REC Group REC400NP 72 — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC400NP 72 is a 400.0 W STC (374.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.54% efficiency, 49.4 V Voc at 25 C, and 54.0 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
374.2 W
Voc @ 25C
49.4 V
Efficiency
20.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC400NP 72 Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC400NP 72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 400.0 W STC and 374.2 W PTC, REC Group REC400NP 72 sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-400-H rates 400.0 W.

Where Does REC Group REC400NP 72 Fall Across Listed CEC Models?

Distribution marker showing REC Group REC400NP 72 (400.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC400NP 72 (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC400NP: 400.0 W

What Dataset Percentiles Define REC Group REC400NP 72?

Dataset percentiles tracking REC Group REC400NP 72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

REC Group REC400NP 72 Engineering BenchmarksPercentile comparison of REC Group REC400NP 72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention93.5%Module Efficiency20.54%

What Do the Dataset Ranks Show for REC Group REC400NP 72?

Benchmark highlights for REC Group REC400NP 72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.0 V at -10 C (594.0 V string) and 55.31 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,484 W PTC; NEC 690.8 OCPD floor is 16.22 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.266/100) * (-10 - 25)) = 54.0 V | OCPD = 1.56 * 10.4 = 16.22 A

Inputs from CEC Modules.csv for REC Group REC400NP 72: Voc=49.4 V, beta_Voc=-0.266%/C, Isc=10.4 A, STC=400.0 W, Area=1.947 m2.

Result: 11 panels max on 600 V (594.0 V); 20 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for REC Group REC400NP 72?

Official CEC datasheet figures for REC Group REC400NP 72 (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC400NP 72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 374.2 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.4 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.7 V / 9.84 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.54% (1.947 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC400NP 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC400NP 72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 314 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 419 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 524 sq ft $2,503 $4,232

How Many REC Group REC400NP 72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC400NP 72 (54.0 V at 14 F).

Computed from Voc=49.4V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.31 V 10 panels 553.1 V 18 panels
-10 C (14 F) 54.0 V 11 panels 594.0 V 18 panels
0 C (32 F) 52.69 V 11 panels 579.6 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC400NP 72?

Competing CEC solar panels closest to REC Group REC400NP 72 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC400NP 72?

Evaluate REC Group REC400NP 72 (400.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC400NP 72 reaches 55.31 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC400NP 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC400NP 72 8 kW Residential Fit

Needs 20 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC400NP 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC400NP 72 panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC400NP 72 cold Voc rises from 49.4 V to 54.0 V (beta_Voc -0.266%/C), capping a 600 V string at 11 panels (594.0 V).

How much roof area does an 8 kW array of REC Group REC400NP 72 need?

An 8 kW DC system uses 20 REC Group REC400NP 72 modules (8,000 W STC / 7,484 W PTC), covering roughly 419 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does REC Group REC400NP 72 compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?

REC Group REC400NP 72 outputs 400.0 W STC (49.4 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.