Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC385NP 72 XV is a 385.0 W STC (359.9 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.77% efficiency, 48.9 V Voc at 25 C, and 53.45 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
359.9 W
Voc @ 25C
48.9 V
Efficiency
19.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC385NP 72 XV Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC385NP 72 XV (Mono-c-Si) residential solar systems.

Homeowners evaluating REC Group REC385NP 72 XV need 16 panels for 6 kW or 21 panels (440 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (440 sq ft). Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 53.45 V at 14 F and 54.75 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does REC Group REC385NP 72 XV Fall Across Listed CEC Models?

Comparison of REC Group REC385NP 72 XV (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC385NP 72 XV (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC385NP: 385.0 W

What Dataset Percentiles Define REC Group REC385NP 72 XV?

Relative ranking of REC Group REC385NP 72 XV across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.

REC Group REC385NP 72 XV Engineering BenchmarksPercentile comparison of REC Group REC385NP 72 XV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention93.5%Module Efficiency19.77%

What Do the Dataset Ranks Show for REC Group REC385NP 72 XV?

Summary of REC Group REC385NP 72 XV output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,307

19.77% Aperture Efficiency

Power density 197.7 W/m2 (0.14 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.45 V at -10 C (588.0 V string) and 54.75 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,558 W PTC; NEC 690.8 OCPD floor is 16.04 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.9 * (1 + (-0.266/100) * (-10 - 25)) = 53.45 V | OCPD = 1.56 * 10.28 = 16.04 A

Inputs from CEC Modules.csv for REC Group REC385NP 72 XV: Voc=48.9 V, beta_Voc=-0.266%/C, Isc=10.28 A, STC=385.0 W, Area=1.947 m2.

Result: 11 panels max on 600 V (588.0 V); 21 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for REC Group REC385NP 72 XV?

Complete CEC test sheet for REC Group REC385NP 72 XV including Isc (10.28 A), Voc (48.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC385NP 72 XV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 359.9 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.0 V / 9.63 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.77% (1.947 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC385NP 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC385NP 72 XV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 335 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 440 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 545 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC385NP 72 XV series guide.

Sibling CEC listings grouped into the REC Group REC385NP 72 XV wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC375NP 72 XV 375.0 W 350.3 W 48.1 V 39.7 V 19.26%
REC Group REC380NP 72 XV 380.0 W 355.1 W 48.5 V 39.8 V 19.52%
REC Group REC385NP 72 XV 385.0 W 359.9 W 48.9 V 40.0 V 19.77%
REC Group REC390NP 72 XV 390.0 W 364.6 W 49.1 V 40.2 V 20.03%
REC Group REC395NP 72 XV 395.0 W 369.4 W 49.3 V 40.5 V 20.29%

How Many REC Group REC385NP 72 XV Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC385NP 72 XV (48.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.9V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.75 V 10 panels 547.5 V 18 panels
-10 C (14 F) 53.45 V 11 panels 588.0 V 18 panels
0 C (32 F) 52.15 V 11 panels 573.6 V 19 panels
25 C (77 F STC) 48.9 V 12 panels 586.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC385NP 72 XV?

Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E385M72
EMMVEE Photovoltaic Power Private Limited
385.0 W Tie (0 W) 48.9 V 19.32% 92.0%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC385NP 72 XV?

Evaluate REC Group REC385NP 72 XV (385.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC385NP 72 XV reaches 54.75 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (440 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC385NP 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC385NP 72 XV 8 kW Residential Fit

Needs 21 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC385NP 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

Why is REC Group REC385NP 72 XV PTC wattage (359.9 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 359.9 W PTC (93.5% retention) across REC Group REC385NP 72 XV's 1.947 m2 aperture.

Who should skip REC Group REC385NP 72 XV on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 REC Group REC385NP 72 XV panels (440 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E385M72.

What is the 1,000 V commercial string limit for REC Group REC385NP 72 XV?

On 1,000 V commercial inverters at -10 C (53.45 V cold Voc), REC Group REC385NP 72 XV fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.