Rayzon Solar Limited RS580144TGC is a 580.0 W STC (545.2 W PTC) Mono-c-Si solar module ranking #1,885 of 21,677 CEC listings (top 9.4%; higher than 90.6% of peers). It delivers 22.66% efficiency, 52.8 V Voc at 25 C, and 57.16 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 580.0 W
- PTC Wattage
- 545.2 W
- Voc @ 25C
- 52.8 V
- Efficiency
- 22.66%
How Does Rayzon Solar Limited RS580144TGC Compare Against Peer CEC Listings?
Engineering position of Rayzon Solar Limited RS580144TGC (580.0 W STC) vs. EMMVEE Photovoltaic Power Private Limited E580HCBT144-T across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Rayzon Solar Limited RS580144TGC pairs strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677) with 52.8 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,633 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer EMMVEE Photovoltaic Power Private Limited E580HCBT144-T offers a 580.0 W alternative.
Where Does Rayzon Solar Limited RS580144TGC Fall Across Listed CEC Models?
Plots Rayzon Solar Limited RS580144TGC at 580.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Rayzon Solar Limited RS580144TGC?
Benchmarks Rayzon Solar Limited RS580144TGC on STC wattage, thermal PTC/STC retention, and 22.66 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Rayzon Solar Limited RS580144TGC?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Rayzon Solar Limited RS580144TGC by Rayzon Solar Limited.
Top 9.4% STC Output
580.0 W STC (+195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.66% Aperture Efficiency
Power density 226.6 W/m2 (2.75 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.16 V at -10 C (571.6 V string) and 58.41 V at -20 C (10 max).
14 Panels = 8,120 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,633 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.8 * (1 + (-0.236/100) * (-10 - 25)) = 57.16 V | OCPD = 1.56 * 13.71 = 21.39 A
Inputs from CEC Modules.csv for Rayzon Solar Limited RS580144TGC: Voc=52.8 V, beta_Voc=-0.236%/C, Isc=13.71 A, STC=580.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (571.6 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Rayzon Solar Limited RS580144TGC?
Laboratory test ratings recorded for Rayzon Solar Limited RS580144TGC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 580.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 545.2 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.75 V / 12.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.66% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Rayzon Solar Limited RS580144TGC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Rayzon Solar Limited RS580144TGC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.38 kW | 303 sq ft | $1,597 | $2,700 |
| 8 kW Class | 14 | 8.12 kW | 386 sq ft | $2,032 | $3,437 |
| 10 kW Class | 18 | 10.44 kW | 496 sq ft | $2,613 | $4,418 |
How Many Rayzon Solar Limited RS580144TGC Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Rayzon Solar Limited RS580144TGC (beta_Voc -0.236%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.41 V | 10 panels | 584.1 V | 17 panels |
| -10 C (14 F) | 57.16 V | 10 panels | 571.6 V | 17 panels |
| 0 C (32 F) | 55.92 V | 10 panels | 559.2 V | 17 panels |
| 25 C (77 F STC) | 52.8 V | 11 panels | 580.8 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS580144TGC?
Closest cross-brand CEC competitors to Rayzon Solar Limited RS580144TGC matched near 580.0 W STC and 52.8 V Voc, led by EMMVEE Photovoltaic Power Private Limited E580HCBT144-T.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E580HCBT144-T EMMVEE Photovoltaic Power Private Limited |
580.0 W | Tie (0 W) | 51.47 V | 22.66% | 94.6% |
| AMPS Solar AMPS-585N-144SW AMPS Solar |
585.0 W | +5.0 W | 52.7 V | 22.85% | 94.9% |
| Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF Boviet Solar Technology Co Ltd |
585.0 W | +5.0 W | 52.61 V | 22.67% | 95.1% |
| Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG Boviet Solar Technology Co Ltd |
585.0 W | +5.0 W | 52.61 V | 22.67% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS580144TGC?
Evaluate Rayzon Solar Limited RS580144TGC (580.0 W STC, 52.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS580144TGC reaches 58.41 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS580144TGC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rayzon Solar Limited RS580144TGC 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E580HCBT144-T.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 545.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rayzon Solar Limited RS580144TGC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Rayzon Solar Limited RS580144TGC?
Multiplying Rayzon Solar Limited RS580144TGC's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Rayzon Solar Limited RS580144TGC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 57.16 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap Rayzon Solar Limited RS580144TGC at 10 panels on 600 V.
Is Rayzon Solar Limited RS580144TGC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Rayzon Solar Limited RS580144TGC rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)