REC Group REC375TP2SM 72 is a 375.0 W STC (352.3 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 19.26% efficiency, 48.0 V Voc at 25 C, and 52.79 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
352.3 W
Voc @ 25C
48.0 V
Efficiency
19.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC375TP2SM 72 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC375TP2SM 72 (Mono-c-Si) residential solar systems.

REC Group REC375TP2SM 72 delivers 192.6 W/m2 (0.65 percentage points below 19.91% CEC median) and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (461 sq ft). At -4 F (-20 C), string voltage climbs to 54.16 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6612M-375 (375.0 W).

Where Does REC Group REC375TP2SM 72 Fall Across Listed CEC Models?

Comparison of REC Group REC375TP2SM 72 (375.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC375TP2SM 72 (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC375TP: 375.0 W

What Dataset Percentiles Define REC Group REC375TP2SM 72?

Relative ranking of REC Group REC375TP2SM 72 across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.

REC Group REC375TP2SM 72 Engineering BenchmarksPercentile comparison of REC Group REC375TP2SM 72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention93.9%Module Efficiency19.26%

What Do the Dataset Ranks Show for REC Group REC375TP2SM 72?

Summary of REC Group REC375TP2SM 72 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,849

19.26% Aperture Efficiency

Power density 192.6 W/m2 (0.65 percentage points below 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.79 V at -10 C (580.7 V string) and 54.16 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,751 W PTC; NEC 690.8 OCPD floor is 15.54 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.0 * (1 + (-0.285/100) * (-10 - 25)) = 52.79 V | OCPD = 1.56 * 9.96 = 15.54 A

Inputs from CEC Modules.csv for REC Group REC375TP2SM 72: Voc=48.0 V, beta_Voc=-0.285%/C, Isc=9.96 A, STC=375.0 W, Area=1.947 m2.

Result: 11 panels max on 600 V (580.7 V); 22 panels for 8 kW (461 sq ft).

What Are the Published CEC Specifications for REC Group REC375TP2SM 72?

Complete CEC test sheet for REC Group REC375TP2SM 72 including Isc (9.96 A), Voc (48.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC375TP2SM 72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 352.3 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.96 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.1 V / 9.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.285 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.26% (1.947 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC375TP2SM 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC375TP2SM 72.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 335 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 461 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 566 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC375TP2SM 72 series guide.

Sibling CEC listings grouped into the REC Group REC375TP2SM 72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC375TP2SM 72 375.0 W 352.3 W 48.0 V 40.1 V 19.26%
REC Group REC375TP2SM 72 BLK 375.0 W 352.3 W 48.0 V 40.1 V 19.26%
REC Group REC380TP2SM 72 380.0 W 357.1 W 48.2 V 40.3 V 19.52%
REC Group REC380TP2SM 72 BLK 380.0 W 357.1 W 48.2 V 40.3 V 19.52%
REC Group REC385TP2SM 72 385.0 W 361.9 W 48.4 V 40.5 V 19.77%
REC Group REC385TP2SM 72 BLK 385.0 W 361.9 W 48.4 V 40.5 V 19.77%
REC Group REC390TP2SM 72 390.0 W 366.7 W 48.6 V 40.7 V 20.03%
REC Group REC390TP2SM 72 BLK 390.0 W 366.7 W 48.6 V 40.7 V 20.03%
REC Group REC395TP2SM 72 395.0 W 371.5 W 48.8 V 40.9 V 20.29%
REC Group REC395TP2SM 72 BLK 395.0 W 371.5 W 48.8 V 40.9 V 20.29%

How Many REC Group REC375TP2SM 72 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC375TP2SM 72 (48.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.0V and beta_Voc=-0.285%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.16 V 11 panels 595.8 V 18 panels
-10 C (14 F) 52.79 V 11 panels 580.7 V 18 panels
0 C (32 F) 51.42 V 11 panels 565.6 V 19 panels
25 C (77 F STC) 48.0 V 12 panels 576.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC375TP2SM 72?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612M-375 (375.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-375
Boviet Solar Technology Co Ltd
375.0 W Tie (0 W) 48.0 V 19.33% 92.4%
CertainTeed CT375M11-02
CertainTeed
375.0 W Tie (0 W) 47.85 V 19.93% 91.4%
AXITEC AC-375M/72S
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
AXITEC AC-375M/72V
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC375TP2SM 72?

Evaluate REC Group REC375TP2SM 72 (375.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC375TP2SM 72 reaches 54.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 461 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (461 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC375TP2SM 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC375TP2SM 72 8 kW Residential Fit

Needs 22 modules (461 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-375.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC375TP2SM 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC375TP2SM 72 panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC375TP2SM 72 cold Voc rises from 48.0 V to 52.79 V (beta_Voc -0.285%/C), capping a 600 V string at 11 panels (580.7 V).

How much roof area does an 8 kW array of REC Group REC375TP2SM 72 need?

An 8 kW DC system uses 22 REC Group REC375TP2SM 72 modules (8,250 W STC / 7,751 W PTC), covering roughly 461 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does REC Group REC375TP2SM 72 compare against Boviet Solar Technology Co Ltd BVM6612M-375?

REC Group REC375TP2SM 72 outputs 375.0 W STC (48.0 V Voc, rank #11,367 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-375 delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.