Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC380NP2 — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC380NP2 is a 380.0 W STC (358.2 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 21.47% efficiency, 41.4 V Voc at 25 C, and 45.05 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
358.2 W
Voc @ 25C
41.4 V
Efficiency
21.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC380NP2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC380NP2 (Mono-c-Si) residential solar systems.

REC Group REC380NP2 delivers 214.7 W/m2 (1.56 percentage points above 19.91% CEC median) and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (419 sq ft). At -4 F (-20 C), string voltage climbs to 46.09 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with DualSun SAS DualSun 380M-120-01 (380.0 W).

Where Does REC Group REC380NP2 Fall Across Listed CEC Models?

Comparison of REC Group REC380NP2 (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC380NP2 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC380NP: 380.0 W

What Dataset Percentiles Define REC Group REC380NP2?

Relative ranking of REC Group REC380NP2 across nameplate watts, 94.3% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

REC Group REC380NP2 Engineering BenchmarksPercentile comparison of REC Group REC380NP2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention94.3%Module Efficiency21.47%

What Do the Dataset Ranks Show for REC Group REC380NP2?

Summary of REC Group REC380NP2 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,599

21.47% Aperture Efficiency

Power density 214.7 W/m2 (1.56 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.05 V at -10 C (585.6 V string) and 46.09 V at -20 C (13 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,880 W PTC; NEC 690.8 OCPD floor is 17.96 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.252/100) * (-10 - 25)) = 45.05 V | OCPD = 1.56 * 11.51 = 17.96 A

Inputs from CEC Modules.csv for REC Group REC380NP2: Voc=41.4 V, beta_Voc=-0.252%/C, Isc=11.51 A, STC=380.0 W, Area=1.77 m2.

Result: 13 panels max on 600 V (585.6 V); 22 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for REC Group REC380NP2?

Complete CEC test sheet for REC Group REC380NP2 including Isc (11.51 A), Voc (41.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC380NP2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 358.2 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.51 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.3 V / 10.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.252 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.47% (1.77 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC380NP2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC380NP2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 305 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 419 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 514 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC380NP2 series guide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the REC Group REC380NP2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC375NP2 375.0 W 353.4 W 41.3 V 35.0 V 21.19%
REC Group REC375NP2 Black 375.0 W 353.4 W 41.3 V 35.0 V 21.19%
REC Group REC380NP2 380.0 W 358.2 W 41.4 V 35.3 V 21.47%
REC Group REC380NP2 Black 380.0 W 358.2 W 41.4 V 35.3 V 21.47%

How Many REC Group REC380NP2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC380NP2 (41.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.4V and beta_Voc=-0.252%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.09 V 13 panels 599.2 V 21 panels
-10 C (14 F) 45.05 V 13 panels 585.6 V 22 panels
0 C (32 F) 44.01 V 13 panels 572.1 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC380NP2?

Four comparable CEC modules such as DualSun SAS DualSun 380M-120-01 (380.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W Tie (0 W) 41.3 V 21.47% 93.9%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W Tie (0 W) 40.94 V 20.54% 94.2%
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W +5.0 W 41.4 V 21.51% 93.2%
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W -5.0 W 41.2 V 20.95% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC380NP2?

Evaluate REC Group REC380NP2 (380.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC380NP2 reaches 46.09 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 419 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (419 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC380NP2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC380NP2 8 kW Residential Fit

Needs 22 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC380NP2 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC380NP2 panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC380NP2 cold Voc rises from 41.4 V to 45.05 V (beta_Voc -0.252%/C), capping a 600 V string at 13 panels (585.6 V).

How much roof area does an 8 kW array of REC Group REC380NP2 need?

An 8 kW DC system uses 22 REC Group REC380NP2 modules (8,360 W STC / 7,880 W PTC), covering roughly 419 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does REC Group REC380NP2 compare against DualSun SAS DualSun 380M-120-01?

REC Group REC380NP2 outputs 380.0 W STC (41.4 V Voc, rank #11,043 of 21,677), while DualSun SAS DualSun 380M-120-01 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.