Rayzon Solar Limited RS550144MBC is a 550.0 W STC (516.7 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.87 V Voc at 25 C, and 53.78 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 516.7 W
- Voc @ 25C
- 49.87 V
- Efficiency
- 21.48%
How Does Rayzon Solar Limited RS550144MBC Compare Against Peer CEC Listings?
How Rayzon Solar Limited Rayzon Solar Limited RS550144MBC handles rooftop heat (516.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Rayzon Solar Limited RS550144MBC exhibits 13.36 A short-circuit current, requiring a 20.84 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,737 of 21,677 (140.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.4 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.87 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Rayzon Solar Limited RS550144MBC Fall Across Listed CEC Models?
Where Rayzon Solar Limited RS550144MBC (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Rayzon Solar Limited RS550144MBC?
Percentile placement of Rayzon Solar Limited RS550144MBC across power density (214.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Rayzon Solar Limited RS550144MBC?
Four critical engineering numbers homeowners and solar installers check first when reviewing Rayzon Solar Limited RS550144MBC specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.48% Aperture Efficiency
Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.78 V at -10 C (591.6 V string) and 54.9 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,750 W PTC; NEC 690.8 OCPD floor is 20.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.87 * (1 + (-0.224/100) * (-10 - 25)) = 53.78 V | OCPD = 1.56 * 13.36 = 20.84 A
Inputs from CEC Modules.csv for Rayzon Solar Limited RS550144MBC: Voc=49.87 V, beta_Voc=-0.224%/C, Isc=13.36 A, STC=550.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (591.6 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Rayzon Solar Limited RS550144MBC?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Rayzon Solar Limited RS550144MBC.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 516.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.91 V / 12.83 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.224 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.48% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Rayzon Solar Limited RS550144MBC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Rayzon Solar Limited RS550144MBC (550.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |
How Many Rayzon Solar Limited RS550144MBC Modules Fit in a Cold-Weather String?
Maximum series module counts for Rayzon Solar Limited RS550144MBC from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.9 V | 10 panels | 549.0 V | 18 panels |
| -10 C (14 F) | 53.78 V | 11 panels | 591.6 V | 18 panels |
| 0 C (32 F) | 52.66 V | 11 panels | 579.3 V | 18 panels |
| 25 C (77 F STC) | 49.87 V | 12 panels | 598.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS550144MBC?
Alternative CEC solar modules from competing brands near Rayzon Solar Limited RS550144MBC (550.0 W), including Alexus Solar ALEX-550-B-72-S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Alexus Solar ALEX-550-B-72-S Alexus Solar |
550.0 W | Tie (0 W) | 49.84 V | 21.32% | 92.6% |
| Alexus Solar ALEX-550-W-72-S Alexus Solar |
550.0 W | Tie (0 W) | 49.84 V | 21.32% | 92.6% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW550M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
550.0 W | Tie (0 W) | 49.9 V | 28.95% | 95.3% |
| Exiom Solution S A EX545-144MH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.65% | 92.5% |
What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS550144MBC?
Evaluate Rayzon Solar Limited RS550144MBC (550.0 W STC, 49.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS550144MBC reaches 54.9 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS550144MBC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rayzon Solar Limited RS550144MBC 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Alexus Solar ALEX-550-B-72-S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 516.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rayzon Solar Limited RS550144MBC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Rayzon Solar Limited RS550144MBC PTC wattage (516.7 W) lower than STC (550.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 516.7 W PTC (93.9% retention) across Rayzon Solar Limited RS550144MBC's 2.56 m2 aperture.
Who should skip Rayzon Solar Limited RS550144MBC on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Rayzon Solar Limited RS550144MBC panels (413 sq ft) leave unusable roof gaps vs. Alexus Solar ALEX-550-B-72-S.
What is the 1,000 V commercial string limit for Rayzon Solar Limited RS550144MBC?
On 1,000 V commercial inverters at -10 C (53.78 V cold Voc), Rayzon Solar Limited RS550144MBC fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Rayzon Solar Limited RS550144MBC.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)