6 V Voc, led by Aptos Solar Technology LLC DNA-144-MF23-405W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF23-405W {Blk} Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 48.73 V | 20.13% | 90.8% |
| Aptos Solar Technology LLC DNA-144-MF23-405W {Wht} Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 48.73 V | 20.77% | 93.5% |
| AXITEC AC-405MH/144S AXITEC |
405.0 W | Tie (0 W) | 48.73 V | 20.45% | 93.5% |
| CertainTeed CT405HC00-04 CertainTeed |
405.0 W | Tie (0 W) | 48.73 V | 20.77% | 93.5% |
What Are the Design Limits and Best-Fit Uses for REC Group REC405TP3SM 72 XV?
Evaluate REC Group REC405TP3SM 72 XV (405.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC405TP3SM 72 XV reaches 54.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC405TP3SM 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC405TP3SM 72 XV 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF23-405W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC405TP3SM 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC405TP3SM 72 XV?
Multiplying REC Group REC405TP3SM 72 XV's 10.44 A short-circuit current by 1.56 equals 16.29 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC405TP3SM 72 XV pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.11 V cold Voc at 14 F and handles 10.44 A Isc; string inverters cap REC Group REC405TP3SM 72 XV at 11 panels on 600 V.
Is REC Group REC405TP3SM 72 XV eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC405TP3SM 72 XV rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)