REC Group REC385NP 72 XV is a 385.0 W STC (359.9 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.77% efficiency, 48.9 V Voc at 25 C, and 53.45 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 359.9 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 19.77%
How Does REC Group REC385NP 72 XV Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC385NP 72 XV (Mono-c-Si) residential solar systems.
Homeowners evaluating REC Group REC385NP 72 XV need 16 panels for 6 kW or 21 panels (440 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (440 sq ft). Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 53.45 V at 14 F and 54.75 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does REC Group REC385NP 72 XV Fall Across Listed CEC Models?
Comparison of REC Group REC385NP 72 XV (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define REC Group REC385NP 72 XV?
Relative ranking of REC Group REC385NP 72 XV across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for REC Group REC385NP 72 XV?
Summary of REC Group REC385NP 72 XV output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.
19.77% Aperture Efficiency
Power density 197.7 W/m2 (0.14 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.45 V at -10 C (588.0 V string) and 54.75 V at -20 C (10 max).
21 Panels = 8,085 W STC
Occupies 40.9 m2 (440 sq ft) producing 7,558 W PTC; NEC 690.8 OCPD floor is 16.04 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.266/100) * (-10 - 25)) = 53.45 V | OCPD = 1.56 * 10.28 = 16.04 A
Inputs from CEC Modules.csv for REC Group REC385NP 72 XV: Voc=48.9 V, beta_Voc=-0.266%/C, Isc=10.28 A, STC=385.0 W, Area=1.947 m2.
Result: 11 panels max on 600 V (588.0 V); 21 panels for 8 kW (440 sq ft).
What Are the Published CEC Specifications for REC Group REC385NP 72 XV?
Complete CEC test sheet for REC Group REC385NP 72 XV including Isc (10.28 A), Voc (48.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 359.9 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.0 V / 9.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.77% (1.947 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC385NP 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC385NP 72 XV.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 335 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 440 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 545 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Related REC Group power steps and black/silver trims consolidated into this REC Group REC385NP 72 XV series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC375NP 72 XV | 375.0 W | 350.3 W | 48.1 V | 39.7 V | 19.26% |
| REC Group REC380NP 72 XV | 380.0 W | 355.1 W | 48.5 V | 39.8 V | 19.52% |
| REC Group REC385NP 72 XV | 385.0 W | 359.9 W | 48.9 V | 40.0 V | 19.77% |
| REC Group REC390NP 72 XV | 390.0 W | 364.6 W | 49.1 V | 40.2 V | 20.03% |
| REC Group REC395NP 72 XV | 395.0 W | 369.4 W | 49.3 V | 40.5 V | 20.29% |
How Many REC Group REC385NP 72 XV Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for REC Group REC385NP 72 XV (48.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.75 V | 10 panels | 547.5 V | 18 panels |
| -10 C (14 F) | 53.45 V | 11 panels | 588.0 V | 18 panels |
| 0 C (32 F) | 52.15 V | 11 panels | 573.6 V | 19 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC385NP 72 XV?
Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E385M72 EMMVEE Photovoltaic Power Private Limited |
385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| Boviet Solar Technology Co Ltd BVM6612M-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
What Are the Design Limits and Best-Fit Uses for REC Group REC385NP 72 XV?
Evaluate REC Group REC385NP 72 XV (385.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC385NP 72 XV reaches 54.75 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (440 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC385NP 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC385NP 72 XV 8 kW Residential Fit
Needs 21 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC385NP 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
Why is REC Group REC385NP 72 XV PTC wattage (359.9 W) lower than STC (385.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 359.9 W PTC (93.5% retention) across REC Group REC385NP 72 XV's 1.947 m2 aperture.
Who should skip REC Group REC385NP 72 XV on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 REC Group REC385NP 72 XV panels (440 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E385M72.
What is the 1,000 V commercial string limit for REC Group REC385NP 72 XV?
On 1,000 V commercial inverters at -10 C (53.45 V cold Voc), REC Group REC385NP 72 XV fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)