REC Group REC390AA Pure is a 390.0 W STC (371.3 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 21.79% efficiency, 48.6 V Voc at 25 C, and 52.56 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 371.3 W
- Voc @ 25C
- 48.6 V
- Efficiency
- 21.79%
How Does REC Group REC390AA Pure Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC390AA Pure (Mono-c-Si) residential solar systems.
Homeowners evaluating REC Group REC390AA Pure need 16 panels for 6 kW or 21 panels (405 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (405 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.233%/C) pushes open-circuit voltage to 52.56 V at 14 F and 53.7 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does REC Group REC390AA Pure Fall Across Listed CEC Models?
Comparison of REC Group REC390AA Pure (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define REC Group REC390AA Pure?
Relative ranking of REC Group REC390AA Pure across nameplate watts, 95.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for REC Group REC390AA Pure?
Summary of REC Group REC390AA Pure output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.79% Aperture Efficiency
Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.56 V at -10 C (578.2 V string) and 53.7 V at -20 C (11 max).
21 Panels = 8,190 W STC
Occupies 37.6 m2 (405 sq ft) producing 7,797 W PTC; NEC 690.8 OCPD floor is 15.9 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.6 * (1 + (-0.233/100) * (-10 - 25)) = 52.56 V | OCPD = 1.56 * 10.19 = 15.9 A
Inputs from CEC Modules.csv for REC Group REC390AA Pure: Voc=48.6 V, beta_Voc=-0.233%/C, Isc=10.19 A, STC=390.0 W, Area=1.79 m2.
Result: 11 panels max on 600 V (578.2 V); 21 panels for 8 kW (405 sq ft).
What Are the Published CEC Specifications for REC Group REC390AA Pure?
Complete CEC test sheet for REC Group REC390AA Pure including Isc (10.19 A), Voc (48.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 371.3 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 9.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.79% (1.79 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC390AA Pure Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC390AA Pure.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 308 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 405 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 501 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Related REC Group power steps and black/silver trims consolidated into this REC Group REC390AA Pure series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC380AA Pure | 380.0 W | 361.6 W | 48.4 V | 40.9 V | 21.23% |
| REC Group REC385AA Pure | 385.0 W | 366.5 W | 48.5 V | 41.2 V | 21.46% |
| REC Group REC390AA Pure | 390.0 W | 371.3 W | 48.6 V | 41.5 V | 21.79% |
| REC Group REC395AA Pure | 395.0 W | 376.2 W | 48.7 V | 41.8 V | 22.02% |
How Many REC Group REC390AA Pure Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for REC Group REC390AA Pure (48.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.7 V | 11 panels | 590.7 V | 18 panels |
| -10 C (14 F) | 52.56 V | 11 panels | 578.2 V | 19 panels |
| 0 C (32 F) | 51.43 V | 11 panels | 565.7 V | 19 panels |
| 25 C (77 F STC) | 48.6 V | 12 panels | 583.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC390AA Pure?
Four comparable CEC modules such as CSI Solar Co Ltd CS3U-390MS (390.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-390MS CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | +5.0 W | 48.7 V | 20.26% | 92.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | +5.0 W | 48.7 V | 20.68% | 92.5% |
| Boviet Solar Technology Co Ltd BVM6612M-385-H Boviet Solar Technology Co Ltd |
385.0 W | -5.0 W | 48.5 V | 19.85% | 93.1% |
What Are the Design Limits and Best-Fit Uses for REC Group REC390AA Pure?
Evaluate REC Group REC390AA Pure (390.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC390AA Pure reaches 53.7 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 405 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (405 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC390AA Pure carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC390AA Pure 8 kW Residential Fit
Needs 21 modules (405 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-390MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 371.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC390AA Pure by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
Why is REC Group REC390AA Pure PTC wattage (371.3 W) lower than STC (390.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 371.3 W PTC (95.2% retention) across REC Group REC390AA Pure's 1.79 m2 aperture.
Who should skip REC Group REC390AA Pure on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 REC Group REC390AA Pure panels (405 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-390MS.
What is the 1,000 V commercial string limit for REC Group REC390AA Pure?
On 1,000 V commercial inverters at -10 C (52.56 V cold Voc), REC Group REC390AA Pure fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting REC Group REC390AA Pure.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)