Skip to main content
WireAndSun
Calculators
CEC PV Module

Rayzon Solar Limited RS560144MBC — CEC Solar Module Specifications

Manufacturer: Rayzon Solar Limited Registry: CEC Verified Engineering Specification

Rayzon Solar Limited RS560144MBC is a 560.0 W STC (526.4 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.88% efficiency, 50.22 V Voc at 25 C, and 54.16 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
560.0 W
PTC Wattage
526.4 W
Voc @ 25C
50.22 V
Efficiency
21.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Rayzon Solar Limited RS560144MBC Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Rayzon Solar Limited RS560144MBC (Mono-c-Si) residential solar systems.

Rayzon Solar Limited RS560144MBC delivers 218.8 W/m2 (1.97 percentage points above 19.91% CEC median) and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 55.28 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Elin Energy (Sirius PV) ELNSM72M-HC-560 (560.0 W).

Where Does Rayzon Solar Limited RS560144MBC Fall Across Listed CEC Models?

Comparison of Rayzon Solar Limited RS560144MBC (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Rayzon Solar Limited RS560144MBC (560.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRayzon Solar Limit: 560.0 W

What Dataset Percentiles Define Rayzon Solar Limited RS560144MBC?

Relative ranking of Rayzon Solar Limited RS560144MBC across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.

Rayzon Solar Limited RS560144MBC Engineering BenchmarksPercentile comparison of Rayzon Solar Limited RS560144MBC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage560.0 WPTC/STC Retention94.0%Module Efficiency21.88%

What Do the Dataset Ranks Show for Rayzon Solar Limited RS560144MBC?

Summary of Rayzon Solar Limited RS560144MBC output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,404 / 21,677

Top 11.8% STC Output

560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,395

21.88% Aperture Efficiency

Power density 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.16 V at -10 C (595.8 V string) and 55.28 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,400 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,896 W PTC; NEC 690.8 OCPD floor is 20.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.22 * (1 + (-0.224/100) * (-10 - 25)) = 54.16 V | OCPD = 1.56 * 13.43 = 20.95 A

Inputs from CEC Modules.csv for Rayzon Solar Limited RS560144MBC: Voc=50.22 V, beta_Voc=-0.224%/C, Isc=13.43 A, STC=560.0 W, Area=2.56 m2.

Result: 11 panels max on 600 V (595.8 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Rayzon Solar Limited RS560144MBC?

Complete CEC test sheet for Rayzon Solar Limited RS560144MBC including Isc (13.43 A), Voc (50.22 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Rayzon Solar Limited RS560144MBC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 560.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 526.4 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.22 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.2 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.224 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.88% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Rayzon Solar Limited RS560144MBC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Rayzon Solar Limited RS560144MBC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.16 kW 303 sq ft $1,542 $2,607
8 kW Class 15 8.4 kW 413 sq ft $2,102 $3,555
10 kW Class 18 10.08 kW 496 sq ft $2,523 $4,266

How Many Rayzon Solar Limited RS560144MBC Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Rayzon Solar Limited RS560144MBC (50.22 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.22V and beta_Voc=-0.224%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.28 V 10 panels 552.8 V 18 panels
-10 C (14 F) 54.16 V 11 panels 595.8 V 18 panels
0 C (32 F) 53.03 V 11 panels 583.3 V 18 panels
25 C (77 F STC) 50.22 V 11 panels 552.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS560144MBC?

Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM72M-HC-560 (560.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM72M-HC-560
Elin Energy (Sirius PV)
560.0 W Tie (0 W) 49.9 V 21.88% 94.4%
Elin Energy (Sirius PV) ELNSM72M-HC-LV-560
Elin Energy (Sirius PV)
560.0 W Tie (0 W) 49.9 V 21.88% 94.4%
Chint New Energy Technology Co Ltd CHSM72N-HC-560
Chint New Energy Technology Co Ltd
560.0 W Tie (0 W) 50.55 V 21.71% 94.6%
Bluesun Solar CoLtd BSM555M10-72HPH
Bluesun Solar CoLtd
555.0 W -5.0 W 50.08 V 21.42% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS560144MBC?

Evaluate Rayzon Solar Limited RS560144MBC (560.0 W STC, 50.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS560144MBC reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS560144MBC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Rayzon Solar Limited RS560144MBC 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM72M-HC-560.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 526.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Rayzon Solar Limited RS560144MBC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.

How many Rayzon Solar Limited RS560144MBC panels fit on a 600 V winter solar string?

At -10 C (14 F), Rayzon Solar Limited RS560144MBC cold Voc rises from 50.22 V to 54.16 V (beta_Voc -0.224%/C), capping a 600 V string at 11 panels (595.8 V).

How much roof area does an 8 kW array of Rayzon Solar Limited RS560144MBC need?

An 8 kW DC system uses 15 Rayzon Solar Limited RS560144MBC modules (8,400 W STC / 7,896 W PTC), covering roughly 413 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

How does Rayzon Solar Limited RS560144MBC compare against Elin Energy (Sirius PV) ELNSM72M-HC-560?

Rayzon Solar Limited RS560144MBC outputs 560.0 W STC (50.22 V Voc, rank #2,404 of 21,677), while Elin Energy (Sirius PV) ELNSM72M-HC-560 delivers 560.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.