Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC400TP2SM 72 XV BLK — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC400TP2SM 72 XV BLK is a 400.0 W STC (376.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.0 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
376.3 W
Voc @ 25C
49.0 V
Efficiency
20.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC400TP2SM 72 XV BLK Compare Against Peer CEC Listings?

Engineering position of REC Group REC400TP2SM 72 XV BLK (400.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-400-H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, REC Group REC400TP2SM 72 XV BLK pairs strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677) with 49.0 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,526 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-400-H offers a 400.0 W alternative.

Where Does REC Group REC400TP2SM 72 XV BLK Fall Across Listed CEC Models?

Plots REC Group REC400TP2SM 72 XV BLK at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC400TP2SM 72 XV BLK (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC400TP: 400.0 W

What Dataset Percentiles Define REC Group REC400TP2SM 72 XV BLK?

Benchmarks REC Group REC400TP2SM 72 XV BLK on STC wattage, thermal PTC/STC retention, and 20.54 aperture conversion efficiency against CEC peers.

REC Group REC400TP2SM 72 XV BLK Engineering BenchmarksPercentile comparison of REC Group REC400TP2SM 72 XV BLK wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention94.1%Module Efficiency20.54%

What Do the Dataset Ranks Show for REC Group REC400TP2SM 72 XV BLK?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC400TP2SM 72 XV BLK by REC Group.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.28 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.285/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 10.2 = 15.91 A

Inputs from CEC Modules.csv for REC Group REC400TP2SM 72 XV BLK: Voc=49.0 V, beta_Voc=-0.285%/C, Isc=10.2 A, STC=400.0 W, Area=1.947 m2.

Result: 11 panels max on 600 V (592.8 V); 20 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for REC Group REC400TP2SM 72 XV BLK?

Laboratory test ratings recorded for REC Group REC400TP2SM 72 XV BLK (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC400TP2SM 72 XV BLK.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 376.3 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.1 V / 9.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.285 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.54% (1.947 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC400TP2SM 72 XV BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (419 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC400TP2SM 72 XV BLK.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 314 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 419 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 524 sq ft $2,503 $4,232

How Many REC Group REC400TP2SM 72 XV BLK Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC400TP2SM 72 XV BLK (beta_Voc -0.285%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.0V and beta_Voc=-0.285%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.28 V 10 panels 552.8 V 18 panels
-10 C (14 F) 53.89 V 11 panels 592.8 V 18 panels
0 C (32 F) 52.49 V 11 panels 577.4 V 19 panels
25 C (77 F STC) 49.0 V 12 panels 588.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC400TP2SM 72 XV BLK?

Closest cross-brand CEC competitors to REC Group REC400TP2SM 72 XV BLK matched near 400.0 W STC and 49.0 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W +5.0 W 49.1 V 20.77% 93.0%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W
Dehui Solar Power (Vietnam) CoLtd
405.0 W +5.0 W 49.1 V 20.77% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC400TP2SM 72 XV BLK?

Evaluate REC Group REC400TP2SM 72 XV BLK (400.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400TP2SM 72 XV BLK reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC400TP2SM 72 XV BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC400TP2SM 72 XV BLK 8 kW Residential Fit

Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC400TP2SM 72 XV BLK by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC400TP2SM 72 XV BLK?

Multiplying REC Group REC400TP2SM 72 XV BLK's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC400TP2SM 72 XV BLK pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.89 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC400TP2SM 72 XV BLK at 11 panels on 600 V.

Is REC Group REC400TP2SM 72 XV BLK eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC400TP2SM 72 XV BLK rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.