REC Group REC400TP2SM 72 BLK is a 400.0 W STC (376.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.0 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 376.3 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 20.54%
How Does REC Group REC400TP2SM 72 BLK Compare Against Peer CEC Listings?
How REC Group REC Group REC400TP2SM 72 BLK handles rooftop heat (376.3 W PTC), 8 kW sizing, and cold winter string voltage.
REC Group builds the REC Group REC400TP2SM 72 BLK (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-400-H (400.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.91 A overcurrent floor served by a 20 A breaker.
Where Does REC Group REC400TP2SM 72 BLK Fall Across Listed CEC Models?
Where REC Group REC400TP2SM 72 BLK (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC400TP2SM 72 BLK?
Percentile placement of REC Group REC400TP2SM 72 BLK across power density (205.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for REC Group REC400TP2SM 72 BLK?
Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC400TP2SM 72 BLK specifications.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.54% Aperture Efficiency
Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.28 V at -20 C (10 max).
20 Panels = 8,000 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.285/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 10.2 = 15.91 A
Inputs from CEC Modules.csv for REC Group REC400TP2SM 72 BLK: Voc=49.0 V, beta_Voc=-0.285%/C, Isc=10.2 A, STC=400.0 W, Area=1.947 m2.
Result: 11 panels max on 600 V (592.8 V); 20 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for REC Group REC400TP2SM 72 BLK?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC400TP2SM 72 BLK.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 376.3 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.1 V / 9.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.285 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.54% (1.947 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC400TP2SM 72 BLK Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC400TP2SM 72 BLK (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 314 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 419 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 524 sq ft | $2,503 | $4,232 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
All closely matched REC Group wattages and cosmetic trims sharing the REC Group REC400TP2SM 72 BLK architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC400TP2SM 72 | 400.0 W | 376.3 W | 49.0 V | 41.1 V | 20.54% |
| REC Group REC400TP2SM 72 BLK | 400.0 W | 376.3 W | 49.0 V | 41.1 V | 20.54% |
How Many REC Group REC400TP2SM 72 BLK Modules Fit in a Cold-Weather String?
Maximum series module counts for REC Group REC400TP2SM 72 BLK from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.28 V | 10 panels | 552.8 V | 18 panels |
| -10 C (14 F) | 53.89 V | 11 panels | 592.8 V | 18 panels |
| 0 C (32 F) | 52.49 V | 11 panels | 577.4 V | 19 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC400TP2SM 72 BLK?
Alternative CEC solar modules from competing brands near REC Group REC400TP2SM 72 BLK (400.0 W), including Boviet Solar Technology Co Ltd BVM6612M-400-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | +5.0 W | 49.1 V | 20.77% | 93.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | +5.0 W | 49.1 V | 20.77% | 93.0% |
What Are the Design Limits and Best-Fit Uses for REC Group REC400TP2SM 72 BLK?
Evaluate REC Group REC400TP2SM 72 BLK (400.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400TP2SM 72 BLK reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC400TP2SM 72 BLK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC400TP2SM 72 BLK 8 kW Residential Fit
Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC400TP2SM 72 BLK by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC400TP2SM 72 BLK?
Multiplying REC Group REC400TP2SM 72 BLK's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC400TP2SM 72 BLK pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.89 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC400TP2SM 72 BLK at 11 panels on 600 V.
Is REC Group REC400TP2SM 72 BLK eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC400TP2SM 72 BLK rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)