Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC330NP — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC330NP is a 330.0 W STC (309.2 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 20.5% efficiency, 41.0 V Voc at 25 C, and 44.77 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
309.2 W
Voc @ 25C
41.0 V
Efficiency
20.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC330NP Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC330NP: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC330NP stands 80.0 W below the 410.0 W Mono-c-Si median and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Sizing 6 kW (19 panels) to 10 kW (31 panels) yields $1,569-$2,560/yr in baseline US bill offset. Mid-range 41.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does REC Group REC330NP Fall Across Listed CEC Models?

Distribution marker showing REC Group REC330NP (330.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC330NP (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC330NP: 330.0 W

What Dataset Percentiles Define REC Group REC330NP?

Dataset percentiles tracking REC Group REC330NP power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

REC Group REC330NP Engineering BenchmarksPercentile comparison of REC Group REC330NP wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention93.7%Module Efficiency20.5%

What Do the Dataset Ranks Show for REC Group REC330NP?

Benchmark highlights for REC Group REC330NP covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,637

20.5% Aperture Efficiency

Power density 205.0 W/m2 (0.59 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.77 V at -10 C (582.0 V string) and 45.85 V at -20 C (13 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 40.2 m2 (433 sq ft) producing 7,730 W PTC; NEC 690.8 OCPD floor is 16.11 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.0 * (1 + (-0.263/100) * (-10 - 25)) = 44.77 V | OCPD = 1.56 * 10.33 = 16.11 A

Inputs from CEC Modules.csv for REC Group REC330NP: Voc=41.0 V, beta_Voc=-0.263%/C, Isc=10.33 A, STC=330.0 W, Area=1.61 m2.

Result: 13 panels max on 600 V (582.0 V); 25 panels for 8 kW (433 sq ft).

What Are the Published CEC Specifications for REC Group REC330NP?

Official CEC datasheet figures for REC Group REC330NP (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC330NP.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 309.2 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.6 V / 9.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.5% (1.61 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC330NP Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC330NP modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 329 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 433 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 537 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Consolidated REC Group wattage variants sharing the REC Group REC330NP mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the REC Group REC330NP wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC325NP 325.0 W 304.0 W 41.0 V 34.4 V 20.06%
REC Group REC325NP Black 325.0 W 303.5 W 40.7 V 34.4 V 20.06%
REC Group REC330NP 330.0 W 309.2 W 41.0 V 34.6 V 20.5%
REC Group REC330NP Black 330.0 W 308.3 W 41.0 V 34.6 V 20.37%
REC Group REC335NP 335.0 W 314.0 W 41.3 V 34.8 V 20.81%

How Many REC Group REC330NP Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC330NP (44.77 V at 14 F).

Computed from Voc=41.0V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.85 V 13 panels 596.1 V 21 panels
-10 C (14 F) 44.77 V 13 panels 582.0 V 22 panels
0 C (32 F) 43.7 V 13 panels 568.1 V 22 panels
25 C (77 F STC) 41.0 V 14 panels 574.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC330NP?

Competing CEC solar panels closest to REC Group REC330NP in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3K-330MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3K-330MS
CSI Solar Co Ltd
330.0 W Tie (0 W) 40.5 V 20.62% 93.2%
CertainTeed CT330HC11-04
CertainTeed
330.0 W Tie (0 W) 40.27 V 19.64% 90.8%
Boviet Solar Technology Co Ltd BVM6610M-330L-H
Boviet Solar Technology Co Ltd
330.0 W Tie (0 W) 41.9 V 19.76% 93.6%
Boviet Solar Technology Co Ltd BVM6610M-330-H
Boviet Solar Technology Co Ltd
330.0 W Tie (0 W) 41.95 V 20.25% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC330NP?

Evaluate REC Group REC330NP (330.0 W STC, 41.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC330NP reaches 45.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (433 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC330NP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC330NP 8 kW Residential Fit

Needs 25 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3K-330MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC330NP by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC330NP?

Multiplying REC Group REC330NP's 10.33 A short-circuit current by 1.56 equals 16.11 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC330NP pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.77 V cold Voc at 14 F and handles 10.33 A Isc; string inverters cap REC Group REC330NP at 13 panels on 600 V.

Is REC Group REC330NP eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC330NP rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.